Bilateral Low-Dose Computed Tomography Assessment for Post-Operative Rotational Malalignment After Intramedullary Nailing for Tibial Shaft Fractures: Reliability of a Practical Imaging Technique

被引:21
作者
Bleeker, Nils Jan [1 ]
Cain, Megan [2 ]
Rego, Mariana [3 ]
Saarig, Aimane [1 ,4 ]
Chan, Andrew [3 ]
Sierevelt, Inger [5 ]
Doornberg, Job N. [6 ,7 ,8 ]
Jaarsma, Ruurd L. [2 ,9 ]
机构
[1] Flinders Univ S Australia, Flinders Med Ctr, Dept Orthopaed & Trauma Surg, Adelaide, SA, Australia
[2] Flinders Med Ctr, Dept Orthopaed & Trauma Surg, Adelaide, SA, Australia
[3] Flinders Univ S Australia, Flinders Med Ctr, Adelaide, SA, Australia
[4] Univ Amsterdam, Acad Med Ctr Amsterdam, Amsterdam, Netherlands
[5] Slotervaart Hosp, Amsterdam, Netherlands
[6] Acad Med Ctr Amsterdam, Dept Orthopaed Surg, Amsterdam, Netherlands
[7] Flinders Med Ctr, Adelaide, SA, Australia
[8] Flinders Univ S Australia, Adelaide, SA, Australia
[9] Flinders Univ S Australia, Orthopaed & Trauma Surg, Adelaide, SA, Australia
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2018年 / 49卷 / 10期
关键词
Tibial shaft fractures; Intramedullary nailing; Rotational malalignment; Bilateral low-dose CT assessments and reliability measurement technique; TORSION; MALROTATION; FIXATION; ALIGNMENT; OUTCOMES; TRIAL; FEMUR;
D O I
10.1016/j.injury.2018.07.031
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The purpose of this study is to evaluate the intra- and inter-observer reliability of low-dose protocolled bilateral postoperative Computed Tomography (CT)-assessment of rotational malalignment after intramedullary nailing (IMN) of tibial shaft fractures. Materials and methods: 156 patients were prospectively included with tibial shaft fractures that were treated with IMN in a Level-I Trauma Centre. All patients underwent post-operative bilateral low-dose CT-assessment (effective dose of 0.03784 - 0.05768 mGy) as per hospital protocol. Four observers performed the validated reproducible measurements of tibial torsion in degrees, based on standardized techniques. The Intra-Class Coefficient (ICC) was calculated to evaluate intra- and inter-observer reliability. The intra- and inter-observer reliability was categorized according to Landis and Koch. Results: Intra-observer reliability for quantification of rotational malalignment on post-operative CT after IMN of tibial shaft fractures was excellent with 0.95 (95% CI = 0.92-0.97). The overall inter-observer reliability was 0.90 (95% CI= 0.87-0.92), also excellent according Landis and Koch. Conclusion: Firstly, bilateral post-operative low-dose -similar radiation exposure as plain chest radiographs- CT assessment of tibial rotational alignment is a reliable diagnostic imaging modality to assess rotational malalignment in patients following IMN of tibial shaft fractures and it allows for early revision surgery. Secondly, it may contribute to our understanding of the incidence-, predictors- and clinical relevance of post-operative tibial rotational malalignment in patients treated with IMN for a tibial shaft fracture, and facilitates future studies on this topic. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1895 / 1900
页数:6
相关论文
共 32 条
[1]  
CLEMENTZ BG, 1989, CLIN ORTHOP RELAT R, P199
[2]   Alignment After Intramedullary Nailing of Distal Tibia Fractures Without Fibula Fixation [J].
De Giacomo, Anthony F. ;
Tornetta, Paul, III .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (10) :561-567
[3]   Measuring femoral and rotational alignment: EOS system versus computed tomography [J].
Folinais, D. ;
Thelen, P. ;
Delin, C. ;
Radier, C. ;
Catonne, Y. ;
Lazennec, J. Y. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (05) :509-516
[4]   Getting the Rotation Right: Techniques for Assessing Rotation in Intramedullary Tibial and Femoral Nailing [J].
Hak, David J. .
ORTHOPEDICS, 2011, 34 (01) :33-36
[5]   Ultrasound measurements of torsions in the tibia and femur [J].
Hudson, D ;
Royer, T ;
Richards, J .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (01) :138-143
[6]   Rotational malalignment after fractures of the femur [J].
Jaarsma, RL ;
van Kampen, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (08) :1100-1104
[7]   Computed tomography determined femoral torsion is not accurate [J].
Jaarsma, RL ;
Bruggeman, AWA ;
Pakvis, DFM ;
Verdonschot, N ;
Lemmens, JAM ;
van Kampen, A .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (08) :552-554
[8]   Malrotation following reamed intramedullary nailing of closed tibial fractures [J].
Jafarinejad, Adel Ebrahimpour ;
Bakhshi, Hooman ;
Haghnegahdar, Maryam ;
Ghomeishi, Nima .
INDIAN JOURNAL OF ORTHOPAEDICS, 2012, 46 (03) :312-316
[9]   TIBIAL TORSION CALCULATED BY COMPUTERIZED-TOMOGRAPHY AND COMPARED TO OTHER METHODS OF MEASUREMENT [J].
JAKOB, RP ;
HAERTEL, M ;
STUSSI, E .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1980, 62 (02) :238-242
[10]  
Jeanmart L, 1983, COMPUTER TOMOGRAPHY, V3, P171