Experimental study on temperature and performance of an open-cathode PEMFC stack under thermal radiation environment

被引:28
作者
Zhang, Jikai [1 ,2 ]
Wang, Changjian [1 ,3 ]
Zhang, Aifeng [1 ,2 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Int Joint Res Ctr Hydrogen Safety, Hefei 230009, Peoples R China
[3] Minist Educ, Engn Res Ctr Safety Crit Ind Measurement & Contro, Hefei, Peoples R China
关键词
Open-cathode PEMFC; Thermal radiation; Performance degradation; Temperature distribution; Single -cell voltage uniformity; MEMBRANE FUEL-CELL; IN-SITU MEASUREMENT; RELATIVE-HUMIDITY; BREATHING PEMFC; FLOW CHANNEL; AIR; SYSTEM; OPTIMIZATION; DESIGN; ANODE;
D O I
10.1016/j.apenergy.2022.118646
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The open-cathode proton exchange membrane fuel cell stack is an air-cooled stack, and has the characteristics of small footprint and high power density because of its unique configuration, combining oxidizer and coolant via axial fan. Depending on the demands of the application, proton exchange membrane fuel cells inevitably operate in harsh environments, such as high pressure, low or high temperature, etc. In this study, the performance of a 10-cell open-cathode PEMFC stack under thermal radiation was evaluated. The variations in cathode air temperature and relative humidity, stack temperature, output power and single-cell voltage under three different radiant heat fluxes were obtained by changing the load current and cathode air flow rate. The experimental results show that, even if the thermal radiation is beneficial to improve the stack temperature, the stack performance is not improved in all tested cases. Conversely, the degradation of stack power and failure of the stack continuous operation can be observed, especially for higher radiant heat flux, higher load current and lower air velocity. For the highest radiant heat flux in current study, the temperature of the first single cell closest to the radiant heat source exceeds the maximum allowable operating temperature of 65 degrees C due to the insufficient capacity of air cooling and the heating effect of radiant heat source. The significant drop in the first single-cell voltage results in the rapid degradation of the overall performance of the stack, and finally the stack fails to run continuously.
引用
收藏
页数:13
相关论文
共 48 条
[1]   Performance evaluation of an open-cathode PEM fuel cell stack under ambient conditions: Case study of United Arab Emirates [J].
Al-Zeyoudi, Hend ;
Sasmito, Agus P. ;
Shamim, Tariq .
ENERGY CONVERSION AND MANAGEMENT, 2015, 105 :798-809
[2]   Temperature profiles of an air-cooled PEM fuel cell stack under active and passive cooling operation [J].
Atan, R. ;
Najmi, W. A. W. M. .
INTERNATIONAL SYMPOSIUM ON ROBOTICS AND INTELLIGENT SENSORS 2012 (IRIS 2012), 2012, 41 :1735-1742
[3]   An Open-Cathode Fuel Cell for Atmospheric Flight [J].
Atkinson, Robert W., III ;
Hazard, Matthew W. ;
Rodgers, Joseph A. ;
Stroman, Richard O. ;
Gould, Benjamin D. .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (02) :F46-F54
[4]   Development of cathode cooling fins with a multi-hole structure for open-cathode polymer electrolyte membrane fuel cells [J].
Baik, Kyung Don ;
Yang, Seong Ho .
APPLIED ENERGY, 2020, 279
[5]   A critical review on unmanned aerial vehicles power supply and energy management: Solutions, strategies, and prospects [J].
Boukoberine, Mohamed Nadir ;
Zhou, Zhibin ;
Benbouzid, Mohamed .
APPLIED ENERGY, 2019, 255
[6]   Development, manufacture and validation of an open cathode LT-PEMFC stack at HySA systems [J].
Bujlo, P. ;
Cornelius, C. ;
Barron, O. ;
Dyantyi, N. ;
Linkov, V. ;
Pasupathi, S. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2021, 46 (57) :29478-29487
[7]   Numerical investigation of the coupled water and thermal management in PEM fuel cell [J].
Cao, Tao-Feng ;
Lin, Hong ;
Chen, Li ;
He, Ya-Ling ;
Tao, Wen-Quan .
APPLIED ENERGY, 2013, 112 :1115-1125
[8]   Effects of ambient temperature and relative humidity on the performance of Nexa fuel cell [J].
Choi, Kap-Seung ;
Kim, Hyung-Man ;
Yoon, Hyung Chul ;
Forrest, Matthew E. ;
Erickson, Paul A. .
ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (12) :3505-3511
[9]   Performance of polymer electrolyte membrane fuel cell (PEMFC) stacks Part I. Evaluation and simulation of an air-breathing PEMFC stack [J].
Chu, D ;
Jiang, RZ .
JOURNAL OF POWER SOURCES, 1999, 83 (1-2) :128-133
[10]   Performance investigation of 2.4 kW PEM fuel cell stack in vehicles [J].
Corbo, P. ;
Migliardini, F. ;
Veneri, O. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (17) :4340-4349