Intima-Media Thickness: Setting a Standard for a Completely Automated Method of Ultrasound Measurement

被引:109
作者
Molinari, Filippo [1 ]
Zeng, Guang [2 ]
Suri, Jasjit S. [3 ,4 ]
机构
[1] Politecn Torino, Dept Elect, Biolab, Turin, Italy
[2] Mayo Clin, Aging & Dementia Imaging Res Lab, Rochester, MN USA
[3] Biomed Technol Inc, Denver, CO USA
[4] Idaho State Univ, Pocatello, ID USA
关键词
BOUNDARY DETECTION ALGORITHMS; WALL THICKNESS; SEGMENTATION; IMAGES;
D O I
10.1109/TUFFC.2010.1522
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The intima-media thickness (IMT) of the common carotid artery is a widely used clinical marker of severe cardiovascular diseases. IMT is usually manually measured on longitudinal B-mode ultrasound images. Many computer-based techniques for IMT measurement have been proposed to overcome the limits of manual segmentation. Most of these, however, require a certain degree of user interaction. In this paper we describe a new, completely automated layer extraction technique (named CALEXia) for the segmentation and IMT measurement of the carotid wall in ultrasound images. CALEXia is based on an integrated approach consisting of feature extraction, line fitting, and classification that enables the automated tracing of the carotid adventitial walls. IMT is then measured by relying on a fuzzy K-means classifier. We tested CALEXia on a database of 200 images. We compared CALEXia's performance with those of a previously developed methodology that was based on signal analysis (CULEXsa). Three trained operators manually segmented the images and the average profiles were considered as the ground truth. The average error from CALEXia for lumen-intima (LI) and media-adventitia (MA) interface tracings were 1.46 +/- 1.51 pixel (0.091 +/- 0.093 mm) and 0.40 +/- 0.87 pixel (0.025 +/- 0.055 mm), respectively. The corresponding errors for CULEXsa were 0.55 +/- 0.51 pixels (0.035 +/- 0.032 mm) and 0.59 +/- 0.46 pixels (0.037 +/- 0.029 mm). The IMT measurement error was equal to 0.87 +/- 0.56 pixel (0.054 +/- 0.035 mm) for CALEXia and 0.12 +/- 0.14 pixel (0.01 +/- 0.01 mm) for CULEXsa. Thus, CALEXia showed limited performance in segmenting the LI interface, but outperformed CULEXsa in the MA interface and in the number of images correctly processed (190 for CALEXia and 184 for CULEXsa). Based upon two complementary strategies, we anticipate fusing them for further IMT improvements.
引用
收藏
页码:1112 / 1124
页数:13
相关论文
共 21 条
[1]   Comments on:: A methodology for evaluation of boundary detection algorithms on medical images [J].
Alberola-López, C ;
Martín-Fernández, M ;
Ruiz-Alzola, J .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (05) :658-660
[2]   A methodology for evaluation of boundary detection algorithms on medical images [J].
Chalana, V ;
Kim, YM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (05) :642-652
[3]  
CHEN G, 2002, ACM T EMBED COMPUT S, V1, P27, DOI DOI 10.1145/581888.581892
[4]   Measurement of carotid intima-media thickness to assess progression and regression of atherosclerosis [J].
de Groot, Eric ;
van Leuven, Sander I. ;
Duivenvoorden, Raphael ;
Meuwese, Marijn C. ;
Akdim, Fatima ;
Bots, Michiel L. ;
Kastelein, John Jp .
NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (05) :280-288
[5]   Characterization of a completely user-independent algorithm for carotid artery segmentation in 2-D ultrasound images [J].
Delsanto, Silvia ;
Molinari, Filippo ;
Giustetto, Pierangela ;
Liboni, William ;
Badalamenti, Sergio ;
Suri, Jasjit S. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (04) :1265-1274
[6]   Real-time measurement system for evaluation of the carotid intima-media thickness with a robust edge operator [J].
Faita, Francesco ;
Gernignani, Vincenzo ;
Bianchini, Elisabetta ;
Giannarelli, Chiara ;
Ghiadoni, Lorenzo ;
Demi, Marcello .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (09) :1353-1361
[7]   Using the hough transform to segment ultrasound images of longitudinal and transverse sections of the carotid artery [J].
Golemati, Spyretta ;
Stoitsis, John ;
Sifakis, Emmanouil G. ;
Balkizas, Thomas ;
Nikita, Konstantina S. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (12) :1918-1932
[8]   Automatic mea surement of carotid diameter and wall thickness in ultrasound images [J].
Gutierrez, MA ;
Pilon, PE ;
Lage, SG ;
Kopel, L ;
Carvalho, RT ;
Furuie, SS .
COMPUTERS IN CARDIOLOGY 2002, VOL 29, 2002, 29 :359-362
[9]  
Kyriacou E, 2005, ST HEAL T, V113, P241
[10]   A multiscale dynamic programming procedure for boundary detection in ultrasonic artery images [J].
Liang, Q ;
Wendelhag, I ;
Wikstrand, J ;
Gustavsson, T .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (02) :127-142