Spatial confinement of laser-induced plasma to enhance LIBS sensitivity for trace elements determination in soils

被引:153
作者
Popov, Andrey M. [1 ]
Colao, Francesco [2 ]
Fantoni, Roberta [2 ]
机构
[1] Moscow MV Lomonosov State Univ, Dept Chem, Moscow, Russia
[2] ENEA, I-00044 Frascati, RM, Italy
基金
俄罗斯基础研究基金会;
关键词
INDUCED BREAKDOWN SPECTROSCOPY; ENVIRONMENTAL-SAMPLES; MAGNETIC-FIELD; HEAVY-METALS; IN-SITU; ABLATION; DEPTH; LEAD;
D O I
10.1039/b919485a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
To improve analytical figures-of-merit of the single-pulse LIBS for determination of trace elements in soil samples, a new configuration for spatial confinement based on a special designed device described recently in our work (A.M. Popov, F. Colao and R. Fantoni, J. Anal. At. Spectrom., 2009, 24, 602-604) was studied. The confinement tool realized is a small chamber (about 4 mm in diameter) equipped with polished brass walls and high efficiency collecting optics. A specific analytical procedure was developed to clean the chamber from impurities of microparticles deposited on surface of its walls after each experiment. Investigating the influence of focusing conditions on the stability of LIBS emission signal we have found that the relative standard deviation (RSD) of LIBS signal decreased as the distance between the focus position and the sample surface increased. So, the optimal position of the focus was found below the sample surface as a compromise between the need of collecting intense emission signals and of avoiding breakdown from the ejected microparticles. A significant intensity enhancement was observed inside the chamber, its use as an analytical tool was deeply investigated. The intensity enhancement, obtained on several major (Fe, Mg, Si) and trace elements (As, Ba, Cr, Hg, Mn, Ni, P, Pb, Ti, V) in the examined samples was significantly larger than the decrease of signal-to-noise ratio associated with the slightly worst statistics in the reproducibility of single-shot spectra inside the chamber. The 3 sigma-limits of detection (LOD) of As, Hg, Pb, Mn, V and Ba in soil by using the confined plasma were 30, 25, 90, 140, 1 and 50 ppm, respectively, resulting 2-5 times lower than LODs obtained for a free-expanding plasma under the same experimental conditions.
引用
收藏
页码:837 / 848
页数:12
相关论文
共 47 条
[1]  
ALEXANDER DR, 1996, DACA3995K0053 USACE
[2]   Characterization of laser-ablation plasmas [J].
Amoruso, S ;
Bruzzese, R ;
Spinelli, N ;
Velotta, R .
JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 1999, 32 (14) :R131-R172
[3]   Double pulse laser ablation and plasma: Laser induced breakdown spectroscopy signal enhancement [J].
Babushok, V. I. ;
DeLucia, F. C., Jr. ;
Gottfried, J. L. ;
Munson, C. A. ;
Miziolek, A. W. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (09) :999-1014
[4]   New approach to online monitoring of the Al depth profile of the hot-dip galvanised sheet steel using LIBS [J].
Balzer, H ;
Hoehne, M ;
Noll, R ;
Sturm, V .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (02) :225-233
[5]   EXPANSION OF A RESISTIVE PLASMOID IN A MAGNETIC FIELD [J].
BHADRA, DK .
PHYSICS OF FLUIDS, 1968, 11 (01) :234-&
[6]   Analysis of lead and sulfur in environmental samples by double pulse laser induced breakdown spectroscopy [J].
Burakov, V. S. ;
Tarasenko, N. V. ;
Nedelko, M. I. ;
Kononov, V. A. ;
Vasilev, N. N. ;
Isakov, S. N. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (02) :141-146
[7]   Application of emission spectrometer with laser sampler to microanalysis of pigments from Hubert Robert's canvas painting [J].
Burakov, Victor ;
Kiris, Vasilii ;
Klyachkovskaya, Alena ;
Kozhukh, Natalia ;
Raikov, Sergei .
MICROCHIMICA ACTA, 2006, 156 (3-4) :337-342
[8]   Determination of heavy metals in soils by laser induced breakdown spectroscopy [J].
Capitelli, F ;
Colao, F ;
Provenzano, MR ;
Fantoni, R ;
Brunetti, G ;
Senesi, N .
GEODERMA, 2002, 106 (1-2) :45-62
[9]   Effect of laser-induced crater depth in laser-induced breakdown spectroscopy emission features [J].
Corsi, M ;
Cristoforetti, G ;
Hidalgo, M ;
Iriarte, D ;
Legnaioli, S ;
Palleschi, V ;
Salvetti, A ;
Tognoni, E .
APPLIED SPECTROSCOPY, 2005, 59 (07) :853-860
[10]  
CORTES J, 1996, IRRP964 USACE