Fabrication and quality factor control of a microelectromechanical system resonator with linear differential drive

被引:8
作者
Anthony, C. [1 ]
Turnbull, R. [2 ]
Wei, X. [1 ]
Ward, M. [1 ]
Collins, S. [2 ]
机构
[1] Univ Birmingham, Sch Mech Engn, Birmingham, W Midlands, England
[2] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
基金
英国工程与自然科学研究理事会;
关键词
MEMS; MICROCANTILEVERS; TECHNOLOGIES; SENSORS; SILICON;
D O I
10.1049/iet-smt.2009.0081
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fabrication, characterisation and quality factor control of a microelectromechanical system resonator with differential drive and readout is reported. The differential drive results in a linear relationship between the AC drive voltage and the applied force. Furthermore, the static DC force and the undesirable force at the second harmonic frequency (introduced by other driving methods) are also reduced. Differential readout is employed in order to minimise undesirable common-mode signals in the detection electronics. The device has been fabricated in silicon on insulator (using the Integram high aspect ratio micromachining process at QinetiQ) and fully characterised. The ability to track the resonant frequency with. ne resolution is related to the quality factor of the resonant system. Commonly used detection techniques such as slope detection and phase detection both require a high quality factor, however, resistance to motion caused by air damping results in a low quality factor - degrading the performance of the sensor. The low-pressure quality factor is measured as being >5500 and reduces to similar to 10 at atmospheric pressure. The linear relationship between AC drive voltage and resultant force is exploited in conjunction with an electronic readout architecture yielding the device velocity to implement a force feedback technique - increasing the quality factor of the resonator.
引用
收藏
页码:206 / 213
页数:8
相关论文
共 27 条
[1]   Phase detection of the two-port FPW sensor for biosensing [J].
Chang, Wen-Yang ;
Sung, Po-Hsun ;
Chu, Chun-Hsun ;
Shih, Ching-Jui ;
Lin, Yu-Cheng .
IEEE SENSORS JOURNAL, 2008, 8 (5-6) :501-507
[2]   ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS [J].
CHEN, GY ;
THUNDAT, T ;
WACHTER, EA ;
WARMACK, RJ .
JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) :3618-3622
[3]   AIR AND GAS DAMPING OF QUARTZ TUNING FORKS [J].
CHRISTEN, M .
SENSORS AND ACTUATORS, 1983, 4 (04) :555-564
[4]   Silicon on nothing MEMS electromechanical resonator [J].
Durand, Cedric ;
Casset, Fabrice ;
Ancey, Pascal ;
Judong, Fabienne ;
Talbot, Alexandre ;
Quenouillere, Remi ;
Renaud, Denis ;
Borel, Stephan ;
Florin, Brigitte ;
Buchaillot, Lionel .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2008, 14 (07) :1027-1033
[5]   Engineering MEMS resonators with low thermoelastic damping [J].
Duwel, Amy ;
Candler, Rob N. ;
Kenny, Thomas W. ;
Varghese, Mathew .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (06) :1437-1445
[6]  
HSU WT, 2006, IEEE FREQ CONTR S MI
[7]  
KIM B, 2006, 19 IEEE INT WORKSH M, P590
[8]   High-frequency metallic nanomechanical resonators [J].
Li, T. F. ;
Pashkin, Yu. A. ;
Astafiev, O. ;
Nakamura, Y. ;
Tsai, J. S. ;
Im, H. .
APPLIED PHYSICS LETTERS, 2008, 92 (04)
[9]   ATOMIC FORCE MICROSCOPE FORCE MAPPING AND PROFILING ON A SUB 100-A SCALE [J].
MARTIN, Y ;
WILLIAMS, CC ;
WICKRAMASINGHE, HK .
JOURNAL OF APPLIED PHYSICS, 1987, 61 (10) :4723-4729
[10]   High aspect ratio micromachining (HARM) technologies for microinertial devices [J].
McNie, M ;
King, D ;
Vizard, C ;
Holmes, A ;
Lee, KW .
MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2000, 6 (05) :184-188