Conversion of steam power plant into cogeneration unit-Case study

被引:7
|
作者
Panowski, Marcin [1 ]
Zarzycki, Robert [1 ]
Kobylecki, Rafal [1 ]
机构
[1] Czestochowa Tech Univ, Dept Adv Energy Technol, JH Dabrowskiego 73, PL-42201 Czestochowa, Poland
关键词
Cogeneration; Waste heat utilization; Absorption heat pumps; ORGANIC RANKINE-CYCLE; ABSORPTION HEAT-PUMP; WASTE HEAT; THERMODYNAMIC PERFORMANCE; LOW-TEMPERATURE; SYSTEM; RECOVERY;
D O I
10.1016/j.energy.2021.120872
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of possible solutions leading to the increase of steam power plant thermal efficiency is its conversion into a cogeneration unit. However, it requires the heat recipient to be on-site and, if so, it may be done by implementation of absorption heat pump (AHP) technology with low temperature waste heat recovery and utilization. The paper presents results of an analysis of benefits resulting from implementation of absorption heat pump into the steam power plant for recovery of low temperature waste heat, due to additional demand for heat delivery to dedicated recipient (DHR). The demand for heat along the whole year was assumed and the calculations were performed for two cases. In the first case, which was called the reference case, the heat was produced by dedicated heat exchanger (DHX) fed with steam taken from the pipeline between the medium and low-pressure turbine sections (MPLPP). In the second case, absorption heat pump (AHP) as the main unit for heat production and recovery was assumed. However, due to insufficient heat production in some conditions, peak heat exchanger (PHX) placed directly behind the heat pump was considered. Both heat pump and pick heat exchanger were fed with steam taken from MPLPP, however, due to the AHP requirements the stem was mixed with hot water taken from hot water tank to achieve the steam saturation state. Results of calculations performed show that implementation of a heat recuperation by absorption heat pump implemented to conventional steam power plant increases the overall efficiency of cogeneration system, but at the same time it causes the electricity production to decrease. Moreover, the production of heat by absorption heat pump has lower impact on the electricity generation compared to generation of heat by conventional heat exchanger. If reference power plant without heat production is considered, due to the heat pump implementation the electricity production decreases of about 1.32% for heat production with dedicated heat exchanger, and of about 0.89% for absorption heat pump with peek heat exchanger respectively. It means that, owing to implementation of AHP instead of DHX with the same heat production, the power plant may generate more than 0.4% of total electricity produced. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] STEAM POWER UNIT WITH A PEAK LOAD GAS-TURBINE PLANT
    KIRILLOV, II
    POLISHCHUK, VL
    ARSENEV, LV
    THERMAL ENGINEERING, 1974, 21 (03) : 15 - 18
  • [32] Software system "DIORES" for the operation diagnosis of a steam power plant unit
    Savic, Branislav M.
    Jovanovic, Radisa Z.
    ENERGY, 2011, 36 (02) : 1187 - 1195
  • [33] Study on Power Conversion Unit of HTGR and VHTR
    Qu X.
    Yang X.
    Wang J.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (11): : 2148 - 2156
  • [34] Cogeneration Waste Heat Conversion to Electric Power
    Pipa, Marek
    Kubica, Juraj
    Janicek, Frantisek
    11TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2010, PROCEEDINGS, 2010, : 229 - 232
  • [35] VALIDATION OF ADVANCED STEAM TURBINE TECHNOLOGY - A CASE STUDY OF AN ULTRA SUPER CRITICAL STEAM TURBINE POWER PLANT
    Quinkertz, Rainer
    Thiemann, Thomas
    Gierse, Kai
    PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 7, PTS A-C, 2012, : 2381 - 2391
  • [36] Simulation of a Multi-Functional Energy System for cogeneration of steam, power and hydrogen in a coke making plant
    Farzaneh, Hooman
    Ghalee, Iman
    Dashti, Mehrnoosh
    3RD INTERNATIONAL CONFERENCE ON SUSTAINABLE FUTURE FOR HUMAN SECURITY, SUSTAIN 2012, 2013, 17 : 711 - 718
  • [37] Guilan combined power plant in Iran: As case study for feasibility investigation of converting the combined power plant into water and power unit
    Amiralipour, M.
    Kouhikamali, R.
    ENERGY, 2020, 201 (201)
  • [38] Performance study of cogeneration system based on solar power tower plant
    Li X.
    Wang Z.
    Yang M.
    Guo M.
    Yu Q.
    Hua Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (06): : 203 - 210
  • [39] Development and Implementation of Automatic Conversion of Steam-Gas Power Unit from Compound Cycle Mode to Steam-Power Mode Without Shutdown of the Unit
    Anisimov A.G.
    Mysak I.S.
    Klub M.V.
    Sargsyan K.B.
    Eritsyan S.K.
    Petrosyan G.S.
    Avtandilyan A.V.
    Gevorgyan A.R.
    Power Technology and Engineering, 2018, 51 (05) : 568 - 573
  • [40] Failure in power plant system related to mitigations and economic analysis; A study case from steam power plant in Suralaya, Indonesia
    Nugraha, Ariyana Dwiputra
    Harianto
    Muflikhun, Muhammad Akhsin
    RESULTS IN ENGINEERING, 2023, 17