Amperometric In Vitro Monitoring of Penetration through Skin Membrane

被引:5
作者
Gari, Hala [1 ]
Rembiesa, Jadwiga [1 ]
Masilionis, Ignas [1 ]
Vreva, Naida [1 ]
Svensson, Birgitta [2 ]
Sund, Torbjorn [2 ]
Hansson, Henri [3 ]
Moren, Anna Karin [3 ]
Sjoo, Malin [4 ]
Wahlgren, Marie [5 ]
Engblom, Johan [1 ]
Ruzgas, Tautgirdas [1 ]
机构
[1] Malmo Univ, Fac Hlth & Soc, Dept Biomed Sci, S-20506 Malmo, Sweden
[2] Bioglan AB, S-20213 Malmo, Sweden
[3] Galenica AB, S-20512 Malmo, Sweden
[4] Speximo AB, S-22381 Lund, Sweden
[5] Lund Univ, Ctr Chem, LTH, Div Food Technol, S-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
Penetration; Transdermal delivery; Amperometry; Quercetin; Hydrogen peroxide; Ascorbic acid; Skin membrane; TRANSDERMAL DRUG-DELIVERY; REAL-TIME; OXIDATIVE STRESS; HEAT-SEPARATION; ASCORBIC-ACID; DAMAGED SKIN; ELECTRODES; QUERCETIN; PERMEATION; ABSORPTION;
D O I
10.1002/elan.201400426
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to demonstrate that penetration of quercetin, hydrogen peroxide and ascorbic acid through skin membranes can be monitored amperometrically. Skin membrane was fixed on the top of chemically modified electrodes and penetration of the appropriate compound was registered as electrode current. The methodology allows the study of penetration from solution as well as from pharmaceutical creams. From real-time measurements of electrode current, fluxes and diffusion coefficients of mentioned compounds in skin membranes have been estimated.
引用
收藏
页码:111 / 117
页数:7
相关论文
共 31 条
  • [1] Real-time amperometric analysis of reactive oxygen and nitrogen species released by single immunostimulated macrophages
    Amatore, Christian
    Arbault, Stephane
    Bouton, Cecile
    Drapier, Jean-Claude
    Ghandour, Hala
    Koh, Alaric C. W.
    [J]. CHEMBIOCHEM, 2008, 9 (09) : 1472 - 1480
  • [2] MONITORING AN OXIDATIVE STRESS MECHANISM AT A SINGLE HUMAN FIBROBLAST
    ARBAULT, S
    PANTANO, P
    JANKOWSKI, JA
    VUILLAUME, M
    AMATORE, C
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (19) : 3382 - 3390
  • [3] Oxidative stress in cancer prone xeroderma pigmentosum fibroblasts. Real-time and single cell monitoring of superoxide and nitric oxide production with microelectrodes
    Arbault, S
    Sojic, N
    Bruce, D
    Amatore, C
    Sarasin, A
    Vuillaume, M
    [J]. CARCINOGENESIS, 2004, 25 (04) : 509 - 515
  • [4] Epidermal tattoo potentiometric sodium sensors with wireless signal transduction for continuous non-invasive sweat monitoring
    Bandodkar, Amay J.
    Molinnus, Denise
    Mirza, Omar
    Guinovart, Tomas
    Windmiller, Joshua R.
    Valdes-Ramirez, Gabriela
    Andrade, Francisco J.
    Schoening, Michael J.
    Wang, Joseph
    [J]. BIOSENSORS & BIOELECTRONICS, 2014, 54 : 603 - 609
  • [5] Tattoo-based potentiometric ion-selective sensors for epidermal pH monitoring
    Bandodkar, Amay J.
    Hung, Vinci W. S.
    Jia, Wenzhao
    Valdes-Ramirez, Gabriela
    Windmiller, Joshua R.
    Martinez, Alexandra G.
    Ramirez, Julian
    Chan, Garrett
    Kerman, Kagan
    Wang, Joseph
    [J]. ANALYST, 2013, 138 (01) : 123 - 128
  • [6] Skin Membrane Electrical Impedance Properties under the Influence of a Varying Water Gradient
    Bjorklund, Sebastian
    Ruzgas, Tautgirdas
    Nowacka, Agnieszka
    Dahi, Ihab
    Topgaard, Daniel
    Sparr, Emma
    Engblom, Johan
    [J]. BIOPHYSICAL JOURNAL, 2013, 104 (12) : 2639 - 2650
  • [7] In vitro evaluation of quercetin cutaneous absorption from topical formulations and its functional stability by antioxidant activity
    Casagrande, Rubia
    Georgetti, Sandra R.
    Verri, Waldiceu A., Jr.
    Borin, Maria F.
    Lopez, Renata F. V.
    Fonseca, Maria J. V.
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2007, 328 (02) : 183 - 190
  • [8] Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes
    de Mattos, IL
    Gorton, L
    Ruzgas, T
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) : 193 - 200
  • [9] INVITRO SKIN PERMEATION TECHNIQUES
    FRIEND, DR
    [J]. JOURNAL OF CONTROLLED RELEASE, 1992, 18 (03) : 235 - 248
  • [10] Microneedle Electrodes Toward an Amperometric GlucoseSensing Smart Patch
    Invernale, Michael A.
    Tang, Benjamin C.
    York, Royce L.
    Le, Long
    Hou, David Yupeng
    Anderson, Daniel G.
    [J]. ADVANCED HEALTHCARE MATERIALS, 2014, 3 (03) : 338 - 342