Preliminary assays to elucidate the structure of oxytetracycline's degradation products in sediments -: Determination of natural tetracyclines by high-performance liquid chromatography-fast atom bombardment mass spectrometry

被引:48
作者
Delépée, R
Maume, D
Le Bizec, B
Pouliquen, H
机构
[1] Ecole Natl Vet, INRA, UMR, F-44307 Nantes 03, France
[2] Ecole Natl Vet, LDH, LNR, Lab Natl Reference Facteurs Croissance, F-44307 Nantes, France
来源
JOURNAL OF CHROMATOGRAPHY B | 2000年 / 748卷 / 02期
关键词
oxytetracycline; tetracycline; chlortetracycline; mass spectrometry; LC-MS; frit FAB; particle beam;
D O I
10.1016/S0378-4347(00)00355-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A very specific high-performance liquid chromatography-mass spectrometric method for the determination of natural tetracyclines was developed in order to characterise the degradation products of oxytetracycline in sediments. First, extraction used a clean up step with a Bond Elut Certify(R) LRC cartridge. A 3 mum Spherisorb(R) ODS1 column was then used with a methanol, acetonitrile and oxalic acid mobile phase gradient. Chromatographic resolution in these conditions was 3.31 between oxytetracycline and tetracycline. Two liquid chromatography-mass spectrometry methodologies based on a particle beam and a frit fast atom bombardment interface were developed. In the first approach, ionisation was performed in the negative chemical mode using methane as reacting gas. In the other case, glycerol-thioglycerol mixture was used as matrix to ensure good sensitivity. MS-MS experiment was performed to determinate oxytetracycline fragmentation pattern in the perspective of degradation product study. (C) 2000 Elsevier Science BN. All rights reserved.
引用
收藏
页码:369 / 381
页数:13
相关论文
共 29 条
[11]  
KENION GB, 1990, ACS SYM SER, V420, P101
[12]   CONFIRMATION OF OXYTETRACYCLINE, TETRACYCLINE AND CHLORTETRACYCLINE RESIDUES IN MILK BY PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KIJAK, PJ ;
LEADBETTER, MG ;
THOMAS, MH ;
THOMPSON, EA .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (12) :789-795
[13]  
MYLCREEST I, 1992, COMMUNICATION
[14]   Simultaneous determination of residual tetracyclines in foods by high-performance liquid chromatography with atmospheric pressure chemical ionization tandem mass spectrometry [J].
Nakazawa, H ;
Ino, S ;
Kato, K ;
Watanabe, T ;
Ito, Y ;
Oka, H .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 732 (01) :55-64
[15]  
NIESSEN WMA, 1992, LIQUID CHROMATOGRAPH, P203
[16]   IMPROVEMENT OF CHEMICAL-ANALYSIS OF ANTIBIOTICS .22. IDENTIFICATION OF RESIDUAL TETRACYCLINES IN HONEY BY FRIT FAB/LC/MS USING A VOLATILE MOBILE-PHASE [J].
OKA, H ;
IKAI, Y ;
HAYAKAWA, J ;
HARADA, K ;
ASUKABE, H ;
SUZUKI, M ;
HIMEI, R ;
HORIE, M ;
NAKAZAWA, H ;
MACNEIL, JD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (10) :2215-2219
[17]  
OKA H, 1994, J AOAC INT, V77, P891
[18]   Improvement of chemical analysis of antibiotics .23. Identification of residual tetracyclines in bovine tissues by electrospray high-performance liquid chromatography tandem mass spectrometry [J].
Oka, H ;
Ikai, Y ;
Ito, Y ;
Hayakawa, J ;
Harada, K ;
Suzuki, M ;
Odani, H ;
Maeda, K .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 693 (02) :337-344
[19]   IMPROVEMENT OF CHEMICAL-ANALYSIS OF ANTIBIOTICS .18. IDENTIFICATION OF RESIDUAL TETRACYCLINES IN BOVINE-TISSUES BY TLC FABMS WITH A SAMPLE CONDENSATION TECHNIQUE [J].
OKA, H ;
IKAI, Y ;
HAYAKAWA, J ;
MASUDA, K ;
HARADA, K ;
SUZUKI, M ;
MARTZ, V ;
MACNEIL, JD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (03) :410-415
[20]  
PASCO L, 1994, CNEVA ISPAIA, P117