Modeling Bias Error in 4D Flow MRI Velocity Measurements

被引:8
|
作者
Rothenberger, Sean M. [1 ]
Zhang, Jiacheng [2 ]
Brindise, Melissa C. [2 ]
Schnell, Susanne [3 ]
Markl, Michael [4 ]
Vlachos, Pavlos P. [1 ,2 ]
Rayz, Vitaliy L. [1 ,2 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[3] Univ Greifswald, Inst Phys, D-17489 Greifswald, Germany
[4] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Velocity measurement; Measurement uncertainty; Mathematical models; Spatial resolution; Numerical models; Fluid flow measurement; Hemodynamics; magnetic resonance velocimetry (MRV); partial volume effects; phase contrast magnetic resonance imaging (PC-MRI); systematic error; WALL SHEAR-STRESS; PHASE-CONTRAST MRI; IN-VIVO; INTRACRANIAL ANEURYSMS; BLOOD-FLOW; PATTERNS; IMAGES;
D O I
10.1109/TMI.2022.3149421
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a model to estimate the bias error of 4D flow magnetic resonance imaging (MRI) velocity measurements. The local instantaneous bias error is defined as the difference between the expectation of the voxel's measured velocity and actual velocity at the voxel center. The model accounts for bias error introduced by the intra-voxel velocity distribution and partial volume (PV) effects. We assess the intra-voxel velocity distribution using a 3D Taylor Series expansion. PV effects and numerical errors are considered using a Richardson extrapolation. The model is applied to synthetic Womersley flow and in vitro and in vivo 4D flow MRI measurements in a cerebral aneurysm. The bias error model is valid for measurements with at least 3.75 voxels across the vessel diameter and signal-to-noise ratio greater than 5. All test cases exceeded this diameter to voxel size ratio with diameters, isotropic voxel sizes, and velocity ranging from 3-15mm, 0.5-1mm, and 0-60cm/s, respectively. The model accurately estimates the bias error in voxels not affected by PV effects. In PV voxels, the bias error is an order of magnitude higher, and the accuracy of the bias error estimation in PV voxels ranges from 67.3% to 108% relative to the actual bias error. The bias error estimated for in vivo measurements increased two-fold at systole compared to diastole in partial volume and non-partial volume voxels, suggesting the bias error varies over the cardiac cycle. This bias error model quantifies 4D flow MRI measurement accuracy and can help plan 4D flow MRI scans.
引用
收藏
页码:1802 / 1812
页数:11
相关论文
共 50 条
  • [21] 4D Flow MRI Pressure Estimation Using Velocity Measurement-Error-Based Weighted Least-Squares
    Zhang, Jiacheng
    Brindise, Melissa C.
    Rothenberger, Sean
    Schnell, Susanne
    Markl, Michael
    Saloner, David
    Rayz, Vitaliy L.
    Vlachos, Pavlos P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (05) : 1668 - 1680
  • [22] Comparison of 4D Flow MRI to 2D Flow MRI in the pulmonary arteries in healthy volunteers and patients with pulmonary hypertension
    Sieren, Malte Maria
    Berlin, Clara
    Oechtering, Thekla Helene
    Hunold, Peter
    Droemann, Daniel
    Barkhausen, Jorg
    Frydrychowicz, Alex
    PLOS ONE, 2019, 14 (10):
  • [23] Accelerated dual-venc 4D flow MRI for neurovascular applications
    Schnell, Susanne
    Ansari, Sameer A.
    Wu, Can
    Garcia, Julio
    Murphy, Ian G.
    Rahman, Ozair A.
    Rahsepar, Amir A.
    Aristova, Maria
    Collins, Jeremy D.
    Carr, James C.
    Markl, Michael
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (01) : 102 - 114
  • [24] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Hoijn Ha
    Hanwook Park
    Journal of Visualization, 2019, 22 : 541 - 553
  • [25] Motion-resolved real-time 4D flow MRI with low-rank and subspace modeling
    Sun, Aiqi
    Zhao, Bo
    Zheng, Yichen
    Long, Yuliang
    Wu, Peng
    Wang, Bei
    Li, Rui
    Wang, He
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (05) : 1839 - 1852
  • [26] Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI
    Rose, Michael J.
    Jarvis, Kelly
    Chowdhary, Varun
    Barker, Alex J.
    Allen, Bradley D.
    Robinson, Joshua D.
    Markl, Michael
    Rigsby, Cynthia K.
    Schnell, Susanne
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (06) : 1673 - 1682
  • [27] Analysis of Left Atrial Flow Velocity Distribution by 4D Flow MRI in Patients With Atrial Fibrillation
    Lee, Daniel C.
    Goldberger, Jeffrey J.
    Fluckiger, Jacob
    Ng, Jason
    Carr, James C.
    Collins, Jeremy D.
    Markl, Michael
    CIRCULATION, 2013, 128 (22)
  • [28] Merging computational fluid dynamics and 4D Flow MRI using proper orthogonal decomposition and ridge regression
    Bakhshinejad, Ali
    Baghaie, Ahmadreza
    Vali, Alireza
    Saloner, David
    Rayz, Vitaliy L.
    D'Souza, Roshan M.
    JOURNAL OF BIOMECHANICS, 2017, 58 : 162 - 173
  • [29] Wall Shear Stress Estimation for 4D Flow MRI Using Navier-Stokes Equation Correction
    Zhang, Jiacheng
    Rothenberger, Sean M.
    Brindise, Melissa C.
    Markl, Michael
    Rayz, Vitaliy L.
    Vlachos, Pavlos P.
    ANNALS OF BIOMEDICAL ENGINEERING, 2022, 50 (12) : 1810 - 1825
  • [30] Quantitative evaluation of pulmonary hypertension using 4D flow MRI: A retrospective study
    Koike, Hirofumi
    Nishimura, Takamasa
    Morikawa, Minoru
    HELIYON, 2024, 10 (10)