Carbon paste electrode modified with functionalized nanoporous silica gel as a new sensor for determination of silver ion

被引:109
作者
Javanbakht, Mehran [1 ]
Ganjali, Mohammad Reza
Norouzi, Parviz
Badiei, Alireza
Hasheminasab, Abed
Abdouss, Majid
机构
[1] Amirkabir Univ Technol, Dept Chem, Tehran, Iran
[2] Univ Tehran, Fac Chem, Ctr Excellence Electrochem, Tehran, Iran
[3] Univ Tehran Med Sci, Endocrine & Metab Res Ctr, Tehran, Iran
[4] Univ Tehran, Univ Coll Sci, Sch Chem, Tehran, Iran
关键词
potentiometric; electrode; nanoporous; silica gel; silver; carbon paste;
D O I
10.1002/elan.200603854
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new dipyridyl-functionalized silica gel (DPSG) was synthesized. The potentiometric response of silver ion was investigated at a carbon paste electrode chemically modified with functionalized nanoporous silica gel. The electrodes with a DPSG proportions of 10.1% (w/w), showed very stable potential. Calibration plots with Nernstian slopes for Ag+ were observed, 58.7 (+/- 0.9) mV decade(-1), over a wide linear range of concentration (5.0 x 10(-7) to 1.0 x 10(-1) M). ne electrode has a detection limit of 1.0 X 10(-7) M. The selectivity coefficients measured by the match potential method in acetate buffer, pH 5.5, were investigated. The electrode has fast response time, high performance, high sensitivity in wide cation activity ranges, and good long term stability (more than 6 months). The method was satisfactory and used to determine the concentration of silver ion in waste waters contaminated by this metal.
引用
收藏
页码:1307 / 1314
页数:8
相关论文
共 29 条
[1]   Carbon composition PVC based membrane in a highly selective and sensitive coated wire electrode for silver ion [J].
Abbaspour, A ;
Izadyar, A ;
Sharghi, H .
ANALYTICA CHIMICA ACTA, 2004, 525 (01) :91-96
[2]  
BUCHECKER COD, 1987, CHEM REV, V87, P795
[3]   Calixarene derivative as the neutral carrier in silver ion-selective electrode and liquid membrane transport [J].
Chen, LX ;
He, XW ;
Zhao, BT ;
Liu, Y .
ANALYTICA CHIMICA ACTA, 2000, 417 (01) :51-56
[4]   Solid contact potentiometric sensors for trace level measurements [J].
Chumbimuni-Torres, KY ;
Rubinova, N ;
Radu, A ;
Kubota, LT ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2006, 78 (04) :1318-1322
[5]   Silver(I)-selective PVC membrane potentiometric sensor based on a recently synthesized calix[4]arene [J].
Demirel, Ayca ;
Dogan, Alev ;
Akkus, Gulderen ;
Yilmaz, Mustafa ;
Kilic, Esma .
ELECTROANALYSIS, 2006, 18 (10) :1019-1027
[6]  
Environmental Protection Agency (EPA), 1980, 440580071 EPA
[7]  
Ganjali MR, 2002, ELECTROANAL, V14, P526, DOI 10.1002/1521-4109(200204)14:7/8<526::AID-ELAN526>3.0.CO
[8]  
2-O
[9]  
IUPAC, 1979, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[10]  
Javanbakht M, 1999, ELECTROANAL, V11, P81