Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences

被引:4
作者
Inoue, Katsuhiro [1 ]
Maeda, Masayuki [2 ]
Umino, Maki [3 ]
Takase, Shinichi [1 ]
Yamahata, Tsunehiro [1 ]
Sakuma, Hajime [3 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[2] Mie Univ, Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Mie Univ, Sch Med, Depatment Radiol, Tsu, Mie 5148507, Japan
基金
日本学术振兴会;
关键词
Carotid plaque; Magnetic resonance imaging; Black blood; 3D imaging; INTRAPLAQUE HEMORRHAGE; RISK; PROGRESSION; DISEASE; MRI;
D O I
10.1016/j.ejrad.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field -echo (TFE) black blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1 -TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1 -TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1-TFEBB MRI than on 3D T1 -TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1 -TSEBB MRI. Conclusions: 3D Tl-TSEBB MRI was superior to 3D Tl-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1 -TSEBB MRI. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1035 / 1039
页数:5
相关论文
共 25 条
[21]   Embolic complications after carotid artery stenting or carotid endarterectomy are associated with tissue characteristics of carotid plaques evaluated by magnetic resonance imaging [J].
Yamada, Kiyofumi ;
Yoshimura, Shinichi ;
Kawasaki, Masanori ;
Enomoto, Yukiko ;
Asano, Takahiko ;
Hara, Akira ;
Minatoguchi, Shinya ;
Iwama, Toru .
ATHEROSCLEROSIS, 2011, 215 (02) :399-404
[22]  
Yamada N, 2007, AM J NEURORADIOL, V28, P287
[23]   Evaluation of carotid artery atherosclerotic plaque distribution by using long-axis high-resolution black-blood magnetic resonance imaging Clinical article [J].
Yoshida, Kazumichi ;
Endo, Hideki ;
Sadamasa, Nobutake ;
Narumi, Osamu ;
Chin, Masaki ;
Inoue, Katsumi ;
Mitsudo, Kazuaki ;
Yamagata, Sen .
JOURNAL OF NEUROSURGERY, 2008, 109 (06) :1042-1048
[24]   In vivo accuracy of multispectral magnetic resonance imaging for identifying lipid-rich necrotic cores and intraplaque hemorrhage in advanced human carotid plaques [J].
Yuan, C ;
Mitsumori, LM ;
Ferguson, MS ;
Polissar, NL ;
Echelard, D ;
Ortiz, G ;
Small, R ;
Davies, JW ;
Kerwin, WS ;
Hatsukami, TS .
CIRCULATION, 2001, 104 (17) :2051-2056
[25]   Assessment of Carotid Artery Atherosclerotic Disease by Using Three-dimensional Fast Black-Blood MR Imaging: Comparison with DSA [J].
Zhao, Huilin ;
Wang, Jinnan ;
Liu, Xiaosheng ;
Zhao, Xihai ;
Hippe, Daniel S. ;
Cao, Ye ;
Wan, Jieqing ;
Yuan, Chun ;
Xu, Jianrong .
RADIOLOGY, 2015, 274 (02) :508-516