Conversion of steam power plant into cogeneration unit-Case study

被引:7
|
作者
Panowski, Marcin [1 ]
Zarzycki, Robert [1 ]
Kobylecki, Rafal [1 ]
机构
[1] Czestochowa Tech Univ, Dept Adv Energy Technol, JH Dabrowskiego 73, PL-42201 Czestochowa, Poland
关键词
Cogeneration; Waste heat utilization; Absorption heat pumps; ORGANIC RANKINE-CYCLE; ABSORPTION HEAT-PUMP; WASTE HEAT; THERMODYNAMIC PERFORMANCE; LOW-TEMPERATURE; SYSTEM; RECOVERY;
D O I
10.1016/j.energy.2021.120872
中图分类号
O414.1 [热力学];
学科分类号
摘要
One of possible solutions leading to the increase of steam power plant thermal efficiency is its conversion into a cogeneration unit. However, it requires the heat recipient to be on-site and, if so, it may be done by implementation of absorption heat pump (AHP) technology with low temperature waste heat recovery and utilization. The paper presents results of an analysis of benefits resulting from implementation of absorption heat pump into the steam power plant for recovery of low temperature waste heat, due to additional demand for heat delivery to dedicated recipient (DHR). The demand for heat along the whole year was assumed and the calculations were performed for two cases. In the first case, which was called the reference case, the heat was produced by dedicated heat exchanger (DHX) fed with steam taken from the pipeline between the medium and low-pressure turbine sections (MPLPP). In the second case, absorption heat pump (AHP) as the main unit for heat production and recovery was assumed. However, due to insufficient heat production in some conditions, peak heat exchanger (PHX) placed directly behind the heat pump was considered. Both heat pump and pick heat exchanger were fed with steam taken from MPLPP, however, due to the AHP requirements the stem was mixed with hot water taken from hot water tank to achieve the steam saturation state. Results of calculations performed show that implementation of a heat recuperation by absorption heat pump implemented to conventional steam power plant increases the overall efficiency of cogeneration system, but at the same time it causes the electricity production to decrease. Moreover, the production of heat by absorption heat pump has lower impact on the electricity generation compared to generation of heat by conventional heat exchanger. If reference power plant without heat production is considered, due to the heat pump implementation the electricity production decreases of about 1.32% for heat production with dedicated heat exchanger, and of about 0.89% for absorption heat pump with peek heat exchanger respectively. It means that, owing to implementation of AHP instead of DHX with the same heat production, the power plant may generate more than 0.4% of total electricity produced. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Evaluation of Redundancy for Power Generating Unit in a Cogeneration Power Plant
    Reshid, Meseret Nasir
    Abd Majid, Mohd Amin
    Muhammad, Masdi
    ICPER 2014 - 4TH INTERNATIONAL CONFERENCE ON PRODUCTION, ENERGY AND RELIABILITY, 2014, 13
  • [2] Power-Augmented Steam Power Plant in a Cogeneration Cement Factory
    Varma, G. V. Pradeep
    Srinivas, T.
    JOURNAL OF ENERGY ENGINEERING, 2017, 143 (01)
  • [3] PERFORMANCE EVALUATION OF A GAS AND STEAM TURBINE BASED COGENERATION PLANT: A CASE STUDY
    Gogoi, Tapan Kr.
    Gautam, Uddipta
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2019, VOL 1, 2020,
  • [4] THE EFFECT OF STEAM TEMPERATURE ON THE ECONOMICS OF A COGENERATION POWER-PLANT
    HAM, RW
    DOUGLAS, PL
    FULFORD, G
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1988, 66 (06): : 987 - 994
  • [5] COGENERATION OF STEAM AND ELECTRIC-POWER (THE FACTORY SUGAR PRODUCTION COGENERATION CASE)
    UPADHIAYA, UC
    INTERNATIONAL SUGAR JOURNAL, 1992, 94 (1117): : 2 - 10
  • [6] Impact of Chemical Cleaning on Furnace Exit Gas Temperature of Power Plant:Case Study Steam Power Plant Unit 1
    Silalahi, Netha A. M.
    Widanarko, Baskoro
    Jaganathan, Saravana Kumar
    2021 11TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2021), 2021, : 182 - 188
  • [7] Energy and exergy analysis of dry-steam geothermal power plant: Case study in kamojang geothermal power plant unit 2
    Setyawan, Nova Dany
    Pambudi, Nugroho Agung
    Utomo, Frandhoni
    Saputro, Herman
    Adiprana, Reza
    Saw, Lip Huat
    Gurturk, Mert
    Rudiyanto, Bayu
    3RD ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2018), 2018, 197
  • [8] Effect of steam-injected gas turbines on the unit sizing of a cogeneration plant
    Ito, K
    Yokoyama, R
    Matsumoto, Y
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 1997, 119 (01): : 131 - 136
  • [9] Calculation of the power loss coefficient of steam turbine as a part of the cogeneration plant
    Urosevic, Dragan
    Gvozdenac, Dusan
    Grkovic, Vojin
    ENERGY, 2013, 59 : 642 - 651
  • [10] THE INCREASE OF ENERGY EFFICIENCY THROUGH THE CONVERSION OF A THERMAL POWER PLANT INTO A COGENERATION PLANT
    Blaga, Petre
    Necula, Horia
    Ionescu, Constantin
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2010, 72 (01): : 53 - 64