The potential for reduced radiation dose from deep learning-based CT image reconstruction A comparison with filtered back projection and hybrid iterative reconstruction using a phantom

被引:19
作者
Lee, Ji Eun [1 ]
Choi, Seo-Youn [1 ]
Hwang, Jeong Ah [2 ,3 ]
Lim, Sanghyeok [1 ]
Lee, Min Hee [1 ]
Ha Yi, Boem [1 ]
Cha, Jang Gyu [1 ]
机构
[1] Soonchunhyang Univ, Bucheon Hosp, Dept Radiol, Coll Med, 170 Jomaru Ro, Bucheon 420767, Gyeonggido, South Korea
[2] Sungkyunkwan Univ, Sch Med, Dept Radiol, Seoul, South Korea
[3] Sungkyunkwan Univ, Ctr Imaging Sci, Samsung Med Ctr, Sch Med, Seoul, South Korea
关键词
artificial intelligence; CT; dose reduction; image reconstruction; CANCER-RISKS; QUALITY; OPTIMIZATION; IMPACT;
D O I
10.1097/MD.0000000000025814
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this phantom study is to compare radiation dose and image quality of abdominal computed tomography (CT) scanned with different tube voltages and tube currents, reconstructed with filtered back projection (FBP), hybrid iterative reconstruction (IR) and deep learning image reconstruction (DLIR) algorithms. A total of 15 CT scans of whole body phantoms were taken with 3 different tube voltages and 5 different tube currents. The images were reconstructed with FBP, 30% and 50% hybrid IR adaptive statistical iterative reconstruction (ASIR-V), and low, medium and high strength DLIR algorithms. The image scanned with tube voltage/tube current of 120 kV/ 200 mA and reconstructed with FBP algorithm was chosen as the reference image. Five radiologists independently analyzed the images individually and also compared it with the reference image in overall, using the visual grading analysis. The mean score of each image was calculated and compared. Using DLIR algorithms, the radiation dose was reduced by 65.5% to 68.1% compared with the dose used in the reference image, while maintaining comparable image quality. Using the DLIR algorithm of medium strength, the image quality was even better than the reference image with a reduced radiation dose up to 36.2% to 50.0%. The DLIR algorithms generated better quality images than ASIR-V algorithms in all the data sets. In addition, among the data sets reconstructed with DLIR algorithms, image quality was the best at the medium strength level, followed by low and high. This phantom study suggests that DLIR algorithms may be considered as a new reconstruction technique by reducing radiation dose while maintaining the image quality of abdominal CTs.
引用
收藏
页数:8
相关论文
共 29 条
[1]   Visual grading characteristics (VGC) analysis:: a non-parametric rank-invariant statistical method for image quality evaluation [J].
Bath, M. ;
Mansson, L. G. .
BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (951) :169-176
[2]  
Brenner David J., 2010, Reviews on Environmental Health, V25, P63
[3]   Image quality comparison of two adaptive statistical iterative reconstruction (ASiR, ASiR-V) algorithms and filtered back projection in routine liver CT [J].
Chen, Li-Hong ;
Jin, Chao ;
Li, Jian-Ying ;
Wang, Ge-Liang ;
Jia, Yong-Jun ;
Duan, Hai-Feng ;
Pan, Ning ;
Guo, Jianxin .
BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1088)
[4]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[5]  
Furlow Bryant, 2010, Radiol Technol, V81, P437
[6]   Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT [J].
Gaddikeri, S. ;
Andre, J. B. ;
Benjert, J. ;
Hippe, D. S. ;
Anzai, Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) :391-396
[7]   State of the Art: Iterative CT Reconstruction Techniques [J].
Geyer, Lucas L. ;
Schoepf, U. Joseph ;
Meinel, Felix G. ;
Nance, John W., Jr. ;
Bastarrika, Gorka ;
Leipsic, Jonathon A. ;
Paul, Narinder S. ;
Rengo, Marco ;
Laghi, Andrea ;
De Cecco, Carlo N. .
RADIOLOGY, 2015, 276 (02) :338-356
[8]   Dose reduction with iterative reconstruction in multi-detector CT: What is the impact on deformation of circular structures in phantom study? [J].
Greffier, J. ;
Macri, F. ;
Larbi, A. ;
Fernandez, A. ;
Pereira, F. ;
Mekkaoui, C. ;
Beregi, J. -P. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2016, 97 (02) :187-196
[9]   Image quality and dose reduction opportunity of deep learning image reconstruction algorithm for CT: a phantom study [J].
Greffier, Joel ;
Hamard, Aymeric ;
Pereira, Fabricio ;
Barrau, Corinne ;
Pasquier, Hugo ;
Beregi, Jean Paul ;
Frandon, Julien .
EUROPEAN RADIOLOGY, 2020, 30 (07) :3951-3959
[10]   Cancer risks from diagnostic radiology [J].
Hall, E. J. ;
Brenner, D. J. .
BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (965) :362-378