Effect of pupil dilation on biometric measurements and intraocular lens power calculations in schoolchildren

被引:15
作者
Wang, Xiaogang [1 ]
Dong, Jing [2 ]
Tang, Maolong [3 ]
Wang, Xiaoliang [4 ]
Wang, Haitao [1 ]
Zhang, Suhua [1 ]
机构
[1] Shanxi Eye Hosp, Taiyuan, Shanxi, Peoples R China
[2] Shanxi Med Univ, Hosp 1, Taiyuan, Shanxi, Peoples R China
[3] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[4] Shanghai Jiao Tong Univ, Sch Aeronaut & Astronaut, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
AXIAL LENGTH; PARAMETERS; ANTERIOR; ACCOMMODATION; CYCLOPLEGIA; REFRACTION; POSITION;
D O I
10.1371/journal.pone.0203677
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate the effect of pupil dilation on ocular biometric parameters and intraocular lens (IOL) power calculation in schoolchildren using the Lenstar LS 900. Methods One hundred forty eyes of 140 healthy schoolchildren were included in the analysis. Axial length (AL), central corneal thickness (CCT), aqueous depth (AD), anterior chamber depth (ACD), lens thickness (LT), flat keratometry (K), steep K, astigmatism, white-to-white (WTW), and iris/pupil barycenter distance were measured, before and after pupil dilation. Anterior segment length (ASL) was defined as the sum of ACD and LT, and lens position (LP) was defined as ACD plus half of the LT. The relative lens position (RLP) was defined as LP divided by AL. IOL power was calculated using the eight formulas (Hill-RBF, Barrett, Haigis, Hoffer Q, Holladay, Olsen, SRK II, and SRK/T) integrated in the Lenstar LS 900. Parameters before and after pupil dilation were compared. Results AL, AD, ACD, LT, ASL, LP, RLP, flat K, iris barycenter distance, pupil barycenter distance, and PD differed significantly after pupil dilation (P < 0.001 in all cases), as compared to before dilation. The Olsen formula demonstrated significant differences in the magnitude of astigmatism (P = 0.010) and IOL power (P = 0.003) after pupil dilation. Using the different formulas, 23.6 +/- 40.7% of participants had IOL power changes of more than 0.50 diopters, while 0.7 +/- 1.4% had IOL changes of more than 1.0 diopter after pupil dilation. Conclusions Dilated and undilated pupil size affected the Lenstar LS 900 measurement of some ocular biometric parameters, and pupil dilation led to IOL power changes exceeding 0.50 diopters with a high percentage (from 23.6% to 40.7%) in schoolchildren, which should be noticed in clinical practice.
引用
收藏
页数:10
相关论文
共 26 条
[1]   Effect of pharmacological pupil dilation on measurements and iol power calculation made using the new swept-source optical coherence tomography-based optical biometer [J].
Arriola-Villatobos, P. ;
Almendral-Gomez, J. ;
Garzon, N. ;
Ruiz-Medrano, J. ;
Fernandez-Perez, C. ;
Martinez-de-la-Casa, J. M. ;
Diaz-Valled, D. .
JOURNAL FRANCAIS D OPHTALMOLOGIE, 2016, 39 (10) :859-865
[2]   The Impact of Pupillary Dilation on Intraocular Pressure and Anterior Segment Morphology in Subjects with and without Pseudoexfoliation [J].
Atalay, Eray ;
Tamcelik, Nevbahar ;
Cicik, Mustafa Erdogan .
CURRENT EYE RESEARCH, 2015, 40 (06) :646-652
[3]   The Effect of Pupil Dilation on Biometric Parameters of the Lenstar 900 [J].
Bakbak, Berker ;
Koktekir, Bengu E. ;
Gedik, Sansal ;
Guzel, Huseyin .
CORNEA, 2013, 32 (04) :E21-E24
[4]   Effect of cycloplegia on axial length and anterior chamber depth measurements in children [J].
Cheung, Sin Wan ;
Chan, Rufina ;
Cheng, Roy C. S. ;
Cho, Pauline .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (06) :476-481
[5]   Lens Position Parameters as Predictors of Intraocular Pressure Reduction After Cataract Surgery in Glaucomatous Versus Nonglaucomatous Eyes [J].
Coh, Paul ;
Moghimi, Sasan ;
Chen, Rebecca I. ;
Hsu, Chi-Hsin ;
Masis Solano, Marisse ;
Porco, Travis ;
Lin, Shan C. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (06) :2593-2599
[6]   Comparison of 9 intraocular lens power calculation formulas [J].
Cooke, David L. ;
Cooke, Timothy L. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1157-1164
[7]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[8]   Anterior Segment Biometry during Accommodation Imaged with Ultralong Scan Depth Optical Coherence Tomography [J].
Du, Chixin ;
Shen, Meixiao ;
Li, Ming ;
Zhu, Dexi ;
Wang, Michael R. ;
Wang, Jianhua .
OPHTHALMOLOGY, 2012, 119 (12) :2479-2485
[9]   Pupil center shift relative to the coaxially sighted corneal light reflex under natural and pharmacologically dilated conditions [J].
Erdem, Uzeyir ;
Muftuoglu, Orkun ;
Gundogan, Fatih Cakir ;
Sobaci, Gungor ;
Bayer, Atilla .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (05) :530-538
[10]   Effect of pupil dilation on the accuracy of the IOLMaster [J].
Heatley, CJ ;
Whitefield, LA ;
Hugkulstone, CE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11) :1993-1996