Quantitative analysis of penicillins in porcine tissues, milk and animal feed using derivatisation with piperidine and stable isotope dilution liquid chromatography tandem mass spectrometry

被引:32
|
作者
van Holthoon, Frederique [1 ]
Mulder, Patrick P. J. [1 ]
van Bennekom, Eric O. [1 ]
Heskamp, Henri [1 ]
Zuidema, Tina [1 ]
van Rhijn, Hans A. [2 ]
机构
[1] RIKILT Inst Food Safety Wageningen UR, NL-6700 AE Wageningen, Netherlands
[2] Food & Consumer Prod Safety Author VWA Lab Reg E, NL-2500 CM Den Iiaag, Netherlands
关键词
Penicillins; Piperidine; Derivatisation; LC-MS/MS; Isotope dilution; Validation; BETA-LACTAM ANTIBIOTICS; SOLID-PHASE EXTRACTION; BOVINE-MILK; ANTIMICROBIAL RESIDUES; DEGRADATION-PRODUCTS; KIDNEY; AMOXICILLIN; MUSCLE; CEPHALOSPORINS; ELUCIDATION;
D O I
10.1007/s00216-010-3523-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Penicillins are used universally in both human and veterinary medicine. The European Union (EU) has established maximum residue levels (MRLs) for most -lactam antibiotics in milk and animal tissues and included them in the National Residue Monitoring Programs. In this study, a novel method is described for the determination and confirmation of eight penicillins in porcine tissues, milk and animal feed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). To prevent degradation of penicillin residues during workup, a derivatisation procedure was developed, by which penicillins were converted to stable piperidine derivatives. Deuterated piperidine derivatives were synthesised for all relevant penicillins, enabling the use of isotope dilution for accurate quantification. Penicillin residues were derivatised in the crude extract with piperidine and isolated using solid-phase extraction. The penicillin piperidine derivatives were determined by LC-MS/MS. The method was validated at the current MRLs, which range from 25-300 A mu g kg(-1) in muscle and kidney to 4-30 A mu g kg(-1) in milk as well as at the target value of 100 A mu g kg(-1) chosen for animal feed, according to the EU requirements for a quantitative confirmatory method. Accuracy ranged from 94-113% (muscle), 83-111% (kidney) and 87-103% (milk) to 88-116% (animal feed). Intra-day precision (relative standard deviation (RSD)(r)) ranged from 5-13% (muscle, n = 18), 4-17% (kidney, n = 7) and 5-18% (milk, n = 7) to 11-32% (animal feed, n = 18). Inter-day precision (RSDRL, n = 18) ranged from 6-23% (muscle) to 11-36% (animal feed). From the results, it was concluded that the method was fit for purpose at the target MRLs in animal tissue and target levels for animal feed.
引用
收藏
页码:3027 / 3040
页数:14
相关论文
共 50 条
  • [41] Determination of sucralose by isotope-dilution liquid chromatography tandem mass spectrometry
    Heinz, Margot
    Schreiter, Pat
    Baumann, Markus
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 2008, 104 (04) : 166 - 170
  • [42] Analysis of acrylamide in coffee and cocoa by isotope dilution liquid chromatography-tandem mass spectrometry
    Aguas, Patricia C.
    Fitzhenry, Matthew J.
    Giannikopoulos, Georgina
    Varelis, Peter
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (08) : 1526 - 1531
  • [43] Evaluation of two liquid chromatography/tandem mass spectrometry platforms for quantification of monensin in animal feed and milk
    Dai, Susie Y.
    Herrman, Timothy J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (10) : 1431 - 1438
  • [44] Quantitative measurement of salivary testosterone in Korean adults by stable isotope-dilution liquid chromatography-electrospray-tandem mass spectrometry
    Lee, Sanghoo
    Kwon, Soonho
    Shin, Hye-Jin
    Park, Jimyeong
    Lim, Hwan-Sub
    Lee, Kyoung-Ryul
    Kim, Young-Jin
    BMB REPORTS, 2010, 43 (11) : 761 - 765
  • [45] Determination of colistin in animal tissues, egg, milk, and feed by ultra-high performance liquid chromatography-tandem mass spectrometry
    Fu, Qin
    Li, Xiaowei
    Zheng, Kangni
    Ke, Yuebin
    Wang, Yingyu
    Wang, Lina
    Yu, Fugen
    Xia, Xi
    FOOD CHEMISTRY, 2018, 248 : 166 - 172
  • [46] DETERMINATION OF UREA IN MILK BY LIQUID CHROMATOGRAPHY-ISOTOPE DILUTION MASS SPECTROMETRY
    Dai, Xinhua
    Zhao, Yingchen
    Li, Ming
    Fang, Xiang
    Li, Xiaomin
    Li, Hongmei
    Xu, Bei
    ANALYTICAL LETTERS, 2012, 45 (12) : 1557 - 1565
  • [47] Quantification of blood folate forms using stable-isotope dilution ultra performance liquid chromatography tandem mass spectrometry
    Kirsch, Susanne H.
    Herrmann, Wolfgang
    Obeid, Rima
    ADVANCES IN CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, : 91 - 94
  • [48] Determination of digoxin in human serum using stable isotope dilution liquid chromatography/electrospray ionization-tandem mass spectrometry
    Mitamura, Kuniko
    Horikawa, Aki
    Yamane, Yuko
    Ikeda, Yukari
    Fuji, Youichi
    Shimada, Kazutake
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2007, 30 (09) : 1653 - 1656
  • [49] QUANTIFICATION OF BLOOD FOLATE FORMS USING STABLE-ISOTOPE DILUTION ULTRA PERFORMANCE LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY
    Kirsch, S. H.
    Herrmann, W.
    Obeid, R.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S763 - S763
  • [50] Detection of allantoin in clinical samples using hydrophilic liquid chromatography with stable isotope dilution negative ion tandem mass spectrometry
    Turner, Rufus
    Stamp, Lisa K.
    Kettle, Anthony J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 891 : 85 - 89