Comparison of LAM-ICP-MS and micro-PIXE results for palladium and rhodium in selected samples of Noril'sk and Talnakh sulfides

被引:51
作者
Cabri, LJ
Sylvester, PJ
Tubrett, MN
Peregoedova, A
Laflamme, JHG
机构
[1] Canada Ctr Mineral & Energy Technol, Ottawa, ON K1A 0G1, Canada
[2] Mem Univ Newfoundland, Dept Earth Sci, St Johns, NF A1B 3X5, Canada
[3] Carleton Univ, Dept Earth Sci, Ottawa, ON K1S 5B6, Canada
[4] Russian Acad Sci, Inst Mineral & Petrog, Novosibirsk 630090, Russia
[5] Canada Ctr Mineral & Energy Technol, Min & Mineral Sci Labs, Ottawa, ON K1A 0G1, Canada
关键词
laser-ablation microprobe; ICP-MS; micro-PIXE; electron-probe micro-analysis; PGE standards; synthesis; sulfide minerals; palladium; rhodium; ruthenium; Noril'sk; Talnakh; Russia;
D O I
10.2113/gscanmin.41.2.321
中图分类号
P57 [矿物学];
学科分类号
070901 ;
摘要
Comparisons of PGE measurements by laser-ablation microprobe (LAM-ICP-MS) with micro-PIXE analyses on the same sulfide grains were made in Order to assess data quality. Pyrrhotite, pentlandite and chalcopyrite from a few samples of disseminated ores of the Noril'sk I intrusion and massive ore from the Talnakh deposit, Russia, were analyzed for Pd and Rh by micro-PIXE and for all PGE by LAM-ICP-MS. Micro-PIXE analyses employed focused proton beams of 8 x 15 mum for grains in heavy-mineral separates and 15 x 20 mum for grains in hand samples. These represent analyzed volumes of about 2,350 mum(3) in pyrrhotite and 5,900 mum(3) for Pd in pentlandite. LAM analyses were performed with a focused, 266-nm laser beam fired at 0.3 mJ/pulse and 10 Hz, resulting in 35-40 pm spots and analyzed volumes of about 85,000 mum(3). Fused pyrrhotite standards separately doped with Pd, Ru, and Rh were synthesized for LAM-ICP-MS, and calibrated against sintered pyrrhotite PGE standards of Ballhaus & Sylvester (2000). The level of Pd, Ru and Rh varies by similar to4 to 9% (l(T) in the fused pyrrhotite standards at a 50-mum sampling scale. The LAM and micro-PIXE results for the natural sulfides are quite comparable, with the large majority of determinations failing within 33% of each other for both Pd and Rh on the same spot. This agreement is considered encouraging for use of the LAM-ICP-MS for trace PGE analysis, considering the large differences in volumes analyzed, and in probable trace-element heterogeneity in the grains and standards. The reasonable concordance of most Pd and Rh results by LAM-ICP-MS and micro-PIXE indicates the potential of the LAM-ICP-MS technique. LAM analyses of the natural sulfides for Pt, Ir and Os were made using the standards of Ballhaus & Sylvester (2000). Platinum is more enriched in pentlandite (n = 10) than in pyrrhotite (3.2 +/- 1.2 versus 0.73 +/- 0.60 ppm) from Noril'sk (MP6-97), but Ir(0.94 +/- 0.32 versus 1.38 +/- 0.13 ppm) is only slightly higher in pyrrhotite (n = 10), whereas Os (similar to0.5 ppm) is comparably enriched in both minerals. Noril'sk chalcopyrite contains trivial amounts of all PGE except Pd (6.6-15 ppm).
引用
收藏
页码:321 / 329
页数:9
相关论文
共 17 条
[1]   Non-chondritic distribution of the highly siderophile elements in mantle sulphides [J].
Alard, O ;
Griffin, WL ;
Lorand, JP ;
Jackson, SE ;
O'Reilly, SY .
NATURE, 2000, 407 (6806) :891-894
[2]   Noble metal enrichment processes in the Merensky Reef, Bushveld Complex [J].
Ballhaus, C ;
Sylvester, P .
JOURNAL OF PETROLOGY, 2000, 41 (04) :545-561
[3]  
Cabri L.J., 1998, MINERAL ASS CAN SHOR, P181
[4]  
Cabri LJ, 2002, T I MIN METALL B, V111, pB15
[5]  
CABRI LJ, 1998, 98070 CANMET MMSL
[6]   Determination of the precious metals in milligram samples of sulfides and oxides using inductively coupled plasma mass spectrometry after ion exchange preconcentration [J].
Chen, ZX ;
Fryer, BJ ;
Longerich, HP ;
Jackson, SE .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :805-809
[7]  
Distler V.V., 1994, P SUDBURY NORILSK S, P243
[8]  
Distler VV, 1999, GEOL ORE DEPOSIT+, V41, P214
[9]  
GENKIN AD, 1968, PGM THEIR ASS NORILS
[10]  
JACKSON SE, 1992, CAN MINERAL, V30, P1049