Percutaneous treatment of liver tumors with an adapted probe for cooled-tip, impedance-controlled radio-frequency ablation under open-magnet MR guidance: initial results

被引:41
作者
Kelekis, AD [1 ]
Terraz, S [1 ]
Roggan, A [1 ]
Terrier, FO [1 ]
Majno, P [1 ]
Mentha, G [1 ]
Roth, A [1 ]
Becker, CD [1 ]
机构
[1] Univ Hosp Geneva, Dept Diagnost & Intervent Radiol, CH-1211 Geneva, Switzerland
关键词
secondary liver neoplasms; radio-frequency ablation; magnetic resonance imaging;
D O I
10.1007/s00330-003-1847-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Percutaneous radio-frequency (RF) ablation of liver tumors is usually performed under guidance of real-time US, but some tumor nodules in some patients cannot be adequately visualized with this technique. We report our preliminary results with an MR-compatible, internally perfused 17-G RF probe adapted to a standard RF generator for impedance-controlled RF ablation under MR guidance. Following initial testing of the probe for MR compatibility, artifacts and macroscopic effects on an ex vivo pig liver, four patients with eight neoplastic liver nodules (five metastatic and three primary), which could not be properly targeted by US, were treated with the cooled-tip technique under MRI guidance in art open 0.23-T magnet. Metallic artifacts produced by the probe were useful for accurate placement and did not interfere with MRI monitoring at the end of the procedure. Based on imaging findings, the immediate result of RF was considered adequate in all instances. Local recurrence occurred in one instance after 6 months, requiring repeat treatment. No adverse effects were noted. Initial experience suggests that the probe we used allows to perform impedance-controlled cooled-tip RF ablation of liver tumors under open-magnet MR guidance.
引用
收藏
页码:1100 / 1105
页数:6
相关论文
共 11 条
[1]   MnDPDP-enhanced MRI vs dual-phase spiral CT in the detection of hepatocellular carcinoma in cirrhosis [J].
Bartolozzi, C ;
Donati, F ;
Cioni, D ;
Crocetti, L ;
Lencioni, R .
EUROPEAN RADIOLOGY, 2000, 10 (11) :1697-1702
[2]   Liver lesions: Manganese-enhanced MR and dual-phase helical CT for preoperative detection and characterization - Comparison with receiver operating characteristic analysis [J].
Braga, HJV ;
Choti, MA ;
Lee, VS ;
Paulson, EK ;
Siegelman, ES ;
Bluemke, DA .
RADIOLOGY, 2002, 223 (02) :525-531
[3]   Survival after percutaneous, image-guided, thermal ablation of hepatic metastases from colorectal cancer [J].
Gillams, AR ;
Lees, WR .
DISEASES OF THE COLON & RECTUM, 2000, 43 (05) :656-661
[4]  
Goldberg SN, 2001, HEPATO-GASTROENTEROL, V48, P359
[5]   MR-guided radiofrequency ablation of hepatic neoplasms [J].
Huppert, PE ;
Trübenbach, J ;
Schick, F ;
Pereira, P ;
König, C ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (08) :692-700
[6]   Percutaneous radiofrequency thermal ablation of liver malignancies: techniques, indications, imaging findings, and clinical results [J].
Lencioni, R ;
Cioni, D ;
Bartolozzi, C .
ABDOMINAL IMAGING, 2001, 26 (04) :345-360
[7]   Interactive MRI-guided radiofrequency interstitial thermal ablation of abdominal tumors: Clinical trial for evaluation of safety and feasibility [J].
Lewin, JS ;
Connell, CF ;
Duerk, JL ;
Chung, YC ;
Clampitt, ME ;
Spisak, J ;
Gazelle, GS ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :40-47
[8]   Treatment of hepatocellular carcinoma by interventional methods [J].
Livraghi, T .
EUROPEAN RADIOLOGY, 2001, 11 (11) :2207-2219
[9]   Characterization of liver lesions with mangafodipir trisodium-enhanced MR imaging:: Multicenter study comparing MR and dual-phase spiral CT [J].
Oudkerk, M ;
Torres, CG ;
Song, B ;
König, M ;
Grimm, J ;
Fernandez-Cuadrado, J ;
de Beeck, BO ;
Marquardt, M ;
van Dijk, P ;
de Groot, JC .
RADIOLOGY, 2002, 223 (02) :517-524
[10]  
SCHLUP S, 2001, SWISS MED FORUM S, V3, P27