Ambient and free-vibration tests to improve the quantification and estimation of modal parameters in existing bridges

被引:43
作者
Lorenzoni, Filippo [1 ]
De Conto, Nicola [1 ]
da Porto, Francesca [1 ]
Modena, Claudio [1 ]
机构
[1] Univ Padua, Dept Geosci, Via Gradenigo 6, I-35131 Padua, Italy
关键词
Damping; Ambient vibration tests; Free vibration tests; System identification; FREQUENCY-DOMAIN; IDENTIFICATION; POSTERIOR;
D O I
10.1007/s13349-019-00357-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The correct estimation of modal parameters has an important role in ensuring the structural reliability of existing bridges. Operational modal analysis provides rather accurate extraction of natural frequency and mode shapes, but the corresponding damping estimates are subjected to higher uncertainties. This paper reports the results of ambient and free-vibration tests performed on five different typologies of road and railway bridges: steel trusses, steel box, multi-girder reinforced concrete, masonry and reinforced concrete arch bridges. In one case, data acquired by a continuous structural health monitoring system over a period of 1 year are available. In another case, the passage of trains is exploited to perform free decays. The processing of ambient vibrations is performed through several frequency and time-domain identification techniques, whereas the measured free decays are analyzed by the logarithmic decrement method applied to the autocorrelation functions of the signals. Outcomes are compared, evaluating the quality of modal damping estimates and the accuracy of results. The influence on modal parameters extraction of structural typologies, length of acquired time histories and ambient noise, loading and environmental effects are studied. At the end, it is demonstrated that the estimation of modal damping is more reliable for flexible structures when SHM and free-vibration data are available.
引用
收藏
页码:617 / 637
页数:21
相关论文
共 24 条
[1]  
Aktan A., 2003, Development of a Model Health Monitoring Guide for Major Bridges
[2]  
Allemang R, 1982, 1 INT MOD AN C BETH
[3]   Fast Bayesian ambient modal identification in the frequency domain, Part I: Posterior most probable value [J].
Au, Siu-Kui .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 26 :60-75
[4]   Fast Bayesian ambient modal identification in the frequency domain, Part II: Posterior uncertainty [J].
Au, Siu-Kui .
MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2012, 26 :76-90
[5]   Fast Bayesian FFT Method for Ambient Modal Identification with Separated Modes [J].
Au, Siu-Kui .
JOURNAL OF ENGINEERING MECHANICS, 2011, 137 (03) :214-226
[6]  
Bajric A., 2015, P 6 INT OP MOD AN C
[7]   Modal identification of output-only systems using frequency domain decomposition [J].
Brincker, R ;
Zhang, LM ;
Andersen, P .
SMART MATERIALS & STRUCTURES, 2001, 10 (03) :441-445
[8]   Ambient vibration re-testing and operational modal analysis of the Humber Bridge [J].
Brownjohn, J. M. W. ;
Magalhaes, Filipe ;
Caetano, Elsa ;
Cunha, Alvaro .
ENGINEERING STRUCTURES, 2010, 32 (08) :2003-2018
[9]   Recent perspectives in dynamic testing and monitoring of bridges [J].
Cunha, A. ;
Caetano, E. ;
Magalhaes, F. ;
Moutinho, C. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2013, 20 (06) :853-877
[10]  
Ewins DJ., 1984, MODAL TESTING THEORY