Liquid chromatographic method development for steroids determination (corticoids and anabolics) Application to animal feed samples

被引:13
|
作者
Gonzalo-Lumbreras, R.
Muniz-Valencia, R.
Santos-Montes, A.
Izquierdo-Hornillos, R. [1 ]
机构
[1] Univ Complutense, Fac Ciencias Quim, Dept Quim Analit, Madrid 28040, Spain
[2] Univ Pontificia Comillas, Escuela Tecn Super Ingn, Dept Ingn Mecan, Madrid 28015, Spain
关键词
steroids; reversed-phase columns; animal feed;
D O I
10.1016/j.chroma.2007.01.095
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A LC isocratic separation study of a complex mixture containing 18 steroids (corticoids and anabolics), used potentially as growth promoters, was carried out. For this purpose, using a Hypersil ODS column at controlled temperature, mobile phases (from binary to quaternary) prepared from water and MeOH, ACN or THF as organic modifiers and UV detection at 245 nm, were employed (dehydroepiandrosterone was detected at 200 nm). The optimum separation was achieved using water/acetonitrile (65:35, v/v) as mobile phase at 30 degrees C, allowing the separation of 16 out of 18 steroids in about 30 min. The retention scale using optimized binary mobile phases was related with steroids hydrophobicity and structure, allowing a classification into three groups for these compounds. To improve the separation several alkyl-silica packings were tested: Type A (Lichrospher C8) and Type B (Luna C18, Kromasil C18, Purospher C18 and Synergy C12). Taking into account resolution, number of separated compounds and run time analysis the Hypersil column was selected as the best choice for further applications. Calibration graphs were obtained using fluorocortisone, fluoxymesterone or methylprednisolone as internal standard. The optimized separation was applied to the analysis of piglet feed samples spiked with steroids. The sample preparation process included solvent extraction using diethyleter and solid phase extraction using silica cartridges. The recoveries were in the range 70-92%. Decision limits and detection capability were in the range 34-198 and 41-249 mu g/kg, respectively. Repeatability was also evaluated. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 50 条
  • [21] Solid-phase extraction and high performance liquid chromatographic determination of steroids adulterated in traditional Chinese medicines
    Ku, YR
    Wen, KC
    Ho, LK
    Chang, YS
    JOURNAL OF FOOD AND DRUG ANALYSIS, 1999, 7 (02) : 123 - 130
  • [22] Simultaneous determination of sulfadiazine and trimethoprim in animal feed by liquid chromatography with UV and tandem mass spectrometric detection
    Croubels, S
    Wassink, P
    De Backer, P
    ANALYTICA CHIMICA ACTA, 2002, 473 (1-2) : 183 - 194
  • [23] DIRECT DETERMINATION OF COPPER AT TRACE LEVELS IN SOLID SAMPLES OF ANIMAL FEED USING ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    ANZANO, JM
    MARTINEZGARBAYO, MP
    BELARRA, MA
    CASTILLO, JR
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (02) : 125 - 128
  • [24] Determination of eleven coccidiostats in animal feed by liquid chromatography-tandem mass spectrometry at cross contamination levels
    Cronly, Mark
    Behan, P.
    Foley, B.
    Malone, E.
    Shearan, P.
    Regan, L.
    ANALYTICA CHIMICA ACTA, 2011, 700 (1-2) : 26 - 33
  • [25] Determination of antibacterials in animal feed by pressurized liquid extraction followed by online purification and liquid chromatography-electrospray tandem mass spectrometry
    Lina Kantiani
    Marinella Farré
    Josep Manuel Grases i Freixiedas
    Damià Barceló
    Analytical and Bioanalytical Chemistry, 2010, 398 : 1195 - 1205
  • [26] Determination of antibacterials in animal feed by pressurized liquid extraction followed by online purification and liquid chromatography-electrospray tandem mass spectrometry
    Kantiani, Lina
    Farre, Marinella
    Manuel Grases i Freixiedas, Josep
    Barcelo, Damia
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (03) : 1195 - 1205
  • [27] Interlaboratory validation of an LC-MS/MS method for the determination of melamine and cyanuric acid in animal feed
    Fry, Hildburg
    Mietle, Kerstin
    Maehnert, Eileen
    Zinke, Sebastian
    Schwieters, Mandy
    Pydde, Emanuele
    Preiss-Weigert, Angelika
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2017, 34 (08): : 1320 - 1332
  • [28] Development of HPLC-UV method for detection and quantification of seven organic acids in animal feed
    Kim, Jin Kug
    Lee, Mi Jin
    Lee, Ye Ji
    Kim, Hye Jin
    Jeong, Min Hee
    Kim, Ho Jin
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2016, 29 (04) : 202 - 208
  • [29] Development of an immunoaffinity chromatography and HPLC-UV method for determination of 16 sulfonamides in feed
    Kim, Ho Jin
    Jeong, Min Hee
    Park, Hye Jin
    Kim, Won Chan
    Kim, Jang Eok
    FOOD CHEMISTRY, 2016, 196 : 1144 - 1149
  • [30] Gas chromatographic-tandem mass spectrometric determination of anabolic steroids and their esters in hair -: Application in doping control and meat quality control
    Gaillard, Y
    Vayssette, F
    Balland, A
    Pépin, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1999, 735 (02): : 189 - 205