Peripheral Nerve Diffusion Tensor Imaging Interreader and Test-retest Reliability as Quantified by the Standard Error of Measurement

被引:8
|
作者
Preisner, Fabian [1 ]
Baeumer, Philipp [1 ,2 ]
Wehrstein, Michaela [3 ]
Friedmann-Bette, Birgit [3 ]
Hackbusch, Matthes [4 ]
Heiland, Sabine [1 ]
Bendszus, Martin [1 ]
Kronlage, Moritz [1 ]
机构
[1] Heidelberg Univ Hosp, Dept Neuroradiol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Ctr Radiol Dialog, Vinzenz von Paul Str 8, D-84503 Altotting, Germany
[3] Heidelberg Univ Hosp, Dept Sports Med Internal Med 7, Med Clin, Neuenheimer Feld 410, D-69120 Heidelberg, Germany
[4] Heidelberg Univ, Inst Med Biometry & Informat, Neuenheimer Feld 130-3, D-69120 Heidelberg, Germany
关键词
Diffusion tensor imaging; Magnetic resonance imaging; Peripheral nervous system; Reference values; Reproducibility of results; INTRACLASS CORRELATION-COEFFICIENTS; MAGNETIC-RESONANCE NEUROGRAPHY; MEDIAN NERVE; FIBER TRACTOGRAPHY; MR NEUROGRAPHY; FRACTIONAL ANISOTROPY; DIAGNOSTIC-ACCURACY; TUNNEL; NEUROPATHY; AGREEMENT;
D O I
10.1007/s00062-019-00859-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Diffusion tensor imaging (DTI) is increasingly being used in magnetic resonance neurography (MRN). The purpose of this study was to determine the interreader and test-retest reliability of peripheral nerve DTI in MRN with focus on the sciatic nerve. Methods In this prospective study 27 healthy volunteers each underwent 3 scans of a short DTI protocol on separate days consisting of a T2-weighted turbo spin-echo and single-shot DTI sequence of the sciatic nerve of the dominant leg. The DTI parameters fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) were obtained after manual nerve segmentation by two independent readers. Intraclass correlation coefficients (ICC), standard error of measurement (SEM), and Bland-Altman plots were calculated as measures for both interreader and test-retest agreement for all readout parameters. Results The mean +/- standard deviation was 0.507 +/- 0.05 for FA, 1308.5 +/- 162.4x 10(-6)mm(2)/s for MD, 905.6 +/- 145.4x10(-6)mm(2)/s for RD and 2114.1 +/- 219.2x 10(-6)mm(2)/s for AD. The SEM for FA was 0.02 for interreader and test-retest agreement, the SEM for MD, RD, and AD ranged between 46.2x 10(-6)mm(2)/s (RD) and 70.1x 10(-6)mm(2)/s (AD) for interreader reliability and between 45.9x 10(-6)mm(2)/s (RD) and 70.1x 10(-6)mm(2)/s (AD) for test-retest reliability. The ICC for interreader reliability of DTI parameters ranged between 0.81 and 0.92 and ICC for test-retest reliability between 0.76 and 0.91. Conclusion Peripheral nerve DTI of the sciatic nerve is reliable and reproducible. The measures presented here may serve as first orientation values of measurement accuracy when interpreting parameters of sciatic nerve DTI.
引用
收藏
页码:679 / 689
页数:11
相关论文
共 50 条
  • [41] Evaluation of peripheral nerve acute crush injury in rabbits: comparison among diffusion kurtosis imaging, diffusion tensor imaging and electromyography
    Qi Wan
    Yudong Yu
    Yingying Bao
    Jianfeng Hu
    Peng Wang
    Yu Peng
    Xiaoying Xia
    Yuting Liao
    Jieqiong Liu
    Xiaobin Xie
    Xinchun Li
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2022, 35 : 291 - 299
  • [42] Evaluation of peripheral nerve acute crush injury in rabbits: comparison among diffusion kurtosis imaging, diffusion tensor imaging and electromyography
    Wan, Qi
    Yu, Yudong
    Bao, Yingying
    Hu, Jianfeng
    Wang, Peng
    Peng, Yu
    Xia, Xiaoying
    Liao, Yuting
    Liu, Jieqiong
    Xie, Xiaobin
    Li, Xinchun
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2022, 35 (02) : 291 - 299
  • [43] Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T
    By, Samantha
    Smith, Alex K.
    Dethrage, Lindsey M.
    Lyttle, Bailey D.
    Landman, Bennett A.
    Creasy, Jeffrey L.
    Pawate, Siddharama
    Smith, Seth A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (06) : 1608 - 1618
  • [44] Test-retest reliability of a novel method for trunk position sense measurement in older adults with and without hyperkyphosis
    Keshavarzi, Fatemeh
    Azadinia, Fatemeh
    Talebian, Saeed
    Rasouli, Omid
    JOURNAL OF BODYWORK AND MOVEMENT THERAPIES, 2024, 40 : 1302 - 1308
  • [45] Measurement of morphological and physiological skin properties in aged care residents: a test-retest reliability pilot study
    Rayner, Robyn
    Carville, Keryln
    Leslie, Gavin
    Dhaliwal, Satvinder S.
    INTERNATIONAL WOUND JOURNAL, 2017, 14 (02) : 420 - 429
  • [46] TEST-RETEST RELIABILITY OF HANDGRIP STRENGTH MEASUREMENT USING A HYDRAULIC HAND DYNAMOMETER IN PATIENTS WITH CERVICAL RADICULOPATHY
    Savva, Christos
    Giakas, Giannis
    Efstathiou, Michalis
    Karagiannis, Christos
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2014, 37 (03) : 206 - 210
  • [47] Test-Retest and Between-Device Reliability of Vmaxpro IMU at Hip and Ankle for Vertical Jump Measurement
    Villalon-Gasch, Lamberto
    Jimenez-Olmedo, Jose M.
    Olaya-Cuartero, Javier
    Pueo, Basilio
    SENSORS, 2023, 23 (04)
  • [48] Diffusion tensor imaging of peripheral nerve in patients with chronic inflammatory demyelinating polyradiculoneuropathy: a feasibility study
    Takako Kakuda
    Hiroshi Fukuda
    Keizo Tanitame
    Miyuki Takasu
    Shuji Date
    Kazuhide Ochi
    Tomohiko Ohshita
    Tatsuo Kohriyama
    Katsuhide Ito
    Masayasu Matsumoto
    Kazuo Awai
    Neuroradiology, 2011, 53 : 955 - 960
  • [49] Ultrasound imaging of quadriceps muscle in patients with knee osteoarthritis: The test-retest and inter-rater reliability and concurrent validity of echo intensity measurement
    Karapinar, Merve
    Ayyildiz, Veysel Atilla
    Unal, Meric
    Firat, Tuzun
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2021, 56
  • [50] Test-Retest Reliability of Diffusion Measures Extracted Along White Matter Language Fiber Bundles Using HARDI-Based Tractography
    Boukadi, Mariem
    Marcotte, Karine
    Bedetti, Christophe
    Houde, Jean-Christophe
    Desautels, Alex
    Deslauriers-Gauthier, Samuel
    Chapleau, Marianne
    Bore, Arnaud
    Descoteaux, Maxime
    Brambati, Simona M.
    FRONTIERS IN NEUROSCIENCE, 2019, 12