Liquid chromatographic method development for steroids determination (corticoids and anabolics) Application to animal feed samples

被引:13
|
作者
Gonzalo-Lumbreras, R.
Muniz-Valencia, R.
Santos-Montes, A.
Izquierdo-Hornillos, R. [1 ]
机构
[1] Univ Complutense, Fac Ciencias Quim, Dept Quim Analit, Madrid 28040, Spain
[2] Univ Pontificia Comillas, Escuela Tecn Super Ingn, Dept Ingn Mecan, Madrid 28015, Spain
关键词
steroids; reversed-phase columns; animal feed;
D O I
10.1016/j.chroma.2007.01.095
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A LC isocratic separation study of a complex mixture containing 18 steroids (corticoids and anabolics), used potentially as growth promoters, was carried out. For this purpose, using a Hypersil ODS column at controlled temperature, mobile phases (from binary to quaternary) prepared from water and MeOH, ACN or THF as organic modifiers and UV detection at 245 nm, were employed (dehydroepiandrosterone was detected at 200 nm). The optimum separation was achieved using water/acetonitrile (65:35, v/v) as mobile phase at 30 degrees C, allowing the separation of 16 out of 18 steroids in about 30 min. The retention scale using optimized binary mobile phases was related with steroids hydrophobicity and structure, allowing a classification into three groups for these compounds. To improve the separation several alkyl-silica packings were tested: Type A (Lichrospher C8) and Type B (Luna C18, Kromasil C18, Purospher C18 and Synergy C12). Taking into account resolution, number of separated compounds and run time analysis the Hypersil column was selected as the best choice for further applications. Calibration graphs were obtained using fluorocortisone, fluoxymesterone or methylprednisolone as internal standard. The optimized separation was applied to the analysis of piglet feed samples spiked with steroids. The sample preparation process included solvent extraction using diethyleter and solid phase extraction using silica cartridges. The recoveries were in the range 70-92%. Decision limits and detection capability were in the range 34-198 and 41-249 mu g/kg, respectively. Repeatability was also evaluated. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 50 条
  • [41] Development and Validation of an Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Determination of Four Type B Trichothecenes and Masked Deoxynivalenol in Various Feed Products
    Fan, Zhichen
    Bai, Bing
    Jin, Peng
    Fan, Kai
    Guo, Wenbo
    Zhao, Zhihui
    Han, Zheng
    MOLECULES, 2016, 21 (06)
  • [42] An automated method on analysis of blood steroids using liquid chromatography tandem mass spectrometry: Application to population screening for congenital adrenal hyperplasia in newborns
    Dhillon, Kuldeep
    Ho, Thomson
    Rich, Patti
    Xu, Dadong
    Lorey, Fred
    She, Jianwen
    Bhandal, Ajit
    CLINICA CHIMICA ACTA, 2011, 412 (23-24) : 2076 - 2084
  • [43] Development and application of a high-throughput sample cleanup process based on 96-well plate for simultaneous determination of 16 steroids in biological matrices using liquid chromatography–triple quadrupole mass spectrometry
    Guanzhong Luo
    Youxin Li
    James J. Bao
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1137 - 1149
  • [44] Determination of testosterone in serum and saliva by liquid chromatography-tandem mass spectrometry: An accurate and sensitive method applied on clinical and forensic samples
    Lood, Yvonne
    Aardal, Elisabeth
    Ahlner, Johan
    Arlemalm, Andreas
    Carlsson, Bjorn
    Ekman, Bertil
    Wahlberg, Jeanette
    Josefsson, Martin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 195
  • [45] Development and validation of a method for determination of 17 endocrine disrupting chemicals in milk, water, blood serum and feed by UHPLC-MS/MS
    Di Marco Pisciottano, Ilaria
    Albrizio, Stefania
    Guadagnuolo, Grazia
    Gallo, Pasquale
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2022, 39 (10): : 1744 - 1758
  • [46] Development and application of a high-throughput sample cleanup process based on 96-well plate for simultaneous determination of 16 steroids in biological matrices using liquid chromatography-triple quadrupole mass spectrometry
    Luo, Guanzhong
    Li, Youxin
    Bao, James J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (04) : 1137 - 1149
  • [47] Development of an extraction method for anabolic androgenic steroids in dietary supplements and analysis by gas chromatography-mass spectrometry: Application for doping-control
    Dahmani, Hajer
    Louati, Kaouthar
    Hajri, Adel
    Bahri, Senda
    Safta, Fathi
    STEROIDS, 2018, 138 : 134 - 160
  • [48] Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development - I. Application to 14 different samples using computer simulation
    Dolan, JW
    Snyder, LR
    Djordjevic, NM
    Hill, DW
    Saunders, DL
    Van Heukelem, L
    Waeghe, TJ
    JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) : 1 - 31
  • [49] Development and validation of stable-isotope dilution liquid chromatography-tandem mass spectrometric method for determination of salivary progesterone
    Higashi, Tatsuya
    Ito, Koichi
    Narushima, Misato
    Sugiura, Takahiro
    Inagaki, Shinsuke
    Min, Jun Zhe
    Toyo'oka, Toshimasa
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (11) : 1175 - 1180
  • [50] Improvement and extension to new analytes of a multi-residue method for the determination of pesticides in cereals and dry animal feed using gas chromatography-tandem quadrupole mass spectrometry revisited
    Walorczyk, Stanislaw
    Drozdzynski, Dariusz
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1251 : 219 - 231