The loading patterns of a short femoral stem in total hip arthroplasty: gait analysis at increasing walking speeds and inclines

被引:6
作者
Wiik, Anatole V. [1 ]
Brevadt, Mads [1 ]
Johal, Hardeep [1 ]
Logishetty, Kartik [1 ]
Boughton, Oliver [1 ]
Aqil, Adeel [1 ]
Cobb, Justin P. [1 ]
机构
[1] Charing Cross Hosp, Dept Surg & Canc, MSK Lab, Imperial Coll London, Fulham Palace Rd, London W6 8RF, England
关键词
Gait; Treadmill; Weight acceptance; Hip arthroplasty; REPLACEMENT; COMPONENT; LENGTH; KNEE;
D O I
10.1186/s10195-018-0504-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to examine the gait pattern of total hip arthroplasty (THA) patients with a new short femoral stem at different speeds and inclinations. A total of 40 unilateral THA patients were tested on an instrumented treadmill. They comprised two groups (shorter stemmed THA n = 20, longer stemmed THA n = 20), both which had the same surgical posterior approach. The shorter femoral stemmed patients were taken from an ongoing hip trial with minimum 12 months postop. The comparative longer THR group with similar disease and severity were taken from a gait database along with a demographically similar group of healthy controls (n = 35). All subjects were tested through their entire range of gait speeds and inclines with ground reaction forces collected. Body weight scaling was applied and a symmetry index to compare the implanted hip to the contralateral normal hip. An analysis of variance with significance set at alpha = 0.05 was used. The experimental groups were matched demographically and implant groups for patient reported outcome measures and radiological disease. Both THA groups walked slower than controls, but symmetry at all intervals for all groups were not significantly different. Push-off loading was less favourable for both the shorter and longer stemmed THR groups (p < 0.05) depending on speed. Irrespective of femoral stem length, symmetry for ground reaction forces for both THA groups were returned to a normal range when compared to controls. However individual implant performance showed inferior (p < 0.05) push-off forces and normalised step length in both THR groups when compared to controls. III.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Femoral stem subsidence in cementless total hip arthroplasty: a retrospective single-centre study
    Ries, Christian
    Boese, Christoph Kolja
    Dietrich, Florian
    Miehlke, Wolfgang
    Heisel, Christian
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (02) : 307 - 314
  • [32] Survival of cemented short Exeter femoral components in primary total hip arthroplasty
    van Veghel, Mirthe H. W.
    van Der Koelen, Remy E.
    Hannink, Gerjon
    Schreurs, B. W.
    Rijnen, Wim H. C.
    BONE & JOINT JOURNAL, 2024, 106B (03) : 137 - 142
  • [33] CORR Insights®: Gait Analysis Reveals that Total Hip Arthroplasty Increases Power Production in the Hip During Level Walking and Stair Climbing
    Rylander, Jonathan H.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (08) : 1848 - 1850
  • [34] The NANOS short stem in total hip arthroplasty: a mid term follow-up
    Ettinger, Max
    Ettinger, Peter
    Lerch, Matthias
    Radtke, Kerstin
    Budde, Stefan
    Ezechieli, Marco
    Becher, Christoph
    Thorey, Fritz
    HIP INTERNATIONAL, 2011, 21 (05) : 583 - 586
  • [35] Learning Curve for Short-Stem Total HIP Arthroplasty through an Anterolateral Approach
    Bischofreiter, Martin
    Koelblinger, Christina
    Stumpner, Thomas
    Gruber, Michael Stephan
    Gattringer, Michael
    Kindermann, Harald
    Mattiassich, Georg
    Ortmaier, Reinhold
    MEDICINA-LITHUANIA, 2023, 59 (05):
  • [36] Femoroacetabular offset restoration in total hip arthroplasty; Digital templating a short stem vs a conventional stem
    de Waard, Sheryl
    Verboom, Tom
    Bech, Niels Hendrik
    Sierevelt, Inger N.
    Kerkhoffs, Gino M.
    Haverkamp, Daniel
    WORLD JOURNAL OF ORTHOPEDICS, 2022, 13 (02): : 139 - 149
  • [37] Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty
    Schmidutz, Florian
    Beirer, Marc
    Weber, Patrick
    Mazoochian, Farhad
    Fottner, Andreas
    Jansson, Volkmar
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (07) : 1341 - 1347
  • [38] Risk factors for femoral stem fracture following total hip arthroplasty: a systematic review and meta analysis
    Turnbull, Gareth S.
    Soete, Sam
    Akhtar, Muhammad Adeel
    Ballantyne, James Anderson
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2421 - 2428
  • [39] Biomechanics of a collum-fixated short stem in total hip arthroplasty
    Onneland, Anders Tj
    Nielsen, Poul Torben
    Jakobsen, Thomas
    JOURNAL OF ORTHOPAEDICS, 2024, 52 : 61 - 66
  • [40] CCD and offset after Nanos short stem in total hip arthroplasty
    Ettinger, M.
    Ettinger, P.
    Ezechieli, M.
    Bueermann, S.
    Budde, S.
    Calliess, T.
    Petri, M.
    Thorey, F.
    TECHNOLOGY AND HEALTH CARE, 2013, 21 (02) : 149 - 155