Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study

被引:10
|
作者
Starek, Zdenek [1 ,2 ]
Lehar, Frantisek [1 ,2 ]
Jez, Jiri [1 ,2 ]
Pesl, Martin [1 ,2 ,3 ]
Neuzil, Petr [4 ]
Sediva, Lucie [4 ]
Petru, Jan [4 ]
Dujka, Libor [4 ]
Funasako, Moritoshi [4 ]
Kautzner, Josef [5 ,6 ]
Peichl, Petr [5 ]
Aldhoon, Bashar [5 ]
Albenque, Jean-Paul [7 ]
Combes, Stephane [7 ]
Boveda, Serge [7 ,8 ]
Dukkipati, Srinivas R. [9 ]
Reddy, Vivek Y. [9 ]
机构
[1] St Annes Univ Hosp Brno, Intervent Cardiac Electrophysiol Grp, Int Clin Res Ctr, Pekarska 53, Brno 65691, Czech Republic
[2] Masaryk Univ, St Annes Hosp, Dept Internal Med Cardioangiol 1, Pekarska 53, Brno 65691, Czech Republic
[3] Masaryk Univ, Dept Biol, Fac Med, Kamenice 753-5, Brno 62500, Czech Republic
[4] Homolce Hosp, Dept Cardiol, Roentgenova 2, Prague 15030, Czech Republic
[5] Inst Clin & Expt Med, Dept Cardiol, Videnska 1958-9, Prague 14021 4, Czech Republic
[6] Palacky Univ Hosp, Dept Med 1, Olomouc, Czech Republic
[7] Clin Pasteur, Cardiol Heart Rhythm Management Dept, 45 Ave Lombez, F-31076 Toulouse, France
[8] Vrije Univ Brussel VUB, Univ Ziekenhuis, Laarbeeklaan 101, B-1090 Brussels, Belgium
[9] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, One Gustave L Levy Pl,Box 1030, New York, NY 10029 USA
关键词
Catheter radiofrequency ablation; Atrial fibrillation; Diamond tip irrigated catheter; Temperature contol ablation; High-resolution electrograms; Safety and efficacy; CONTACT FORCE; CATHETER ABLATION; RISK-FACTORS; FOLLOW-UP; CRYOBALLOON; MANAGEMENT; TRIAL;
D O I
10.1007/s10840-021-00986-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and purpose Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. Methods The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 degrees C, max 50 W). Acute and chronic efficacy and safety was evaluated. Results Seventy-one patients (age 69.9 +/- 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 +/- 6.1 min and 20.6 +/- 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). Conclusion This first inman series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA.
引用
收藏
页码:375 / 381
页数:7
相关论文
共 50 条
  • [41] Cryoballoon antral pulmonary vein isolation vs contact force-sensing radiofrequency catheter ablation for pulmonary vein and posterior left atrial isolation in patients with persistent atrial fibrillation
    Yokokawa, Miki
    Chugh, Aman
    Latchamsetty, Rakesh
    Ghanbari, Hamid
    Crawford, Thomas
    Jongnarangsin, Krit
    Cunnane, Ryan
    Saeed, Mohammed
    Sunkara, Bipin
    Tezcan, Mehmet
    Bogun, Frank
    Pelosi, Frank, Jr.
    Morady, Fred
    Oral, Hakan
    HEART RHYTHM, 2018, 15 (12) : 1835 - 1841
  • [42] Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation
    Rypko J. Beukema
    Arif Elvan
    Jaap Jan J. Smit
    Peter Paul H. M. Delnoy
    Anand R. Ramdat Misier
    Vivek Reddy
    Journal of Interventional Cardiac Electrophysiology, 2012, 34 : 143 - 152
  • [43] Novel cryoballoon ablation system for pulmonary vein isolation: multicenter assessment of efficacy and safety-ANTARCTICA study
    Heeger, Christian H.
    Pott, Alexander
    Sohns, Christian
    Riesinger, Lisa
    Sommer, Philipp
    Gasperetti, Alessio
    Tondo, Claudio
    Fassini, Gaetano
    Moser, Fabian
    Lucas, Philipp
    Weinmann, Karolina
    Bohnen, Jan Eric
    Dahme, Tillman
    Rillig, Andreas
    Kuck, Karl Heinz
    Wakili, Reza
    Metzner, Andreas
    Tilz, Roland R.
    EUROPACE, 2022, 24 (12): : 1917 - 1925
  • [44] Positive left atrial remodeling in patients with paroxysmal atrial fibrillation after a successful radiofrequency pulmonary vein isolation
    Wieczorek, Joanna
    Mizia-Stec, Katarzyna
    Cichon, Malgorzata
    Wieczorek, Piotr
    Wozniak-Skowerska, Iwona
    Hoffmann, Andrzej
    Wnuk-Wojnar, Anna M.
    Szydlo, Krzysztof
    KARDIOLOGIA POLSKA, 2023, 81 (7-8) : 737 - 745
  • [45] Efficacy and safety of percutaneous endobilliary radiofrequency ablation with a novel temperature-controlled catheter in malignant biliary strictures
    Yildirim, Gulsah
    Karakas, Hakki Muammer
    POLISH JOURNAL OF RADIOLOGY, 2022, 87 : E487 - E493
  • [46] A Lattice-Tip Temperature-Controlled Radiofrequency Ablation Catheter Durability of Pulmonary Vein Isolation and Linear Lesion Block
    Reddy, Vivek Y.
    Neuzil, Petr
    Peichl, Petr
    Rackauskas, Gediminas
    Anter, Elad
    Petru, Jan
    Funasako, Moritoshi
    Minami, Kentaro
    Aidietis, Audrius
    Marinskis, Germanas
    Natale, Andrea
    Nakagawa, Hiroshi
    Jackman, Warren M.
    Kautzner, Josef
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (06) : 623 - 635
  • [47] Incremental value of isolating the right inferior pulmonary vein during pulmonary vein isolation procedures in patients with paroxysmal atrial fibrillation
    Oral, H
    Chugh, A
    Scharf, C
    Hall, B
    Cheung, P
    Veerareddy, S
    Good, E
    Pelosi, F
    Morady, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (04): : 480 - 484
  • [48] Focal Impulse and Rotor Modulation Ablation vs. Pulmonary Vein isolation for the treatment of paroxysmal Atrial Fibrillation: results from the FIRMAP AF study
    Tilz, Roland R.
    Lenz, Corinna
    Sommer, Philipp
    Roza, Meyer-Saraei
    Sarver, Anne E.
    Williams, Christopher G.
    Heeger, Christian
    Hindricks, Gerhard
    Vogler, Julia
    Eitel, Charlotte
    EUROPACE, 2021, 23 (05): : 722 - 730
  • [49] Utility of Esophageal Temperature Monitoring During Pulmonary Vein Isolation for Atrial Fibrillation Using Duty-Cycled Phased Radiofrequency Ablation
    Deneke, Thomas
    Buenz, Kathrin
    Bastian, Annely
    Paesler, Marcus
    Anders, Helge
    Lehmann, Rainer
    Meuser, Wolfgang
    de Groot, Joris R.
    Horlitz, Marc
    Haberkorn, Ron
    Muegge, Andreas
    Shin, Dong-In
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (03) : 255 - 261
  • [50] Conduction recovery in patients with recurrent atrial fibrillation after pulmonary vein isolation using multi-electrode duty cycled radiofrequency ablation
    Balt, J. C.
    Karadavut, S.
    Mulder, A. A. W.
    Luermans, J. G. L. M.
    Wijffels, M. C. E. F.
    Boersma, L. V. A.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2013, 37 (02) : 197 - 204