Effect of modified Blalock-Taussig shunt anastomosis angle and pulmonary artery diameter on pulmonary flow

被引:21
作者
Arnaz, Ahmet [1 ]
Piskin, Senol [2 ,3 ]
Oguz, Gokece Nur [2 ]
Yalcinbas, Yusuf [4 ]
Pekkan, Kerem [2 ]
Sarioglu, Tayyar [1 ]
机构
[1] Acibadem Mehmet Ali Aydinlar Univ, Fac Med, Dept Cardiovasc Surg, Istanbul, Turkey
[2] Koc Univ, Dept Mech Engn, Istanbul, Turkey
[3] Univ Texas San Antonio, Dept Mech Engn, San Antonio, TX USA
[4] Acibadem Bakirkoy Hosp, Dept Cardiovasc Surg, Istanbul, Turkey
基金
欧洲研究理事会;
关键词
modified Blalock-Taussig shunt; shunt stenosis; computational fluid dynamics; hemodynamic; simulations; SHEAR-STRESS; CIRCLE; SIZE;
D O I
10.14744/AnatolJCardiol.2018.54810
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed to identify the best graft-to-pulmonary artery (PA) anastomosis angle measuring pulmonary blood flow, wall shear stress (WSS), and shunt flow. Methods: A tetralogy of Fallot with pulmonary atresia computer model was used to study three different modified Blalock-Taussig shunt (mBTS) anastomosis angle configurations with three different PA diameter configurations. Velocity and WSS were analyzed, and the flow rates at the right PA (RPA) and left PA (LPA) were calculated. Results: A 4-mm and 8-mm diameter of RPA and LPA, respectively with vertical shunt angle produces the highest total flow. In the RPA larger diameter than the LPA configutations, the left-leaning shunt produces the lowest total PA flow whereas in the LPA larger diameter than the RPA configuratios, the right-leaning shunt produces the lowest total PA flow. Therefore, the shunt anastomosis should not be leaned through the narrow side of PA to reach best flow. As the flow inside the shunt increased, WSS also increased due to enhanced velocity gradients. Conclusion: The anastomosis angle between the conduit and PA affects the flow to PA. Vertical anastomosis configurations increase the total PA flow; thus, these configurations are preferable than the leaned configurations.
引用
收藏
页码:2 / 8
页数:7
相关论文
共 19 条
[1]   A tensor-based measure for estimating blood damage [J].
Arora, D ;
Behr, M ;
Pasquali, M .
ARTIFICIAL ORGANS, 2004, 28 (11) :1002-1015
[2]   THE SURGICAL TREATMENT OF MALFORMATIONS OF THE HEART - IN WHICH THERE IS PULMONARY STENOSIS OR PULMONARY ATRESIA [J].
BLALOCK, A ;
TAUSSIG, HB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1945, 128 (03) :189-202
[3]  
Chaudhari M, 2004, Eur J Echocardiogr, V5, P111, DOI 10.1016/S1525-2167(03)00052-0
[4]   The role of shear stress in the pathogenesis of atherosclerosis [J].
Cunningham, KS ;
Gotlieb, AI .
LABORATORY INVESTIGATION, 2005, 85 (01) :9-23
[5]   Cannulation Strategy for Aortic Arch Reconstruction Using Deep Hypothermic Circulatory Arrest [J].
De Zelicourt, Diane ;
Jung, Philsub ;
Horner, Marc ;
Pekkan, Kerem ;
Kanter, Kirk R. ;
Yoganathan, Ajit P. .
ANNALS OF THORACIC SURGERY, 2012, 94 (02) :614-621
[6]  
DELEVAL MR, 1981, J THORAC CARDIOV SUR, V81, P112
[7]  
Dur O, 2011, CARDIOVASC ENG TECHN, V2, P35, DOI DOI 10.1007/S13239-010-0029-Z
[8]  
Erek E, 2007, TURKISH J THORAC CAR, V15, P29
[9]  
Fitts Michelle K, 2014, Open Urol Nephrol J, V7, P33
[10]   Risk factors for acute shunt blockage in children after modified Blalock-Taussig shunt operations [J].
Gedicke, Malenke ;
Morgan, Gareth ;
Parry, Andrew ;
Martin, Rob ;
Tulloh, Rob .
HEART AND VESSELS, 2010, 25 (05) :405-409