In vivo corrosion and corrosion protection of magnesium alloy LAE442

被引:374
作者
Witte, F. [1 ]
Fischer, J. [1 ]
Nellesen, J. [2 ]
Vogt, C. [3 ]
Vogt, J. [4 ]
Donath, T. [5 ]
Beckmann, F. [5 ]
机构
[1] Hannover Med Sch, Lab Biomech & Biomat, D-30625 Hannover, Germany
[2] Tech Univ Dortmund, Dept Mech Engn, Chair Qual Management, D-44227 Dortmund, Germany
[3] Leibniz Univ Hannover, Inst Inorgan Chem, D-30167 Hannover, Germany
[4] Univ Jena, Inst Phys, Inst Expt Phys 2, Fac Phys & Earth Sci, D-04102 Leipzig, Germany
[5] GKSS Forschungszentrum Geesthacht GmbH, D-21502 Geesthacht, Germany
关键词
Biodegradation; Magnesium; Corrosion; Micro-tomography; Imaging; BONE IMPLANT APPLICATION; COMPUTED MICROTOMOGRAPHY; MU-CT; SCAFFOLDS; BEHAVIOR; VITRO; METAL; MODEL; SR;
D O I
10.1016/j.actbio.2009.10.012
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of this study was to investigate whether the extruded magnesium alloy LAE442 reacts in vivo with an appropriate host response and to investigate how an additional magnesium fluoride (MgF2) coating influences the in vivo corrosion rate. Forty cylinders were machined from extruded LAE442 and 20 of these were coated additionally with MgF2 and implanted into the medial femur condyle of adult rabbits. Synchrotron-radiation-based X-ray computed micro-tomography (SR mu CT) was used to quantitatively analyse corrosion non-destructively in vivo and comparisons were made to magnesium degradation rates based on area measurements of the remaining metal on uncalcified sections. Blood concentrations of the alloying elements were measured below toxicological limits. The MgF2 layer was no longer detected after 4 weeks of implantation by particle-induced gamma emission, and the MgF2 coating reduced the blood content of alloying elements during the first 6 weeks of implantation with no elevated fluoride concentration in the adjacent bone. Histopathological examinations of liver showed in 9 out of 40 cases minimal infiltrations of heterophil granulocytes of unknown origin (5 LAE442, 4 LAE442 + MgF2). The kidneys were mainly regular in structure. The synovial tissue showed a granular cell infiltration as a temporary observation in the LAE442 + MgF2 group after 2 weeks. No subcutaneous gas cavities were observed clinically and on postoperative X-rays in all animals. All specimens were scanned by SR mu CT at 2, 4, 6 and 12 weeks postoperatively before uncalcified sections were performed. All magnesium implants have been observed in direct bone contact and without a fibrous capsule. Localized pitting corrosion occurred in coated and uncoated magnesium implants. This study shows that the extruded magnesium alloy LAE442 provides low corrosion rates and reacts in vivo with an acceptable host response. The in vivo corrosion rate can be further reduced by additional MgF2 coating. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1792 / 1799
页数:8
相关论文
共 31 条
[1]  
*ASTM, G46942005 ASTM
[2]  
Avedesian M.M., 1999, MAGNESIUM MAGNESIUM
[3]  
Beck A., 1939, MAGNESIUM SEINE LEGI
[4]  
Bernhardt R, 2004, Eur Cell Mater, V7, P42
[5]   Osteoconductive modifications of Ti-implants in a goat defect model:: characterization of bone growth with SR μCT and histology [J].
Bernhardt, R ;
van den Dolder, J ;
Bierbaum, S ;
Beutner, R ;
Scharnweber, D ;
Jansen, J ;
Beckmann, F ;
Worch, H .
BIOMATERIALS, 2005, 26 (16) :3009-3019
[6]   3D COMPUTED X-RAY TOMOGRAPHY OF HUMAN CANCELLOUS BONE AT 8 MU-M SPATIAL AND 10(-4) ENERGY RESOLUTION [J].
BONSE, U ;
BUSCH, F ;
GUNNEWIG, O ;
BECKMANN, F ;
PAHL, R ;
DELLING, G ;
HAHN, M ;
GRAEFF, W .
BONE AND MINERAL, 1994, 25 (01) :25-38
[7]   X-ray computed microtomography (mu CT) using synchrotron radiation (SR) [J].
Bonse, U ;
Busch, F .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1996, 65 (1-2) :133-169
[8]   ACUTE MAMMALIAN TOXICITY OF RARE EARTH NITRATES AND OXIDES [J].
BRUCE, DW ;
HIETBRINK, BE ;
DUBOIS, KP .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1963, 5 (06) :750-&
[9]  
DONATH T, 2004, P SPIE INT SOC OPT E, P775
[10]   Determination of concentration gradients in bone tissue generated by a biologically degradable magnesium implant [J].
Gruhl, Susan ;
Witte, Frank ;
Vogt, Juergen ;
Vogt, Carla .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (02) :181-188