Liquid chromatographic method development for steroids determination (corticoids and anabolics) Application to animal feed samples

被引:13
|
作者
Gonzalo-Lumbreras, R.
Muniz-Valencia, R.
Santos-Montes, A.
Izquierdo-Hornillos, R. [1 ]
机构
[1] Univ Complutense, Fac Ciencias Quim, Dept Quim Analit, Madrid 28040, Spain
[2] Univ Pontificia Comillas, Escuela Tecn Super Ingn, Dept Ingn Mecan, Madrid 28015, Spain
关键词
steroids; reversed-phase columns; animal feed;
D O I
10.1016/j.chroma.2007.01.095
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A LC isocratic separation study of a complex mixture containing 18 steroids (corticoids and anabolics), used potentially as growth promoters, was carried out. For this purpose, using a Hypersil ODS column at controlled temperature, mobile phases (from binary to quaternary) prepared from water and MeOH, ACN or THF as organic modifiers and UV detection at 245 nm, were employed (dehydroepiandrosterone was detected at 200 nm). The optimum separation was achieved using water/acetonitrile (65:35, v/v) as mobile phase at 30 degrees C, allowing the separation of 16 out of 18 steroids in about 30 min. The retention scale using optimized binary mobile phases was related with steroids hydrophobicity and structure, allowing a classification into three groups for these compounds. To improve the separation several alkyl-silica packings were tested: Type A (Lichrospher C8) and Type B (Luna C18, Kromasil C18, Purospher C18 and Synergy C12). Taking into account resolution, number of separated compounds and run time analysis the Hypersil column was selected as the best choice for further applications. Calibration graphs were obtained using fluorocortisone, fluoxymesterone or methylprednisolone as internal standard. The optimized separation was applied to the analysis of piglet feed samples spiked with steroids. The sample preparation process included solvent extraction using diethyleter and solid phase extraction using silica cartridges. The recoveries were in the range 70-92%. Decision limits and detection capability were in the range 34-198 and 41-249 mu g/kg, respectively. Repeatability was also evaluated. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:321 / 330
页数:10
相关论文
共 50 条
  • [1] Sample preparation for the determination of steroids (corticoids and anabolics) in feed using LC
    Muniz-Valencia, Roberto
    Ceballos-Magana, Silvia G.
    Gonzalo-Lumbreras, Raquel
    Santos-Montes, Ana
    Izquierdo-Hornillos, Roberto C.
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (12) : 2303 - 2309
  • [2] Liquid chromatographic method development for anabolic androgenic steroids using a monolithic column.: Application to animal feed samples
    Muniz-Valencia, R.
    Gonzalo-Lumbreras, R.
    Santos-Montes, A.
    Izquierdo-Hornillos, R.
    ANALYTICA CHIMICA ACTA, 2008, 611 (01) : 103 - 112
  • [3] Method development validation for corticoids in animal feed samples by liquid chromatography using a monolithic column
    Muniz-Valencia, Roberto
    Gonzalo-Lumbreras, Raquel
    Santos-Montes, Ana
    Izquierdo-Hornillos, Roberto
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (17) : 2950 - 2957
  • [4] A liquid chromatography method using a monolithic column for the determination of corticoids in animal feed and animal feeding water
    Muniz-Valencia, R.
    Ceballos-Magana, S. G.
    Gonzalo-Lumbreras, R.
    Santos-Montes, A.
    Izquierdo-Hornillos, R.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (07) : 2683 - 2691
  • [5] A liquid chromatography method using a monolithic column for the determination of corticoids in animal feed and animal feeding water
    R. Muñiz-Valencia
    S. G. Ceballos-Magaña
    R. Gonzalo-Lumbreras
    A. Santos-Montes
    R. Izquierdo-Hornillos
    Analytical and Bioanalytical Chemistry, 2008, 391
  • [6] Method development and validation for melamine and its derivatives in rice concentrates by liquid chromatography.: Application to animal feed samples
    Muniz-Valencia, Roberto
    Ceballos-Magana, Silvia G.
    Rosales-Martinez, Daniel
    Gonzalo-Lumbreras, Raquel
    Santos-Montes, Ana
    Cubedo-Fernandez-Trapiella, Angel
    Izquierdo-Hornillos, Roberto C.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 392 (03) : 523 - 531
  • [7] Method development and validation for melamine and its derivatives in rice concentrates by liquid chromatography. Application to animal feed samples
    Roberto Muñiz-Valencia
    Silvia G. Ceballos-Magaña
    Daniel Rosales-Martinez
    Raquel Gonzalo-Lumbreras
    Ana Santos-Montes
    Angel Cubedo-Fernandez-Trapiella
    Roberto C. Izquierdo-Hornillos
    Analytical and Bioanalytical Chemistry, 2008, 392 : 523 - 531
  • [8] Development and Validation of Analytical Method for Clenbuterol Chiral Determination in Animal Feed by Direct Liquid Chromatography
    Noelia Rosales-Conrado
    María Eugenia de León-González
    Luis María Polo-Díez
    Food Analytical Methods, 2015, 8 : 2647 - 2659
  • [9] Development and Validation of Analytical Method for Clenbuterol Chiral Determination in Animal Feed by Direct Liquid Chromatography
    Rosales-Conrado, Noelia
    Eugenia de Leon-Gonzalez, Maria
    Maria Polo-Diez, Luis
    FOOD ANALYTICAL METHODS, 2015, 8 (10) : 2647 - 2659
  • [10] GC-MS method development and validation for anabolic steroids in feed samples
    Muniz-Valencia, Roberto
    Ceballos-Magana, Silvia G.
    Gonzalo-Lumbreras, Raquel
    Santos-Montes, Ana
    Lzquierdo-Hornillos, Roberto
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (04) : 727 - 734