Cervical carotid plaque evaluation using 3D T1-weighted black-blood magnetic resonance imaging: Comparison of turbo field-echo and turbo spin-echo sequences

被引:4
|
作者
Inoue, Katsuhiro [1 ]
Maeda, Masayuki [2 ]
Umino, Maki [3 ]
Takase, Shinichi [1 ]
Yamahata, Tsunehiro [1 ]
Sakuma, Hajime [3 ]
机构
[1] Mie Univ Hosp, Dept Radiol, Tsu, Mie, Japan
[2] Mie Univ, Sch Med, Dept Adv Diagnost Imaging, 2-174 Edobashi, Tsu, Mie 5148507, Japan
[3] Mie Univ, Sch Med, Depatment Radiol, Tsu, Mie 5148507, Japan
基金
日本学术振兴会;
关键词
Carotid plaque; Magnetic resonance imaging; Black blood; 3D imaging; INTRAPLAQUE HEMORRHAGE; RISK; PROGRESSION; DISEASE; MRI;
D O I
10.1016/j.ejrad.2016.03.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the capability of three-dimensional (3D) T1-weighted turbo field -echo (TFE) black blood (BB) magnetic resonance imaging (MRI) and turbo-spin echo (TSE) BB MRI for discerning carotid plaques and the difference of signal intensities of the plaques from that of adjacent muscle in patients with cervical carotid stenosis. Methods: Cervical carotid stenosis was evaluated by 3.0-T MR in 43 patients (38 men and 5 women; age, 36-83 years; mean age, 70 years) during 8 months. The carotid BB MRI comprised 3D T1-weighted TSE BB (T1-TSEBB) and 3D T1-weighted TFE BB (T1-TFEBB) sequences. The delineation of the carotid plaque border was evaluated in comparison with digital subtraction angiography (DSA). The border between the plaque and vessel lumen was rated visually (4-point analysis) and quantitatively (contrast-to-noise ratio). The signal-intensity ratio (SIR) of the plaque to the adjacent muscle was also measured. Data of 3D T1 -TSEBB and 3D T1-TFEBB were compared statistically using the Wilcoxon signed-rank test. Results: Visual and quantitative analyses revealed that the border between the plaque and vessel lumen was better delineated on 3D T1 -TSEBB MRI than on 3D T1-TFEBB MRI (p < 0.01, respectively). SIR of the plaque-to-adjacent muscle was higher on 3D T1-TFEBB MRI than on 3D T1 -TSEBB MRI (p < 0.05). High signal plaques with a SIR of >1.5 were underestimated on 3D T1 -TSEBB MRI. Conclusions: 3D Tl-TSEBB MRI was superior to 3D Tl-TFEBB MRI for delineating carotid plaques; however, high signal plaques were underestimated on 3D T1 -TSEBB MRI. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1035 / 1039
页数:5
相关论文
共 50 条
  • [1] Characterization of carotid atherosclerosis with black-blood carotid plaque imaging using variable flip-angle 3D turbo spin-echo: Comparison with 2D turbo spin-echo sequences
    Takano, Koichi
    Yamashita, Shinnichi
    Takemoto, Koichiro
    Inoue, Tooru
    Sakata, Noriyuki
    Kuwabara, Yasuo
    Yoshimitsu, Kengo
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (03) : E304 - E309
  • [2] Semiautomated Segmentation and Volume Measurements of Cervical Carotid High-Signal Plaques Using 3D Turbo Spin-Echo T1-Weighted Black-Blood Vessel Wall Imaging: A Preliminary Study
    Inoue, Katsuhiro
    Nakayama, Ryohei
    Isoshima, Shiho
    Takase, Shinichi
    Yamahata, Tsunehiro
    Umino, Maki
    Maeda, Masayuki
    Sakuma, Hajime
    DIAGNOSTICS, 2022, 12 (04)
  • [3] T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques
    Narumi, Shinsuke
    Sasaki, Makoto
    Miyazawa, Haruna
    Natori, Tatsunori
    Ito, Kohei
    Ogasawara, Kuniaki
    Kobayashi, Masakazu
    Hitomi, Jiro
    Terayama, Yasuo
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (02) : 273 - 279
  • [4] Three-Dimensional Black-Blood T1-Weighted Turbo Spin-Echo Techniques for the Diagnosis of Deep Vein Thrombosis in Comparison With Contrast-Enhanced Magnetic Resonance Imaging A Pilot Study
    Treitl, Karla Maria
    Treitl, Marcus
    Kooijman-Kurfuerst, Hendrik
    Kammer, Nora N.
    Coppenrath, Eva
    Suderland, Elena
    Czihal, Michael
    Hoffmann, Ulrich
    Reiser, Maximilian F.
    Saam, Tobias
    INVESTIGATIVE RADIOLOGY, 2015, 50 (06) : 401 - 408
  • [5] Utility of 3D T1-weighted turbo spin echo black blood sequence for the diagnosis of cerebral venous thrombosis
    Ahmed, Sabha
    Arora, Ankit
    Kulanthaivelu, Karthik
    Saini, Jitender
    Menon, Deepak
    Chakrabarti, Dhritiman
    EMERGENCY RADIOLOGY, 2023, 30 (04) : 443 - 451
  • [6] Application of T1-weighted BLADE sequence to abdominal magnetic resonance imaging of young children: a comparison with turbo spin echo sequence
    Choi, Kyu Sung
    Choi, Young Hun
    Cheon, Jung-Eun
    Kim, Woo Sun
    Kim, In One
    ACTA RADIOLOGICA, 2020, 61 (10) : 1406 - 1413
  • [7] Evaluation of the Canine Intervertebral Disc Structure in Turbo Spin Echo-T2 and Fast Field Echo-T1 Sequences in Magnetic Resonance Imaging
    Kunze, Katarina
    Stein, Veronika Maria
    Tipold, Andrea
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [8] Compressed SENSE accelerated 3D T1w black blood turbo spin echo versus 2D T1w turbo spin echo sequence in pituitary magnetic resonance imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    Wyss, Michael
    Schwenk, Arpad
    van Smoorenburg, Luuk
    Eichenberger, Barbara
    Najafi, Arash
    Binkert, Christoph
    Becker, Anton S.
    Sartoretti-Schefer, Sabine
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [9] Spiral 3-Dimensional T1-Weighted Turbo Field Echo: Increased Speed for Magnetization-Prepared Gradient Echo Brain Magnetic Resonance Imaging
    Sartoretti, Thomas
    Sartoretti, Elisabeth
    van Smoorenburg, Luuk
    Schwenk, Arpad
    Mannil, Manoj
    Graf, Nicole
    Binkert, Christoph A.
    Wyss, Michael
    Sartoretti-Schefer, Sabine
    INVESTIGATIVE RADIOLOGY, 2020, 55 (12) : 775 - 784
  • [10] Free-Breathing Radial 3D Fat-Suppressed T1-Weighted Gradient-Echo Sequence for Contrast-Enhanced Pediatric Spinal Imaging: Comparison With T1-Weighted Turbo Spin-Echo Sequence
    Cho, Hyun-Hae
    Choi, Young Hun
    Cheon, Jung-Eun
    Lee, So Mi
    Kim, Woo Sun
    Kim, In-One
    Paek, MunYoung
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 177 - 182