A mechanistic model of critical heat flux under subcooled flow boiling conditions for application to one- and three-dimensional computer codes

被引:16
作者
Le Corre, Jean-Marie [1 ,2 ]
Yao, Shi-Chune [2 ]
Amon, Cristina H. [2 ,3 ]
机构
[1] Westinghouse Elect Sweden AB, S-72163 Vasteras, Sweden
[2] Carnegie Mellon Univ, Dept Mech Engn, Pittsburgh, PA 15213 USA
[3] Univ Toronto, Fac Engn & Appl Sci, Toronto, ON M5S 1A4, Canada
基金
美国安德鲁·梅隆基金会;
关键词
WATER;
D O I
10.1016/j.nucengdes.2008.12.007
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Based on a review of visual observations at or near critical heat flux (CHF) under subcooled flow boiling conditions and consideration of CHF triggering mechanisms, presented in a companion paper [Le Corre, J.M., Yao, S.C., Amon, C.H., 2010. Two-phase flow regimes and mechanisms of critical heat flux under subcooled flow boiling conditions. Nucl. Eng. Des.], a model using a two-dimensional transient thermal analysis of the heater undergoing nucleation was developed to mechanistically predict CHF in the case of a bubbly flow regime. The model simulates the spatial and temporal heater temperature variations during nucleation at the wall, accounting for the stochastic nature of the boiling phenomena. It is postulated that a high local wall superheat occurring underneath a nucleating bubble at the time of bubble departure can prevent wall rewetting at CHF (Leidenfrost effect). The model has also the potential to evaluate the post-DNB heater temperature up to the point of heater melting. Validation of the proposed model was performed using detailed measured wall boiling parameters near CHF, thereby bypassing most needed constitutive relations. It was found that under limiting nucleation conditions: a peak wall temperature at the time of bubble departure can be reached at CHF preventing wall cooling by quenching. The simulations show that the resulting dry patch can survive the surrounding quenching events, preventing further nucleation and leading to a fast heater temperature increase. The model was applied at CHF conditions in simple geometry coupled with one-dimensional and three dimensional (CFD) codes. It was found that, within the range where CHF occurs under bubbly flow conditions (as defined in Le Corre et al., this issue), the local wall superheat underneath nucleating bubbles is predicted to reach the Leidenfrost temperature. However, a better knowledge of statistical variations in wall boiling parameters would be necessary to correctly capture the CHF trends with mass flux (or Weber number). (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:235 / 244
页数:10
相关论文
共 19 条
[1]   CFD prediction of flow and phase distribution in fuel assemblies with spacers [J].
Anglart, H ;
Nylund, O ;
Kurul, N ;
Podowski, MZ .
NUCLEAR ENGINEERING AND DESIGN, 1997, 177 (1-3) :215-228
[2]  
Bartel M D., 1999, Experimental investigation of subcooled boiling
[3]  
Bricard P., 1997, Multiphase Science and Technology, V9, P329
[4]   Burnout in subcooled flow boiling of water. A visual experimental study [J].
Celata, GP ;
Cumo, M ;
Mariani, A ;
Zummo, G .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2000, 39 (9-11) :896-908
[5]   A PHOTOGRAPHIC STUDY OF POOL BOILING IN THE REGION OF THE CRITICAL HEAT FLUX [J].
COLE, R .
AICHE JOURNAL, 1960, 6 (04) :533-538
[6]  
DEBORTOLI RA, 1958, WAPD188 AEC
[7]   SUBCOOLED FLOW BOILING AT HIGH HEAT-FLUX [J].
DELVALLE, VH ;
KENNING, DBR .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (10) :1907-1920
[8]  
GROENEVELD DC, 1995, NUCL ENG DES, V163, P1
[9]  
Ishii M., 1976, INT J MULTIPHAS FLOW, V3, P197, DOI DOI 10.1016/0301-9322(76)90008-2
[10]   Predicting stochastic features of vapor bubble detachment in flow boiling [J].
Klausner, JF ;
Mei, R ;
Zeng, LZ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (15) :3547-3552