Feasibility and accuracy of three-dimensional transthoracic echocardiography vs. multidetector computed tomography in the evaluation of aortic valve annulus in patient candidates to transcatheter aortic valve implantation

被引:26
作者
Tamborini, Gloria [1 ]
Fusini, Laura [1 ]
Muratori, Manuela [1 ]
Cefalu, Claudia [1 ]
Gripari, Paola [1 ]
Ali, Sarah Ghulam [1 ]
Pontone, Gianluca [1 ]
Andreini, Daniele [1 ,2 ]
Bartorelli, Antonio L. [1 ,2 ]
Alamanni, Francesco [1 ,2 ]
Fiorentini, Cesare [1 ,2 ]
Pepi, Mauro [1 ]
机构
[1] Ctr Cardiol Monzino IRCCS, I-20138 Milan, Italy
[2] Univ Milan, Cardiovasc Sect, Dept Clin Sci & Community Hlth, Milan, Italy
关键词
Three-dimensional transthoracic echocardiography; Transcatheter aortic valve implantation; Aortic valve stenosis; Multidetector computer tomography; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; PARAVALVULAR REGURGITATION; OUTCOMES; RECOMMENDATIONS; INTERVENTIONS; REPLACEMENT; REGISTRY; IMPACT; CT;
D O I
10.1093/ehjci/jeu157
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Proper measurement of the aortic annulus (AoA) is crucial for the success of transcatheter aortic valve implantation (TAVI). Transthoracic echocardiography (TTE) is the first step to assess AoA diameter, but a two-dimensional TTE (2DTTE) measurement is no longer accepted as the sole determinant of prosthetic size. The aims of the study were to evaluate feasibility and accuracy of three-dimensional TTE (3DTTE) estimation of AoA dimensions in comparison with multidetector computer tomography (MDCT). Methods and results We enrolled 100 consecutive patients referred for TAVI. Feasibility of AoA evaluation was 91% for 3DTTE and in 90% for MDCT. In 81 of 100 patients, AoA maximum diameter (max-D), minimum diameter (min-D), and area were measured and compared using 2DTTE, 3DTTE, and MDCT. Image quality of 3DTTE was sufficient in 47, good in 46 and optimal in 7%. High correlations (P < 0.001) were found between MDCT and 3DTTE (max-D: r = 0.89; min-D r = 0.86; area: r = 0.93), and between MDCT and 2DTTE (min-D: r = 0.81; area 0.78). The 3DTTE measurements were found to be highly reproducible on intra-and interobserver variability analyses. Regarding the choice of prosthesis size, agreement between 3DTTE and MDCT was very good (k = 0.84, P < 0.001) while it was poor between 2DTTE and MDCT (k = 0.36, P < 0.001). Conclusions 3DTTE may be a valid imaging alternative in patients unsuitable for MDCT during the preoperative evaluation for TAVI. Evaluation of AoA through 3DTTE is feasible, and measurements closely approximate those of MDCT thus improving TTE accuracy in identifying the correct prosthesis size.
引用
收藏
页码:1316 / 1323
页数:8
相关论文
共 33 条
  • [1] Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
    Abdel-Wahab, Mohamed
    Zahn, Ralf
    Horack, Martin
    Gerckens, Ulrich
    Schuler, Gerhard
    Sievert, Horst
    Eggebrecht, Holger
    Senges, Jochen
    Richardt, Gert
    [J]. HEART, 2011, 97 (11) : 899 - 906
  • [2] Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation
    Altiok, Ertunc
    Koos, Ralf
    Schroeder, Joerg
    Brehmer, Kathrin
    Hamada, Sandra
    Becker, Michael
    Mahnken, Andreas H.
    Almalla, Mohammad
    Dohmen, Guido
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    [J]. HEART, 2011, 97 (19) : 1578 - 1584
  • [3] 2-Year Follow-Up of Patients Undergoing Transcatheter Aortic Valve Implantation Using a Self-Expanding Valve Prosthesis
    Buellesfeld, Lutz
    Gerckens, Ulrich
    Schuler, Gerhard
    Bonan, Raoul
    Kovac, Jan
    Serruys, Patrick W.
    Labinaz, Marino
    den Heijer, Peter
    Mullen, Michael
    Tymchak, Wayne
    Windecker, Stephan
    Mueller, Ralf
    Grube, Eberhard
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (16) : 1650 - 1657
  • [4] Transcatheter aortic valve implantation: implications of multimodality imaging in patient selection, procedural guidance, and outcomes
    Delgado, Victoria
    Kapadia, Samir
    Schalij, Martin J.
    Schuijf, Joanne D.
    Tuzcu, E. Murat
    Bax, Jeroen J.
    [J]. HEART, 2012, 98 (09) : 743 - 754
  • [5] Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence
    Detaint, Delphine
    Lepage, Laurent
    Himbert, Dominique
    Brochet, Eric
    Messika-Zeitoun, David
    Iung, Bernard
    Vahanian, Alec
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) : 821 - 827
  • [6] Demonstration of left ventricular outflow tract eccentricity by real time 3D echocardiography: Implications for the determination of aortic valve area
    Doddamani, Sanjay
    Bello, Ricardo
    Friedman, Mark A.
    Banerjee, Anita
    Bowers, James H., Jr.
    Kim, Bette
    Vennalaganti, Prashant R.
    Ostfeld, Robert J.
    Gordon, Garet M.
    Malhotra, Divya
    Spevack, Daniel M.
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (08): : 860 - 866
  • [7] Imaging and quantification of aortic regurgitation after TAVI
    Ewe, See Hooi
    Delgado, Victoria
    Bax, Jeroen J.
    [J]. EUROINTERVENTION, 2012, 8 : Q21 - Q30
  • [8] Location and Severity of Aortic Valve Calcium and Implications for Aortic Regurgitation After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Ng, Arnold C. T.
    Schuijf, Joanne D.
    van der Kley, Frank
    Colli, Andrea
    Palmen, Meindert
    de Weger, Arend
    Marsan, Nina Ajmone
    Holman, Eduard R.
    de Roos, Albert
    Schalij, Martin J.
    Bax, Jeroen J.
    Delgado, Victoria
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (10) : 1470 - 1477
  • [9] Recommendations for transoesophageal echocardiography: EACVI update 2014
    Flachskampf, Frank A.
    Wouters, Patrick F.
    Edvardsen, Thor
    Evangelista, Artur
    Habib, Gilbert
    Hoffman, Piotr
    Hoffmann, Rainer
    Lancellotti, Patrizio
    Pepi, Mauro
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (04) : 353 - 365
  • [10] Frailty in older adults: Evidence for a phenotype
    Fried, LP
    Tangen, CM
    Walston, J
    Newman, AB
    Hirsch, C
    Gottdiener, J
    Seeman, T
    Tracy, R
    Kop, WJ
    Burke, G
    McBurnie, MA
    [J]. JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2001, 56 (03): : M146 - M156