Total arterial compliance estimated by stroke volume to aortic pulse pressure ratio in humans

被引:350
作者
Chemla, D
Hébert, JL
Coirault, C
Zamani, K
Suard, I
Colin, P
Lecarpentier, Y
机构
[1] Ecole Polytech, Ensta, Loa, INSERM,U451, F-91125 Palaiseau, France
[2] Univ Paris 11, Hop Bicetre, Serv Physiol Cardioresp, F-94275 Le Kremlin Bicetre, France
[3] Hop Antoine Beclere, Serv Cardiol, F-92141 Clamart, France
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1998年 / 274卷 / 02期
关键词
heart period; ventricular-arterial coupling; wave reflection;
D O I
10.1152/ajpheart.1998.274.2.H500
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
On the basis of the windkessel model, the stroke volume-to-aortic pulse pressure ratio (SV/PP) has been proposed as an estimate of total arterial compliance, but recent studies have questioned this approximation. Aortic pressure was obtained at rest in 31 adults undergoing cardiac catheterization (47 +/- 14 yr): controls (n = 7), patients with dilated cardiomyopathy (n = 10), and patients with other cardiac diseases (n = 14). me calculated PP, mean aortic pressure (MAoP), heart period (T), SV (thermodilution cardiac output/ heart rate), total peripheral resistance (R), total arterial compliance estimated by area method (C-area), and the time constant of aortic pressure decay in diastole (RCarea). In the overall population (n = 31), there was no significant difference between SV/PP and C-area. SV/PP was linearly related to C-area (SV/PP = 0.99C(area) + 0.05; r = 0.98; P < 0,001); the slope and intercept did not differ fr om unity and zero, respectively. Similar results were obtained in the three subgroups. These results implied that PP/MAoP and T/RCarea, were proportionally related (T/RCarea = 1.18PP/MAoP - 0.07; r = 0.96; P < 0.001). We conclude that for humans at rest reliable estimate of C-area and 2) T normalized by the time constant of aortic pressure decay in diastole was proportionally related to PP/MAoP. This last relationship could be considered an aspect of the coupling between the left ventricle and its load.
引用
收藏
页码:H500 / H505
页数:6
相关论文
共 39 条
  • [1] ALICANDRI CL, 1982, CLIN EXP HYPERTENS T, V7, P1073
  • [2] ELASTIC PROPERTIES AND WINDKESSEL FUNCTION OF THE HUMAN AORTA
    BELZ, GG
    [J]. CARDIOVASCULAR DRUGS AND THERAPY, 1995, 9 (01) : 73 - 83
  • [3] CAROLL JD, 1991, J CLIN INVEST, V87, P1002
  • [4] Matching dicrotic notch and mean pulmonary artery pressures: Implications for effective arterial elastance
    Chemla, D
    Hebert, JL
    Coirault, C
    Salmeron, S
    Zamani, K
    Lecarpentier, Y
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1996, 271 (04): : H1287 - H1295
  • [5] CHEMLA D, 1996, J MOL CELL CARDIOL, V28, pA252
  • [6] PULSATILE VERSUS STEADY COMPONENT OF BLOOD-PRESSURE - A CROSS-SECTIONAL ANALYSIS AND A PROSPECTIVE ANALYSIS ON CARDIOVASCULAR MORTALITY
    DARNE, B
    GIRERD, X
    SAFAR, M
    CAMBIEN, F
    GUIZE, L
    [J]. HYPERTENSION, 1989, 13 (04) : 392 - 400
  • [7] ATHEROSCLEROSIS COMPLICATING CHRONIC HYPERTENSION
    DUSTAN, HP
    [J]. CIRCULATION, 1974, 50 (05) : 871 - 879
  • [8] MATCHING BETWEEN VENTRICLE AND ARTERIAL LOAD - AN EVOLUTIONARY PROCESS
    ELZINGA, G
    WESTERHOF, N
    [J]. CIRCULATION RESEARCH, 1991, 68 (06) : 1495 - 1500
  • [9] HEMODYNAMIC CORRELATES OF ARTERIAL COMPLIANCE
    FERGUSON, JJ
    RANDALL, OS
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1986, 12 (06): : 376 - 380
  • [10] Frank O, 1920, Z BIOL-MUNICH, V71, P255