Peripheral Nerve Diffusion Tensor Imaging Interreader and Test-retest Reliability as Quantified by the Standard Error of Measurement

被引:8
|
作者
Preisner, Fabian [1 ]
Baeumer, Philipp [1 ,2 ]
Wehrstein, Michaela [3 ]
Friedmann-Bette, Birgit [3 ]
Hackbusch, Matthes [4 ]
Heiland, Sabine [1 ]
Bendszus, Martin [1 ]
Kronlage, Moritz [1 ]
机构
[1] Heidelberg Univ Hosp, Dept Neuroradiol, Neuenheimer Feld 400, D-69120 Heidelberg, Germany
[2] Ctr Radiol Dialog, Vinzenz von Paul Str 8, D-84503 Altotting, Germany
[3] Heidelberg Univ Hosp, Dept Sports Med Internal Med 7, Med Clin, Neuenheimer Feld 410, D-69120 Heidelberg, Germany
[4] Heidelberg Univ, Inst Med Biometry & Informat, Neuenheimer Feld 130-3, D-69120 Heidelberg, Germany
关键词
Diffusion tensor imaging; Magnetic resonance imaging; Peripheral nervous system; Reference values; Reproducibility of results; INTRACLASS CORRELATION-COEFFICIENTS; MAGNETIC-RESONANCE NEUROGRAPHY; MEDIAN NERVE; FIBER TRACTOGRAPHY; MR NEUROGRAPHY; FRACTIONAL ANISOTROPY; DIAGNOSTIC-ACCURACY; TUNNEL; NEUROPATHY; AGREEMENT;
D O I
10.1007/s00062-019-00859-0
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose Diffusion tensor imaging (DTI) is increasingly being used in magnetic resonance neurography (MRN). The purpose of this study was to determine the interreader and test-retest reliability of peripheral nerve DTI in MRN with focus on the sciatic nerve. Methods In this prospective study 27 healthy volunteers each underwent 3 scans of a short DTI protocol on separate days consisting of a T2-weighted turbo spin-echo and single-shot DTI sequence of the sciatic nerve of the dominant leg. The DTI parameters fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) were obtained after manual nerve segmentation by two independent readers. Intraclass correlation coefficients (ICC), standard error of measurement (SEM), and Bland-Altman plots were calculated as measures for both interreader and test-retest agreement for all readout parameters. Results The mean +/- standard deviation was 0.507 +/- 0.05 for FA, 1308.5 +/- 162.4x 10(-6)mm(2)/s for MD, 905.6 +/- 145.4x10(-6)mm(2)/s for RD and 2114.1 +/- 219.2x 10(-6)mm(2)/s for AD. The SEM for FA was 0.02 for interreader and test-retest agreement, the SEM for MD, RD, and AD ranged between 46.2x 10(-6)mm(2)/s (RD) and 70.1x 10(-6)mm(2)/s (AD) for interreader reliability and between 45.9x 10(-6)mm(2)/s (RD) and 70.1x 10(-6)mm(2)/s (AD) for test-retest reliability. The ICC for interreader reliability of DTI parameters ranged between 0.81 and 0.92 and ICC for test-retest reliability between 0.76 and 0.91. Conclusion Peripheral nerve DTI of the sciatic nerve is reliable and reproducible. The measures presented here may serve as first orientation values of measurement accuracy when interpreting parameters of sciatic nerve DTI.
引用
收藏
页码:679 / 689
页数:11
相关论文
共 50 条
  • [21] Test-Retest Reliability of Diffusion Measures in Cerebral White Matter: A Multiband Diffusion MRI Study
    Duan, Fei
    Zhao, Tengda
    He, Yong
    Shu, Ni
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (04) : 1106 - 1116
  • [22] Peripheral nerve diffusion tensor imaging is reliable and reproducible
    Simon, Neil G.
    Lagopoulos, Jim
    Gallagher, Thomas
    Kliot, Michel
    Kiernan, Matthew C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (04) : 962 - 969
  • [23] Test-retest reliability and measurement error of the Danish WHO-5 Well-being Index in outpatients with epilepsy
    Liv Marit Valen Schougaard
    Annette de Thurah
    Per Bech
    Niels Henrik Hjollund
    David Høyrup Christiansen
    Health and Quality of Life Outcomes, 16
  • [24] A comparison of test-retest reliability and random measurement error of the Barthel Index and modified Barthel Index in patients with chronic stroke
    Yang, Chun Ming
    Wang, Yi-Ching
    Lee, Chia-Hua
    Chen, Mei-Hsiang
    Hsieh, Ching-Lin
    DISABILITY AND REHABILITATION, 2022, 44 (10) : 2099 - 2103
  • [25] Peripheral nerve diffusion tensor imaging (DTI): normal values and demographic determinants in a cohort of 60 healthy individuals
    Moritz Kronlage
    Véronique Schwehr
    Daniel Schwarz
    Tim Godel
    Lorenz Uhlmann
    Sabine Heiland
    Martin Bendszus
    Philipp Bäumer
    European Radiology, 2018, 28 : 1801 - 1808
  • [26] The Test-Retest Reproducibility, Standard Error Measurement, and Smallest Real Difference of Dynamic Balance Tests in Chronic Stroke Survivors
    Lee, Kyeongbong
    Lee, GyuChang
    APPLIED SCIENCES-BASEL, 2023, 13 (11):
  • [27] Test-retest reliability and measurement error of the Danish WHO-5 Well-being Index in outpatients with epilepsy
    Schougaard, Liv Marit Valen
    de Thurah, Annette
    Bech, Per
    Hjollund, Niels Henrik
    Christiansen, David Hoyrup
    HEALTH AND QUALITY OF LIFE OUTCOMES, 2018, 16
  • [28] Diffusion tensor imaging within the healthy cervical spinal cord: Within-participants reliability and measurement error
    Al-shaari, Hussein
    Fulford, Jon
    Heales, C. J.
    MAGNETIC RESONANCE IMAGING, 2024, 109 : 56 - 66
  • [29] Diffusion tensor imaging of peripheral nerve in patients with chronic inflammatory demyelinating polyradiculoneuropathy: a feasibility study
    Kakuda, Takako
    Fukuda, Hiroshi
    Tanitame, Keizo
    Takasu, Miyuki
    Date, Shuji
    Ochi, Kazuhide
    Ohshita, Tomohiko
    Kohriyama, Tatsuo
    Ito, Katsuhide
    Matsumoto, Masayasu
    Awai, Kazuo
    NEURORADIOLOGY, 2011, 53 (12) : 955 - 960
  • [30] Peripheral Nerve Diffusion Tensor Imaging: Assessment of Axon and Myelin Sheath Integrity
    Heckel, A.
    Weiler, M.
    Xia, A.
    Ruetters, M.
    Pham, M.
    Bendszus, M.
    Heiland, S.
    Baeumer, P.
    PLOS ONE, 2015, 10 (06):