Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences

被引:4
|
作者
Inoue, Katsuhiro [1 ]
Maeda, Masayuki [2 ]
Umino, Maki [3 ]
Takase, Shinichi [1 ]
Yamahata, Tsunehiro [1 ]
Sakuma, Hajime [3 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[2] Mie Univ, Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Mie Univ, Sch Med, Depatment Radiol, Tsu, Mie 5148507, Japan
基金
日本学术振兴会;
关键词
Carotid plaque; Magnetic resonance imaging; Black blood; 3D imaging; INTRAPLAQUE HEMORRHAGE; RISK; PROGRESSION; DISEASE; MRI;
D O I
10.1016/j.ejrad.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field -echo (TFE) black blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1 -TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1 -TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1-TFEBB MRI than on 3D T1 -TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1 -TSEBB MRI. Conclusions: 3D Tl-TSEBB MRI was superior to 3D Tl-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1 -TSEBB MRI. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1035 / 1039
页数:5
相关论文
共 50 条
  • [41] MR imaging of the knee: Improvement of signal and contrast efficiency of T1-weighted turbo spin echo sequences by applying a driven equilibrium (DRIVE) pulse
    Radlbauer, Rudolf
    Lomoschitz, Friedrich
    Salomonowitz, Erich
    Eberhardt, Knut E.
    Stadlbauer, Andreas
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : E82 - E87
  • [42] Locally advanced rectal cancer: 3D diffusion-prepared stimulated-echo turbo spin-echo versus 2D diffusion-weighted echo-planar imaging
    Qinwei Zhang
    Petra J. van Houdt
    Doenja M. J. Lambregts
    Baukelien van Triest
    Marnix P. M. Kop
    Bram F. Coolen
    Gustav J. Strijkers
    Uulke A. van der Heide
    Aart J. Nederveen
    European Radiology Experimental, 4
  • [43] Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences
    Altahawi, Faysal F.
    Blount, Kevin J.
    Morley, Nicholas P.
    Raithel, Esther
    Omar, Imran M.
    SKELETAL RADIOLOGY, 2017, 46 (01) : 7 - 15
  • [44] Carotid Arterial Wall MRI at 3T Using 3D Variable-Flip-Angle Turbo Spin-Echo (TSE) with Flow-Sensitive Dephasing (FSD)
    Fan, Zhaoyang
    Zhang, Zhuoli
    Chung, Yiu-Cho
    Weale, Peter
    Zuehlsdorff, Sven
    Carr, James
    Li, Debiao
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 645 - 654
  • [45] 3D Fast Spin-Echo T1 Black-Blood Imaging for the Preoperative Detection of Venous Sinus Invasion by MeningiomaComparison with Contrast-Enhanced MRV
    Dongdong Wang
    Yiping Lu
    Bo Yin
    Mingyu Chen
    Daoying Geng
    Li Liu
    Jianbo Wen
    Ping Zhong
    Yuan Li
    Clinical Neuroradiology, 2019, 29 : 65 - 73
  • [46] T1-weighted MR imaging of glioma at 3T: a comparative study of 3D MPRAGE vs. conventional 2D spin-echo imaging
    Dodo, Toshiki
    Okada, Tomohisa
    Yamamoto, Akira
    Kanagaki, Mitsunori
    Fushimi, Yasutaka
    Okada, Tsutomu
    Sakata, Akihiko
    Arakawa, Yoshiki
    Miyamoto, Susumu
    Togashi, Kaori
    CLINICAL IMAGING, 2016, 40 (06) : 1257 - 1261
  • [47] Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T
    Vymazal, Josef
    Ryznarova, Zuzana
    Rulseh, Aaron M.
    INSIGHTS INTO IMAGING, 2024, 15 (01)
  • [48] Preoperative detection of malignant liver tumors: Comparison of 3D-T2-weighted sequences with T2-weighted turbo spin-echo and single shot T2 at 1.5 T
    Barat, Maxime
    Soyer, Philippe
    Dautry, Raphael
    Pocard, Marc
    Lo-Dico, Rea
    Najah, Haythem
    Eveno, Clarisse
    Cassinotto, Christophe
    Dohan, Anthony
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 : 7 - 13
  • [49] Comparison between postcontrast thin-slice T1-weighted 2D spin echo and 3D T1-weighted SPACE sequences in the detection of brain metastases at 1.5 and 3 T
    Josef Vymazal
    Zuzana Ryznarova
    Aaron M. Rulseh
    Insights into Imaging, 15
  • [50] Visual discrimination among patients with depression and schizophrenia and healthy individuals using semiquantitative color-coded fast spin-echo T1-weighted magnetic resonance imaging
    Sasaki, Makoto
    Shibata, Eri
    Ohtsuka, Kotaro
    Endoh, Jin
    Kudo, Kohsuke
    Narumi, Shinsuke
    Sakai, Akio
    NEURORADIOLOGY, 2010, 52 (02) : 83 - 89