Conversion of steam power plant into cogeneration unit-Case study

被引:7
|
作者
Panowski, Marcin [1 ]
Zarzycki, Robert [1 ]
Kobylecki, Rafal [1 ]
机构
[1] Czestochowa Tech Univ, Dept Adv Energy Technol, JH Dabrowskiego 73, PL-42201 Czestochowa, Poland
关键词
Cogeneration; Waste heat utilization; Absorption heat pumps; ORGANIC RANKINE-CYCLE; ABSORPTION HEAT-PUMP; WASTE HEAT; THERMODYNAMIC PERFORMANCE; LOW-TEMPERATURE; SYSTEM; RECOVERY;
D O I
10.1016/j.energy.2021.120872
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of possible solutions leading to the increase of steam power plant thermal efficiency is its conversion into a cogeneration unit. However, it requires the heat recipient to be on-site and, if so, it may be done by implementation of absorption heat pump (AHP) technology with low temperature waste heat recovery and utilization. The paper presents results of an analysis of benefits resulting from implementation of absorption heat pump into the steam power plant for recovery of low temperature waste heat, due to additional demand for heat delivery to dedicated recipient (DHR). The demand for heat along the whole year was assumed and the calculations were performed for two cases. In the first case, which was called the reference case, the heat was produced by dedicated heat exchanger (DHX) fed with steam taken from the pipeline between the medium and low-pressure turbine sections (MPLPP). In the second case, absorption heat pump (AHP) as the main unit for heat production and recovery was assumed. However, due to insufficient heat production in some conditions, peak heat exchanger (PHX) placed directly behind the heat pump was considered. Both heat pump and pick heat exchanger were fed with steam taken from MPLPP, however, due to the AHP requirements the stem was mixed with hot water taken from hot water tank to achieve the steam saturation state. Results of calculations performed show that implementation of a heat recuperation by absorption heat pump implemented to conventional steam power plant increases the overall efficiency of cogeneration system, but at the same time it causes the electricity production to decrease. Moreover, the production of heat by absorption heat pump has lower impact on the electricity generation compared to generation of heat by conventional heat exchanger. If reference power plant without heat production is considered, due to the heat pump implementation the electricity production decreases of about 1.32% for heat production with dedicated heat exchanger, and of about 0.89% for absorption heat pump with peek heat exchanger respectively. It means that, owing to implementation of AHP instead of DHX with the same heat production, the power plant may generate more than 0.4% of total electricity produced. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [22] Exergy analysis of steam power and cogeneration plants
    El-Dib, A.F.
    Journal of Engineering and Applied Science, 1998, 45 (05): : 791 - 809
  • [23] Performance analysis of the power conversion unit of a solar chimney power plant
    Fluri, T. P.
    Von Backstrom, T. W.
    SOLAR ENERGY, 2008, 82 (11) : 999 - 1008
  • [24] Studies on Steam Absorption Chillers Performance at a Cogeneration Plant
    Majid, Mohd Amin Abd
    Sulaiman, Shaharin Anwar
    Fujii, Tatsuo
    Naono
    ICPER 2014 - 4TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY, 2014, 13
  • [25] Dry steam cycle application for excess steam utilization: Kamojang geothermal power plant case study
    Prananto, Lukman Adi
    Juangsa, Firman Bagja
    Iqbal, Riza Mochamad
    Aziz, Muhammad
    Soelaiman, Tubagus Ahmad Fauzi
    RENEWABLE ENERGY, 2018, 117 : 157 - 165
  • [26] Steam generation unit in a simple version of biomass based small cogeneration unit
    Sornek, Krzysztof
    Filipowicz, Mariusz
    Szubel, Mateusz
    Bozek, Estera
    Izdebski, Krzysztof
    101 EUROTHERM SEMINAR - TRANSPORT PHENOMENA IN MULTIPHASE SYSTEMS, 2014, 18
  • [27] INTEGRATION OF STEAM POWER PLANT WITH SITE UTILITY SYSTEM USING A NEW COGENERATION TARGETING METHOD
    KhoshgoftarManesh, Mohammad Hasan
    Abadi, Sajad Khamis
    Ghalami, Hooman
    Amidpour, Majid
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 233 - 243
  • [28] BIOMASS-FIRED STEAM POWER COGENERATION SYSTEM - A THEORETICAL-STUDY
    PRASAD, SB
    ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (01) : 65 - 77
  • [29] Process steam generation based on a stroke engine cogeneration unit
    Pospisil, J.
    Lisy, M.
    Fiedler, J.
    Chroboczek, L.
    PROCEEDINGS OF THE 6TH IASME/WSEAS INTERNATIONAL CONFERENCE ON HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT (HTE'08), PTS I AND II: NEW ASPECTS OF HEAT TRANSFER, THERMAL ENGINEERING AND ENVIRONMENT, 2008, : 111 - +
  • [30] An analysis of integration of a power plant with a lignite superheated steam drying unit
    Jaszczur, Marek
    Dudek, Michal
    Rosen, Marc A.
    Kolenda, Zygmunt
    JOURNAL OF CLEANER PRODUCTION, 2020, 243