Measureme of λ-i characteristics of asymmetric three-phase transformers and their applications

被引:38
作者
Fuchs, EF [1 ]
You, YM
机构
[1] Univ Colorado, Boulder, CO 80309 USA
[2] Tianjin Polytech Univ, Tianjin, Peoples R China
关键词
(lambda(o)-i(o)) characteristic for tank; nonlinear (lambda-i); characteristic for each limb; transformers with three limbs;
D O I
10.1109/TPWRD.2002.803702
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Modeling of three-phase transformers with three-limb cores is important, such units are very ubiquitous and are asymmetric due to the different lengths of the three limbs of the core. It is, therefore, important to devise a measuring procedure, where the (lambda-i) characteristics of the three limbs and the zero-sequence (lambda(0)-i(0)) characteristic due to the tank can be determined. A simulation program is developed so that currents at no-load and symmetric or asymmetric loads can be computed. Measured currents are compared with computed results for 2.3-kVA and 45-kVA units.