Predictive value for paravalvular regurgitation of 3-dimensional anatomic aortic annulus shape assessed by multidetector computed tomography post-transcatheter aortic valve replacement

被引:7
作者
Ciobotaru, Vlad [1 ]
Maupas, Eric [1 ]
Durrleman, Nicolas [1 ]
Boulenc, Jean-Marc [1 ]
Borton, Augustin [1 ]
Pujadas-Berthault, Penelope [1 ]
Rioux, Philippe [1 ]
Maubon, Antoine [2 ]
机构
[1] Hop Prive Franciscaines, Chirurg Cardiothorac & Vasc, Serv Cardiol, 9 Impasse Jean Bouin, Nimes, France
[2] Hop Prive Franciscaines, Serv Radiol, Nimes, France
关键词
trans-catheter aortic valve replacement; aortic stenosis; aortic annulus; 3D MDCT; paravalvular aortic regurgitation; IMPLANTATION; OUTCOMES; IMPACT;
D O I
10.1093/ehjci/jev128
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Paravalvular regurgitation (PAR) remains a serious complication after trans-catheter aortic valve replacement (TAVR). Multidetector computed tomography (MDCT)-based measurements of the aortic basal virtual ring (BVR) are considered the gold standard for trans-catheter heart valve (THV) sizing. However, the real anatomic aortic annulus is a 3-dimensional structure. To compare measurement of 3D-anatomic annulus with BVR and secondly to assess independent predictive parameters that may impact on PAR>mild post-TAVR (PAR+). Methods and results MDCT was performed in 92 patients before and after balloon or self-expandableTAVR. 3D-AA shape was obtained point by point following the semilunar attachment of aortic cusps (Osirix-MD 2.8.2). 3D-oversizing index (nominal THV area/3D-AA area 2 1) x 100 was calculated as well as 2D-oversizing index using BVR area instead of 3D-AA area. PAR was quantified by planimetry of vena-contracta in transthoracic echocardiography short-axis view. Valvular calcium volume and annulus calcium area were measured using Hounsfield-intensity detection. ROC curves and logistic regression for PAR(+) were performed. BVR area overall underestimated 3D-AA area by 19 +/- 9% (P < 0.001), significantly more in PAR(+) (26 +/- 7%) vs. PAR(2) (17 +/- 9%, P < 0.001). 3D-oversizing index had greater predictive value for PAR < mild (area under the curve, AUC = 0.88) with 88% sensibility (Se) and 82% specificity (Sp) than 2D-oversizing index (AUC = 0.68) with 84% Se, but only 41% Sp (P < 0.0001). Also, valvular calcium volume and annulus calcium area were less predictors for PAR > mild (AUC = 0.68, respectively, AUC = 0.75, P = 0.002). In a multivariate analysis, only 3D-oversizing index showed an independent value for PAR. mild (OR = 18.6, P < 0.001). Conclusion Basal ring CT measurement significantly underestimated the real 3D-anatomic aortic annulus area. This may impact on THV sizing and PAR incidence. 3D-oversizing index is the most predictive factor for PAR > mild.
引用
收藏
页码:85 / 95
页数:11
相关论文
共 19 条
[1]   Incidence, Predictors, and Outcomes of Aortic Regurgitation After Transcatheter Aortic Valve Replacement Meta-Analysis and Systematic Review of Literature [J].
Athappan, Ganesh ;
Patvardhan, Eshan ;
Tuzcu, E. Murat ;
Svensson, Lars Georg ;
Lemos, Pedro A. ;
Fraccaro, Chiara ;
Tarantini, Giuseppe ;
Sinning, Jan-Malte ;
Nickenig, Georg ;
Capodanno, Davide ;
Tamburino, Corrado ;
Latib, Azeem ;
Colombo, Antonio ;
Kapadia, Samir R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (15) :1585-1595
[2]   Anatomical and Procedural Features Associated With Aortic Root Rupture During Balloon-Expandable Transcatheter Aortic Valve Replacement [J].
