The loading patterns of a short femoral stem in total hip arthroplasty: gait analysis at increasing walking speeds and inclines

被引:6
|
作者
Wiik, Anatole V. [1 ]
Brevadt, Mads [1 ]
Johal, Hardeep [1 ]
Logishetty, Kartik [1 ]
Boughton, Oliver [1 ]
Aqil, Adeel [1 ]
Cobb, Justin P. [1 ]
机构
[1] Charing Cross Hosp, Dept Surg & Canc, MSK Lab, Imperial Coll London, Fulham Palace Rd, London W6 8RF, England
关键词
Gait; Treadmill; Weight acceptance; Hip arthroplasty; REPLACEMENT; COMPONENT; LENGTH; KNEE;
D O I
10.1186/s10195-018-0504-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to examine the gait pattern of total hip arthroplasty (THA) patients with a new short femoral stem at different speeds and inclinations. A total of 40 unilateral THA patients were tested on an instrumented treadmill. They comprised two groups (shorter stemmed THA n = 20, longer stemmed THA n = 20), both which had the same surgical posterior approach. The shorter femoral stemmed patients were taken from an ongoing hip trial with minimum 12 months postop. The comparative longer THR group with similar disease and severity were taken from a gait database along with a demographically similar group of healthy controls (n = 35). All subjects were tested through their entire range of gait speeds and inclines with ground reaction forces collected. Body weight scaling was applied and a symmetry index to compare the implanted hip to the contralateral normal hip. An analysis of variance with significance set at alpha = 0.05 was used. The experimental groups were matched demographically and implant groups for patient reported outcome measures and radiological disease. Both THA groups walked slower than controls, but symmetry at all intervals for all groups were not significantly different. Push-off loading was less favourable for both the shorter and longer stemmed THR groups (p < 0.05) depending on speed. Irrespective of femoral stem length, symmetry for ground reaction forces for both THA groups were returned to a normal range when compared to controls. However individual implant performance showed inferior (p < 0.05) push-off forces and normalised step length in both THR groups when compared to controls. III.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] The loading patterns of a short femoral stem in total hip arthroplasty: gait analysis at increasing walking speeds and inclines
    Anatole V. Wiik
    Mads Brevadt
    Hardeep Johal
    Kartik Logishetty
    Oliver Boughton
    Adeel Aqil
    Justin P. Cobb
    Journal of Orthopaedics and Traumatology, 2018, 19
  • [2] Resurfacing hip arthroplasty better preserves a normal gait pattern at increasing walking speeds compared to total hip arthroplasty
    Gerhardt, Davey M. J. M.
    Mors, Thijs G. Ter
    Hannink, Gerjon
    van Susante, Job L. C.
    ACTA ORTHOPAEDICA, 2019, 90 (03) : 231 - 236
  • [3] The Effect of Hip Arthroplasty on Osteoarthritic Gait: A Blinded, Prospective and Controlled Gait Study at Fast Walking Speeds
    Aqil, Adeel
    Wiik, Anatole
    Zanotto, Michela
    Manning, Victoria
    Masjedi, Milad
    Cobb, Justin P.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (10) : 2337 - 2341
  • [4] Reproducibility of Femoral Offset Following Short Stem and Straight Stem Total Hip Arthroplasty
    von Roth, Philipp
    Perka, Carsten
    Mayr, Hermann O.
    Preininger, Bernd
    Ziebula, Friedrich
    Matziolis, Georg
    Hube, Robert
    ORTHOPEDICS, 2014, 37 (07) : E678 - E684
  • [5] The biomechanical effect of the collar of a femoral stem on total hip arthroplasty
    Jeon, Insu
    Bae, Ji-Yong
    Park, Jin-Hong
    Yoon, Taek-Rim
    Todo, Mitsugu
    Mawatari, Masaaki
    Hotokebuchi, Takao
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2011, 14 (01) : 103 - 112
  • [6] The impact of reducing the femoral stem length in total hip arthroplasty during gait
    Anatole Vilhelm Wiik
    Adeel Aqil
    Bilal Al-Obaidi
    Mads Brevadt
    Justin Peter Cobb
    Archives of Orthopaedic and Trauma Surgery, 2021, 141 : 1993 - 2000
  • [7] The impact of reducing the femoral stem length in total hip arthroplasty during gait
    Wiik, Anatole Vilhelm
    Aqil, Adeel
    Al-Obaidi, Bilal
    Brevadt, Mads
    Cobb, Justin Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (11) : 1993 - 2000
  • [8] Short femoral stem in total hip arthroplasty: stable fixation and low complication rates in elderly patients
    Morales de Cano, Jaime J.
    Gordo, Christian
    Canosa Areste, Jordi
    HIP INTERNATIONAL, 2017, 27 (04) : 311 - 316
  • [9] Long-term results of short stem total hip arthroplasty in patients with osteonecrosis of the femoral head
    Suksathien, Yingyong
    Suarjui, Jithayut
    Tippimanchai, Thanut
    Suksathien, Rachawan
    Lajuntuk, Bankchart
    Khamphaeng, Sirawitz
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 145 (01)
  • [10] Gait Analysis Reveals that Total Hip Arthroplasty Increases Power Production in the Hip During Level Walking and Stair Climbing
    Queen, Robin M.
    Campbell, James C.
    Schmitt, Daniel
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2019, 477 (08) : 1839 - 1847