Novel design and operational control of integrated ultrafiltration - Reverse osmosis system with RO concentrate backwash

被引:33
作者
Gao, Larry X. [1 ]
Rahardianto, Anditya [1 ]
Gu, Han [1 ]
Christofides, Panagiotis D. [1 ]
Cohen, Yoram [1 ]
机构
[1] Univ Calif Los Angeles, Dept Chem & Biomol Engn, Water Technol Res Ctr, Los Angeles, CA 90095 USA
基金
美国国家科学基金会;
关键词
Field study; Reverse osmosis desalination; Seawater desalination; Ultrafiltration; Process control; Pulse backwash; RO concentrate backwash; UF-RO integration; Process intensification; DESALINATION PLANT; UF PRETREATMENT; SEAWATER; MEMBRANE; PERFORMANCE; COST;
D O I
10.1016/j.desal.2015.12.022
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A novel design for a reverse osmosis (RO) desalination system directly integrated with an ultrafiltration (UF) pretreatment unit was developed. The integration involves direct RO feed from the UF filtrate and UF backwash using the RO concentrate. This alignment reduces overall plant footprint, while the use of RO concentrate for UF backwash allows 100% UF recovery and implementation of flexible backwash strategies. The present system design utilizes a control scheme, whereby RO productivity can be prescribed independently of the UF system which self-adjusts to provide the RO system with its required feed flow rate at the specified RO pump inlet pressure. UF backwash, achieved via direct RO concentrate flow from the RO system provided a continuous flow for sequential UF backwash which was additionally integrated with pulse backwash using a hydraulic accumulator. Seawater desalination field studies with a UF-R0 pilot system of 12,000 gal/day permeate production capacity successfully demonstrated the advantage of RO concentrate UF backwash that was triggered based on a membrane resistance threshold. The above self-adaptive UF backwash strategy significantly extended the projected UF operation period (by a factor of nine) to the threshold of required chemical cleaning. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 44 条
[1]   Potable water production from seawater by the reverse osmosis technique in Libya [J].
Aboabboud, Mohamed ;
Elmasallati, Salaheddin .
DESALINATION, 2007, 203 (1-3) :119-133
[2]   Removal of divalent cations reduces fouling of ultrafiltration membranes [J].
Abrahamse, A. J. ;
Lipreau, C. ;
Li, S. ;
Heijman, S. G. J. .
JOURNAL OF MEMBRANE SCIENCE, 2008, 323 (01) :153-158
[3]   Process control in water desalination industry: an overview [J].
Alatiqi, I ;
Ettouney, H ;
El-Dessouky, H .
DESALINATION, 1999, 126 (1-3) :15-32
[4]  
[Anonymous], 2015, ADV MEMBRANE TECHNOL
[5]  
Averink CWA, 2000, DESALINATION, V132, P167
[6]   Chemical cleaning of a tubular ceramic microfiltration membrane fouled with a whey protein concentrate suspension-Characterization of hydraulic and chemical cleanliness [J].
Blanpain-Avet, P. ;
Migdal, J. F. ;
Benezech, T. .
JOURNAL OF MEMBRANE SCIENCE, 2009, 337 (1-2) :153-174
[7]   Comparison of MF/UF pretreatment with conventional filtration prior to RO membranes for surface seawater desalination [J].
Brehant, A ;
Bonnelye, V ;
Perez, M .
DESALINATION, 2002, 144 (1-3) :353-360
[8]   Seawater RO plant operation and maintenance experience: Addur desalination plant operation assessment [J].
Burashid, K ;
Hussain, AR .
DESALINATION, 2004, 165 (1-3) :11-22
[9]  
Chang A.C., 2013, Salinity and Drainage in San Joaquin Valley
[10]  
CHAPPLE P, 2014, PRINCIPLES HYDRAULIC