Heat-up and start-up modeling of direct internal reforming solid oxide fuel cells

被引:27
作者
Colpan, C. Ozgur [1 ]
Hamdullahpur, Feridun [2 ]
Dincer, Ibrahim [3 ]
机构
[1] Carleton Univ, Dept Mech & Aerosp Engn, Ottawa, ON K1S 5B6, Canada
[2] Univ Waterloo, Mech & Mechatron Engn Dept, Waterloo, ON N2L 3G1, Canada
[3] Univ Ontario, Inst Technol, Fac Engn & Appl Sci, Oshawa, ON L1H 7L7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Solid oxide fuel cell; Internal reforming; Transient; Start-up; Thermomechanical; Failure; THERMAL-STRESS ANALYSIS; INTERMEDIATE-TEMPERATURE; PLANAR SOFC; SIMULATION; STACK;
D O I
10.1016/j.jpowsour.2009.12.021
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this paper, a transient heat transfer model to simulate the heat-up and start-up periods of co- and counter-flow direct internal reforming solid oxide fuel cells is developed and presented. In this comprehensive model, all the heat transfer mechanisms, i.e. conduction, convection, and radiation, and all the polarization nodes, i.e. ohmic, activation, and concentration, are considered. The heat transfer model is validated using the results of a benchmark test and two numerical studies obtained from the literature. After validating the model, the heat-up, start-up, and steady-state behaviors of the cell are investigated. In addition, the first principal thermal stresses are calculated to find the probability of failure of the cell during its operation. The results of the present model are in good agreement with the literature data. It is also shown for the given input data that counter-flow case yields a higher average current density and power density, but a lower electrical efficiency of the cell. For the temperature controlled heat-up and start-up strategy, the maximum probability of failure during the operation of the cell is found to be 0.068% and 0.078% for co- and counter-flow configurations, respectively. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3579 / 3589
页数:11
相关论文
共 24 条
[1]   3-DIMENSIONAL AND TIME-DEPENDENT SIMULATION OF A PLANAR SOLID OXIDE FUEL-CELL STACK [J].
ACHENBACH, E .
JOURNAL OF POWER SOURCES, 1994, 49 (1-3) :333-348
[2]  
ACHENBACH E, 1996, SOFC STACK MODELLING
[3]   Anode-supported intermediate-temperature direct internal reforming solid oxide fuel cell - II. Model-based dynamic performance and control [J].
Aguiar, P ;
Adjiman, CS ;
Brandon, NP .
JOURNAL OF POWER SOURCES, 2005, 147 (1-2) :136-147
[4]  
Bossel U.G., 1992, FINAL REPORT SOFC DA
[5]  
Braun R.J., 2002, OPTIMAL DESIGN OPERA
[6]   Polarization effects in electrolyte/electrode-supported solid oxide fuel cells [J].
Chan, SH ;
Xia, ZT .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2002, 32 (03) :339-347
[7]  
CHOUX Y, 2008, J ELECTROCHEMICAL SO, V155, pB650
[8]   A review on macro-level modeling of planar solid oxide fuel cells [J].
Colpan, C. Ozgur ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (04) :336-355
[9]   Thermodynamic modeling of direct internal reforming solid oxide fuel cells operating with syngas [J].
Colpan, C. Ozgur ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (07) :787-795
[10]   Thermal Modeling and Simulation of an Integrated Solid Oxide Fuel Cell and Charcoal Gasification System [J].
Colpan, C. Ozgur ;
Yoo, Yeong ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2009, 28 (03) :380-385