Calibration of low-temperature ac susceptometers with a copper cylinder standard

被引:21
|
作者
Chen, D. -X. [1 ]
Skumryev, V.
机构
[1] Univ Autonoma Barcelona, ICREA, E-08193 Barcelona, Spain
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2010年 / 81卷 / 02期
关键词
calibration; copper; eddy currents; magnetic susceptibility; magnetic variables measurement; CRITICAL-CURRENT-DENSITY; HIGH-TC SUPERCONDUCTORS; CRITICAL-STATE SUSCEPTIBILITY; DEMAGNETIZING FACTORS; MAGNETIC-SUSCEPTIBILITY; CONDUCTING CYLINDERS; RECTANGULAR PRISMS; BARS; BEHAVIOR; GRAINS;
D O I
10.1063/1.3309779
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-quality low-temperature ac susceptometer is calibrated by comparing the measured ac susceptibility of a copper cylinder with its eddy-current ac susceptibility accurately calculated. Different from conventional calibration techniques that compare the measured results with the known property of a standard sample at certain fixed temperature T, field amplitude H-m, and frequency f, to get a magnitude correction factor, here, the electromagnetic properties of the copper cylinder are unknown and are determined during the calibration of the ac susceptometer in the entire T, H-m, and f range. It is shown that the maximum magnitude error and the maximum phase error of the susceptometer are less than 0.7% and 0.3 degrees, respectively, in the region T=5-300 K and f=111-1111 Hz at H-m=800 A/m, after a magnitude correction by a constant factor as done in a conventional calibration. However, the magnitude and phase errors can reach 2% and 4.3 degrees at 10 000 and 11 Hz, respectively. Since the errors are reproducible, a large portion of them may be further corrected after a calibration, the procedure for which is given. Conceptual discussions concerning the error sources, comparison with other calibration methods, and applications of ac susceptibility techniques are presented.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] A LOW-TEMPERATURE AC MICROCALORIMETER
    MINAKOV, AA
    IEEE TRANSACTIONS ON MAGNETICS, 1994, 30 (02) : 1058 - 1060
  • [2] LOW-TEMPERATURE DIAMAGNETISM OF ELECTRONS IN A CYLINDER
    DINGLE, RB
    PHYSICAL REVIEW, 1953, 92 (05): : 1320 - 1320
  • [3] TEMPERATURE CALIBRATION OF LOW-TEMPERATURE INFRARED CELLS
    FORD, TA
    SETO, PF
    FALK, M
    SPECTROCHIMICA ACTA PART A-MOLECULAR SPECTROSCOPY, 1969, A 25 (09): : 1650 - &
  • [4] Low-temperature AC microcalorimeter and potentialities of the AC technique
    Minakov, Alexander A., 1600, Butterworth-Heinemann Ltd, Oxford, United Kingdom (34):
  • [5] LOW-TEMPERATURE AC CONDUCTIVITY DEVICE
    CHIODELLI, G
    CAMPARI, G
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (01): : 31 - 33
  • [6] LOW-TEMPERATURE RTD CALIBRATION SYSTEM
    Kozlowski, K.
    Malinowski, H.
    Dabrowski, D.
    Malinowski, K.
    Roslon, K.
    XI WORKSHOP ON PARTICLE CORRELATIONS AND FEMTOSCOPY AND NICA DAYS 2015, 2016, 9 (02): : 251 - 255
  • [7] LOW-TEMPERATURE RECRYSTALLIZATION OF COPPER
    GARBER, RI
    GINDIN, IA
    LAZAREV, BG
    STARODUBOV, YD
    SOVIET PHYSICS-SOLID STATE, 1960, 2 (06): : 991 - 993
  • [8] Low-Temperature Bonding of Copper by Copper Electrodeposition
    Fukumoto, Shinji
    Nakamura, Koki
    Takahashi, Makoto
    Tanaka, Yuto
    Takahashi, Shoya
    Matsushima, Michiya
    MATERIALS TRANSACTIONS, 2022, 63 (06) : 783 - 788
  • [9] A LOW-TEMPERATURE ATTACHMENT FOR STANDARD TESTBEDS
    ZINOVEV, MV
    ILICHEV, VY
    KUCHERYA.VA
    PUSTOVAL.VA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1966, (01): : 249 - &
  • [10] A LOW-TEMPERATURE MICROWAVE NOISE STANDARD
    TREMBATH, CL
    WAIT, DF
    ENGEN, GF
    FOOTE, WJ
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1968, MT16 (09) : 709 - +