Barbanti, Marco ;
Yang, Tae-Hyun ;
Cabau, Josep Rodes ;
Tamburino, Corrado ;
Wood, David A. ;
Jilaihawi, Hasan ;
Blanke, Phillip ;
Makkar, Raj R. ;
Latib, Azeem ;
Colombo, Antonio ;
Tarantini, Giuseppe ;
Raju, Rekha ;
Binder, Ronald K. ;
Nguyen, Giang ;
Freeman, Melanie ;
Ribeiro, Henrique B. ;
Kapadia, Samir ;
Min, James ;
Feuchtner, Gudrun ;
Gurtvich, Ronen ;
Alqoofi, Faisal ;
Pelletier, Marc ;
Ussia, Gian Paolo ;
Napodano, Massimo ;
de Brito, Fabio Sandoli ;
Kodali, Susheel ;
Norgaard, Bjarne L. ;
Hansson, Nicolaj C. ;
Pache, Gregor ;
Canovas, Sergio J. ;
Zhang, Hongbin ;
Leon, Martin B. ;
Webb, John G. ;
Leipsic, Jonathon .
CIRCULATION, 2013, 128 (03) :244-253
[3]   Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation Impact of Device and Annulus Discongruence [J].
Detaint, Delphine ;
Lepage, Laurent ;
Himbert, Dominique ;
Brochet, Eric ;
Messika-Zeitoun, David ;
Iung, Bernard ;
Vahanian, Alec .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :821-827
[4]   Three-Dimensional Echocardiography in Paravalvular Aortic Regurgitation Assessment after Transcatheter Aortic Valve Implantation [J].
Goncalves, Alexandra ;
Almeria, Carlos ;
Marcos-Alberca, Pedro ;
Feltes, Gisela ;
Hernandez-Antolin, Rosana ;
Rodriguez, Enrique ;
Silva Cardoso, Jose C. ;
Macaya, Carlos ;
Luis Zamorano, Jose .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (01) :47-55
[5]  
Gray H, 1918, HEART GRAYS ANATOMY
[6]   Aortic valve calcium scoring is a predictor of significant paravalvular aortic insufficiency in transapical-aortic valve implantation [J].
Haensig, Martin ;
Lehmkuhl, Lukas ;
Rastan, Ardawan Julian ;
Kempfert, Joerg ;
Mukherjee, Chirojit ;
Gutberlet, Matthias ;
Holzhey, David Michael ;
Mohr, Friedrich Wilhelm .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (06) :1234-1241
[7]   Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation [J].
Hayashida, Kentaro ;
Bouvier, Erik ;
Lefevre, Thierry ;
Hovasse, Thomas ;
Morice, Marie-Claude ;
Chevalier, Bernard ;
Romano, Mauro ;
Garot, Philippe ;
Mylotte, Darren ;
Farge, Arnaud ;
Donzeau-Gouge, Patrick ;
Cormier, Bertrand .
EUROINTERVENTION, 2012, 8 (05) :546-555
[8]   A revised methodology for aortic-valvar complex calcium quantification for transcatheter aortic valve implantation [J].
Jilaihawi, Hasan ;
Makkar, Raj R. ;
Kashif, Mohammad ;
Okuyama, Kazuaki ;
Chakravarty, Tarun ;
Shiota, Takahiro ;
Friede, Gerald ;
Nakamura, Mamoo ;
Doctor, Niraj ;
Rafique, Asim ;
Shibayama, Kentaro ;
Mihara, Hirotsugu ;
Trento, Alfredo ;
Cheng, Wen ;
Friedman, John ;
Berman, Daniel ;
Fontana, Gregory P. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (12) :1324-1332
[9]   Cross-Sectional Computed Tomographic Assessment Improves Accuracy of Aortic Annular Sizing for Transcatheter Aortic Valve Replacement and Reduces the Incidence of Paravalvular Aortic Regurgitation [J].
Jilaihawi, Hasan ;
Kashif, Mohammad ;
Fontana, Gregory ;
Furugen, Azusa ;
Shiota, Takahiro ;
Friede, Gerald ;
Makhija, Rakhee ;
Doctor, Niraj ;
Leon, Martin B. ;
Makkar, Raj R. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (14) :1275-1286
[10]  
Kappetein AP, 2012, J AM COLL CARDIOL, V60, P1438, DOI [10.1093/ejcts/ezs533, 10.1016/j.jacc.2012.09.001]