The effect of surgical titanium rods on proton therapy delivered for cervical bone tumors: experimental validation using an anthropomorphic phantom

被引:23
作者
Dietlicher, Isabelle [1 ]
Casiraghi, Margherita [1 ]
Ares, Carmen [1 ]
Bolsi, Alessandra [1 ]
Weber, Damien C. [1 ,2 ]
Lomax, Antony J. [1 ,3 ]
Albertini, Francesca [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, CH-5232 Villigen, Switzerland
[2] Univ Bern, Univ Hosp Bern, Dept Radiooncol, Bern, Switzerland
[3] ETH, Swiss Inst Technol, Dept Phys, Zurich, Switzerland
关键词
proton radiotherapy; metal implants; phantom; IMPT; RADIOCHROMIC FILM DOSIMETRY; IMPT TREATMENT PLANS; EBT3; FILMS; RANGE UNCERTAINTIES; DOSE CALCULATION; GAFCHROMIC EBT2; VERIFICATION; PHOTON; ELECTRON; IMPACT;
D O I
10.1088/0031-9155/59/23/7181
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To investigate the effect of metal implants in proton radiotherapy, dose distributions of different, clinically relevant treatment plans have been measured in an anthropomorphic phantom and compared to treatment planning predictions. The anthropomorphic phantom, which is sliced into four segments in the cranio-caudal direction, is composed of tissue equivalent materials and contains a titanium implant in a vertebral body in the cervical region. GafChromic (R) films were laid between the different segments to measure the 2D delivered dose. Three different four-field plans have then been applied: a Single-Field-Uniform-Dose (SFUD) plan, both with and without artifact correction implemented, and an Intensity-Modulated-Proton-Therapy (IMPT) plan with the artifacts corrected. For corrections, the artifacts were manually outlined and the Hounsfield Units manually set to an average value for soft tissue. Results show a surprisingly good agreement between prescribed and delivered dose distributions when artifacts have been corrected, with > 97% and 98% of points fulfilling the gamma criterion of 3%/3 mm for both SFUD and the IMPT plans, respectively. In contrast, without artifact corrections, up to 18% of measured points fail the gamma criterion of 3%/3 mm for the SFUD plan. These measurements indicate that correcting manually for the reconstruction artifacts resulting from metal implants substantially improves the accuracy of the calculated dose distribution.
引用
收藏
页码:7181 / 7194
页数:14
相关论文
共 38 条
  • [1] Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertainties
    Albertini, F.
    Casiraghi, M.
    Lorentini, S.
    Rombi, B.
    Lomax, A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) : 4415 - 4431
  • [2] Albertini F, 2006, ADVANTAGE USING MVCT
  • [3] Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies
    Arjomandy, Bijan
    Tailor, Ramesh
    Anand, Aman
    Sahoo, Narayan
    Gillin, Michael
    Prado, Karl
    Vicic, Milos
    [J]. MEDICAL PHYSICS, 2010, 37 (05) : 1942 - 1947
  • [4] Dose perturbations and image artifacts caused by carbon-coated ceramic and stainless steel fiducials used in proton therapy for prostate cancer
    Cheung, Joey
    Kudchadker, Rajat J.
    Zhu, X. Ronald
    Lee, Andrew K.
    Newhauser, Wayne D.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (23) : 7135 - 7147
  • [5] PHASE II STUDY OF HIGH-DOSE PHOTON/PROTON RADIOTHERAPY IN THE MANAGEMENT OF SPINE SARCOMAS
    DeLaney, Thomas F.
    Liebsch, Norbert J.
    Pedlow, Francis X.
    Adams, Judith
    Dean, Susan
    Yeap, Beow Y.
    McManus, Patricia
    Rosenberg, Andrew E.
    Nielsen, G. Petur
    Harmon, David C.
    Spiro, Ira J.
    Raskin, Kevin A.
    Suit, Herman D.
    Yoon, Sam S.
    Hornicek, Francis J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (03): : 732 - 739
  • [6] Under-response correction for EBT3 films in the presence of proton spread out Bragg peaks
    Fiorini, F.
    Kirby, D.
    Thompson, J.
    Green, S.
    Parker, D. J.
    Jones, B.
    Hill, M. A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 454 - 461
  • [7] Minimax optimization for handling range and setup uncertainties in proton therapy
    Fredriksson, Albin
    Forsgren, Anders
    Hardemark, Bjorn
    [J]. MEDICAL PHYSICS, 2011, 38 (03) : 1672 - 1684
  • [8] The impact of dental metal artifacts on head and neck IMRT dose distributions
    Kim, Yusung
    Tome, Wolfgang A.
    Bal, Matthieu
    McNutt, Todd R.
    Spies, Lothar
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 79 (02) : 198 - 202
  • [9] MICROSCOPIC GOLD PARTICLE-BASED FIDUCIAL MARKERS FOR PROTON THERAPY OF PROSTATE CANCER
    Lim, Young Kyung
    Kwak, Jungwon
    Kim, Dong Wook
    Shin, Dongho
    Yoon, Myonggeun
    Park, Soah
    Kim, Jin Sung
    Ahn, Sung Hwan
    Shin, Jungwook
    Lee, Se Byeong
    Park, Sung Yong
    Pyo, Hong Ryeol
    Kim, Dae Yong
    Cho, Kwan Ho
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 74 (05): : 1609 - 1616
  • [10] Intensity modulation methods for proton radiotherapy
    Lomax, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (01) : 185 - 205