Precision of Post-Traumatic Orbital Reconstruction Using Unsintered Hydroxyapatite Particles/Poly-L-Lactide Composite Bioactive/Resorbable Mesh Plate with and without Navigation: A Retrospective Study

被引:21
作者
Sukegawa, Shintaro [1 ]
Kanno, Takahiro [2 ]
Koyama, Yuta [3 ]
Matsumoto, Kenichi [1 ]
Sukegawa-Takahashi, Yuka [1 ]
Masui, Masanori [1 ]
Tanaka, Shigeto [3 ]
Furuki, Yoshihiko [1 ]
机构
[1] Kagawa Prefectural Cent Hosp, Div Oral & Maxillofacial Surg, 1-2-1 Asahi Cho, Takamatsu, Kagawa 7608557, Japan
[2] Shimane Univ, Dept Oral & Maxillofacial Surg, Fac Med, Izumo, Shimane, Japan
[3] Kagawa Prefectural Cent Hosp, Div Ophthalmol, Takamatsu, Kagawa, Japan
关键词
Orbital fractures; Bioactive/resorbable material; Orbital reconstruction; u-HA/PLLA mesh plate; Intraoperative navigation; VOLUME MEASUREMENT; WALL DEFECTS; FRACTURE RECONSTRUCTION; BLOWOUT FRACTURES; TITANIUM MESH; ENOPHTHALMOS; FIXATION; FLOOR; BONE; BIORESORPTION;
D O I
10.2485/jhtb.26.274
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to assess the level of accuracy that can be achieved in patients undergoing orbital reconstruction for orbital floor defect accompanied by midfacial fracture using an unsintered hydroxyapatite particles/poly-L-lactide composite plate system with and without the use of intraoperative navigation. Eight consecutive patients treated using the u-HA/PLLA mesh plate system between 2014 and 2016 were included in this retrospective study. We analyzed the clinical and radiological data of these patients with orbital floor defect and midfacial fracture extending to the orbit. We examined the patients' postoperative healing status, including visual activity, diplopia, and enophthalmos. The overall volume of the orbit was calculated in cubic millimeter sand was compared between the reconstructed orbit and the uninjured orbit for with and without the use of navigation groups. No patients complained of visual problems, and no further treatment was required postoperatively. Except for one patient with persistence of slight supraversion diplopia in the group without navigation, all the preoperative diplopia symptoms postoperatively improved, and none of the patients complained of problems in daily living. There was a significant difference (p < 0.05) in the mean reconstructed orbital volume accuracy between with and without navigation. In conclusion, complex orbital reconstruction using optimal bioactive/resorbable material with intraoperative navigation is an accurate and reliable method of reconstruction.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 29 条
[1]   Orbital fractures: A new classification and staging of 190 patients [J].
Carinci, Francesco ;
Zollino, Ilaria ;
Brunelli, Giorgio ;
Cenzi, Roberto .
JOURNAL OF CRANIOFACIAL SURGERY, 2006, 17 (06) :1040-1044
[2]   The relationship between enophthalmos, linear displacement, and volume change in experimentally recreated orbital fractures [J].
Cunningham, LL ;
Peterson, GP ;
Haug, RH .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 63 (08) :1169-1173
[3]   Controversies in orbital reconstruction-I. Defect-driven orbital reconstruction: A systematic review [J].
Dubois, L. ;
Steenen, S. A. ;
Gooris, P. J. J. ;
Mourits, M. P. ;
Becking, A. G. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 44 (03) :308-315
[4]   Precision of posttraumatic primary orbital reconstruction using individually bent titanium mesh with and without navigation: a retrospective study [J].
Essig, Harald ;
Dressel, Lars ;
Rana, Majeed ;
Rana, Madiha ;
Kokemueller, Horst ;
Ruecker, Martin ;
Gellrich, Nils-Claudius .
HEAD & FACE MEDICINE, 2013, 9
[5]   Late reconstruction of the complex orbital fractures with computer-aided design and computer-aided manufacturing technique [J].
Fan, Xianqun ;
Zhou, Huifang ;
Lin, Ming ;
Fu, Yao ;
Li, Jin .
JOURNAL OF CRANIOFACIAL SURGERY, 2007, 18 (03) :665-673
[6]   Computer-assisted orbital volume measurement in the surgical correction of late enophthalmos caused by blowout fractures [J].
Fan, XQ ;
Li, J ;
Zhu, J ;
Li, HS ;
Zhang, DS .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 19 (03) :207-211
[7]   Computer-assisted secondary reconstruction of unilateral posttraumatic orbital deformity [J].
Gellrich, NC ;
Schramm, A ;
Hammer, B ;
Rojas, S ;
Cufi, D ;
Lagrèze, W ;
Schmelzeisen, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2002, 110 (06) :1417-1429
[8]   Biomaterials for Repair of Orbital Floor Blowout Fractures: A Systematic Review [J].
Gunarajah, Dharmindra Rajah ;
Samman, Nabil .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) :550-570
[9]   Orbital reconstruction with individually copy-milled ceramic implants [J].
Hoffmann, J ;
Cornelius, CP ;
Groten, M ;
Pröbster, L ;
Pfannenberg, C ;
Schwenzer, N .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 101 (03) :604-612
[10]   Reconstruction of orbital wall defects:: critical review of 72 patients [J].
Jaquiery, C. ;
Aeppli, C. ;
Cornelius, P. ;
Palmowsky, A. ;
Kunz, C. ;
Hammer, B. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 36 (03) :193-199