Far and near visual acuity with multifocal intraocular lenses in an optomechanical eye model with imaging capability

被引:12
作者
Gobbi, Pier Giorgio
Fasce, Francesco
Bozza, Stefano
Calori, Giliola
Brancato, Rosario
机构
[1] Univ Milan, Hosp San Raffaele, Dept Ophthalmol, I-20132 Milan, Italy
[2] Univ Milan, Hosp San Raffaele, Clin Res Off, I-20132 Milan, Italy
关键词
D O I
10.1016/j.jcrs.2007.01.028
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the quantitative and qualitative visual performances of different multifocal intraocular lenses (IOLs) in an experimental model of the human eye. SETTING: University Hospital San Raffaele, Milan, Italy. METHODS: Five multifocal IOLs and 1 monofocal IOL were implanted in an optomechanical eye model with imaging capability. The comparative optical characterization of the imaging performance included aberrometry, simulated visual acuity testing at variable contrast for far and near distance, glare tests, and image records of optotype charts. RESULTS: The maximum recorded far visual acuity for the monofocal IOL was between 20/12.5 and 20/16; the multifocal IOLs decreased visual acuity by 1 to 2 lines. The difference tended to increase at reduced contrast. Full-contrast near visual acuity with multifocal IOLs ranged between 20/63 and 20/25; the near distance performance of the monofocal IOL without an additional correcting lens was worse by 1 to 3 lines of acuity with large pupils but was comparable with small pupils. Multifocal IOLs of different designs showed marked differences as a function of contrast, which tended to balance between far and near behaviors. CONCLUSIONS: Multifocal IOLs of different optical designs were well characterized and distinguished by simulated contrast acuity testing in an experimental eye model, allowing quantitative comparison. Their overall visual performance, averaged over contrast and distance, was not superior to the performance of a monofocal IOL without an additional correcting lens.
引用
收藏
页码:1082 / 1094
页数:13
相关论文
共 64 条
[41]   Effect of intraocular lens implantation on visual acuity, contrast sensitivity, and depth of focus [J].
Nio, YK ;
Jansonius, NM ;
Geraghty, E ;
Norrby, S ;
Kooijman, AC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (11) :2073-2081
[42]   Accommodation amplitude after lens refilling with injectable silicone by sealing the capsule with a plug in primates [J].
Nishi, O ;
Nishi, K .
ARCHIVES OF OPHTHALMOLOGY, 1998, 116 (10) :1358-1361
[43]   Controlling the capsular shape in lens refilling [J].
Nishi, O ;
Nishi, K ;
Mano, C ;
Ichihara, M ;
Honda, T .
ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (04) :507-510
[44]   CONTRAST SENSITIVITY IN PATIENTS WITH A NEW TYPE OF MULTIFOCAL INTRAOCULAR-LENS [J].
OLSEN, T ;
CORYDON, L .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (01) :42-46
[45]   PHACO-ERSATZ - CATARACT-SURGERY DESIGNED TO PRESERVE ACCOMMODATION [J].
PAREL, JM ;
GELENDER, H ;
TREFERS, WF ;
NORTON, EWD .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1986, 224 (02) :165-173
[46]   Appearance of images through a multifocal intraocular lens [J].
Peli, E ;
Lang, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (02) :302-309
[47]   PROSPECTIVELY RANDOMIZED TRIAL COMPARING THE PSEUDOACCOMMODATION OF THE AMO-ARRAY MULTIFOCAL LENS AND A MONOFOCAL LENS [J].
PERCIVAL, SPB ;
SETTY, SS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (01) :26-31
[48]   Halo size under distance and near conditions in refractive multifocal intraocular lenses [J].
Pieh, S ;
Lackner, B ;
Hanselmayer, G ;
Zöhrer, R ;
Sticker, M ;
Weghaupt, H ;
Fercher, A ;
Skorpik, C .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (07) :816-821
[49]   Contrast sensitivity and glare disability with diffractive and refractive multifocal intraocular lenses [J].
Pieh, S ;
Weghaupt, H ;
Skorpik, C .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05) :659-662
[50]  
Pieh S, 2002, ARCH OPHTHALMOL-CHIC, V120, P23