Spectral entropy and bispectral index as measures of the electroencephalographic effects of sevoflurane

被引:11
|
作者
Ellerkmann, RK
Liermann, VM
Alves, TM
Wenningmann, I
Kreuer, S
Wilhelm, W
Roepcke, H
Hoeft, A
Bruhn, J
机构
[1] Univ Bonn, Dept Anesthesiol & Intens Care Med, D-5300 Bonn, Germany
[2] Univ Saarland, Dept Anesthesiol & Intens Care Med, D-6650 Homburg, Germany
[3] Hosp Luenen, Dept Anesthesiol & Intens Care Med, Luenen, Germany
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Recently, entropy algorithms have been proposed as electroencephalographic measures of anesthetic drug effects. Datex-Ohmeda (Helsinki, Finland) introduced the Entropy Module, a new electroencephalographic monitor designed for measuring depth of anesthesia. The monitor calculates a state entropy (SE) computed over the frequency range of 0.8-32 Hz and a response entropy (RE) computed over the frequency range of 0.8-47 Hz. The authors investigated the dose-response relation of SE and RE during sevoflurane anesthesia in comparison with the Bispectral Index (BIS). Methods: Sixteen patients were studied without surgical stimulus. Anesthesia was induced by sevoflurane inhalation with a tight-fitting facemask. Sevoflurane concentrations were increased and subsequently decreased and increased two to four times until the measurement was stopped and patients were intubated for surgery. The performances of SE, RE, and BIS to predict the estimated sevoflurane effect site concentration, obtained by simultaneous pharmacokinetic and pharmacodynamic modeling, were compared by calculating the correlation coefficients and the prediction probability. Results: State entropy, RE, and BIS values decreased continuously over the observed concentration range of sevoflurane. Correlation coefficients were slightly but not significantly better for entropy parameters (0.87 +/- 0.09 and 0.86 +/- 0.10 for SE and RE, respectively) than for BIS (0.85 0.12). Calculating the prediction probability confirmed these results with a prediction probability of 0.84 +/- 0.05 and 0.82 +/- 0.06 for SE and RE, respectively, and 0.80 +/- 0.06 for BIS. Conclusion: State entropy and RE seem to be useful electroencephalographic measures of sevoflurane drug effect.
引用
收藏
页码:1275 / 1282
页数:8
相关论文
共 50 条
  • [1] Spectral entropy and bispectral index as measures of the electroencephalographic effects of propofol
    Ellerkmann, RK
    Soehle, M
    Alves, TM
    Liermann, VM
    Wenningmann, I
    Roepcke, H
    Kreuer, S
    Hoeft, A
    Bruhn, J
    ANESTHESIA AND ANALGESIA, 2006, 102 (05): : 1456 - 1462
  • [2] Spectral Entropy and bispectral index as measures of the EEG effects of sevoflurane
    Ellerkmann, R. K.
    Liermann, M.
    Alves, T.
    Roepke, H.
    Wenningmann, I.
    Hoeft, A.
    Bruhn, J.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 34 - 34
  • [3] Comparative effects of ketamine on Bispectral Index and spectral entropy of the electroencephalogram under sevoflurane anaesthesia
    Hans, P
    Dewandre, PY
    Brichant, JF
    Bonhomme, V
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (03) : 336 - 340
  • [4] Does monitoring bispectral index of spectral entropy reduce sevoflurane use?
    Aime, Isabelle
    Verroust, Nicolas
    Masson-Lefoll, Cecile
    Taylor, Guillaume
    Laloe, Pierre-Antoine
    Liu, Ngai
    Fischler, Marc
    ANESTHESIA AND ANALGESIA, 2006, 103 (06): : 1469 - 1477
  • [5] Comparative effects of a bolus of ketamine on Bispectral Index and Spectral Entropy of the EEG during sevoflurane anaesthesia
    Hans, P.
    Dewandre, P. Y.
    Detheux, G.
    Llabres, V.
    Brichant, J. F.
    Bonhomme, V.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 : 32 - 32
  • [6] Comparison between Bispectral Index and Patient State Index as Measnres of the Electroencephalographic Effects of Sevoflurane
    Soehle, Martin
    Ellerkmann, Richard K.
    Grube, Matthias
    Kuech, Matthias
    Wirz, Stefan
    Hoeft, Andreas
    Bruhn, Joergen
    ANESTHESIOLOGY, 2008, 109 (05) : 799 - 805
  • [7] Comparison between cerebral state index and bispectral index as measures of electroencephalographic effects of sevoflurane using combined sigmoidal Emax model
    Han, Dong Woo
    Linares-Perdomo, Olinto-Jose
    Lee, Jong Seok
    Kim, Jun Ho
    Kern, Steven E.
    ACTA PHARMACOLOGICA SINICA, 2011, 32 (10) : 1208 - 1214
  • [8] Comparison between cerebral state index and bispectral index as measures of electroencephalographic effects of sevoflurane using combined sigmoidal Emax model
    Dong Woo Han
    Olinto-Jose Linares-Perdomo
    Jong Seok Lee
    Jun Ho Kim
    Steven E Kern
    Acta Pharmacologica Sinica, 2011, 32 : 1208 - 1214
  • [9] Transcranial Doppler ultrasound, bispectral index, and electroencephalographic monitoring of entropy during sevoflurane anesthesia in children
    Abad Gurumeta, A.
    Calvo Vecino, J. M.
    Abad Motos, A.
    Oliden Gutierrez, L.
    Garcia Alvarez, R.
    Nieto Moreno, A.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2010, 57 (10): : 630 - 638
  • [10] Patient state index vs bispectral index as measures of the electroencephalographic effects of propofol
    Soehle, M.
    Kuech, M.
    Grube, M.
    Wirz, S.
    Kreuer, S.
    Hoeft, A.
    Bruhn, J.
    Ellerkmann, R. K.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (02) : 172 - 178