Modeling Bias Error in 4D Flow MRI Velocity Measurements

被引:8
|
作者
Rothenberger, Sean M. [1 ]
Zhang, Jiacheng [2 ]
Brindise, Melissa C. [2 ]
Schnell, Susanne [3 ]
Markl, Michael [4 ]
Vlachos, Pavlos P. [1 ,2 ]
Rayz, Vitaliy L. [1 ,2 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Mech Engn, W Lafayette, IN 47907 USA
[3] Univ Greifswald, Inst Phys, D-17489 Greifswald, Germany
[4] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Velocity measurement; Measurement uncertainty; Mathematical models; Spatial resolution; Numerical models; Fluid flow measurement; Hemodynamics; magnetic resonance velocimetry (MRV); partial volume effects; phase contrast magnetic resonance imaging (PC-MRI); systematic error; WALL SHEAR-STRESS; PHASE-CONTRAST MRI; IN-VIVO; INTRACRANIAL ANEURYSMS; BLOOD-FLOW; PATTERNS; IMAGES;
D O I
10.1109/TMI.2022.3149421
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We present a model to estimate the bias error of 4D flow magnetic resonance imaging (MRI) velocity measurements. The local instantaneous bias error is defined as the difference between the expectation of the voxel's measured velocity and actual velocity at the voxel center. The model accounts for bias error introduced by the intra-voxel velocity distribution and partial volume (PV) effects. We assess the intra-voxel velocity distribution using a 3D Taylor Series expansion. PV effects and numerical errors are considered using a Richardson extrapolation. The model is applied to synthetic Womersley flow and in vitro and in vivo 4D flow MRI measurements in a cerebral aneurysm. The bias error model is valid for measurements with at least 3.75 voxels across the vessel diameter and signal-to-noise ratio greater than 5. All test cases exceeded this diameter to voxel size ratio with diameters, isotropic voxel sizes, and velocity ranging from 3-15mm, 0.5-1mm, and 0-60cm/s, respectively. The model accurately estimates the bias error in voxels not affected by PV effects. In PV voxels, the bias error is an order of magnitude higher, and the accuracy of the bias error estimation in PV voxels ranges from 67.3% to 108% relative to the actual bias error. The bias error estimated for in vivo measurements increased two-fold at systole compared to diastole in partial volume and non-partial volume voxels, suggesting the bias error varies over the cardiac cycle. This bias error model quantifies 4D flow MRI measurement accuracy and can help plan 4D flow MRI scans.
引用
收藏
页码:1802 / 1812
页数:11
相关论文
共 50 条
  • [1] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126
  • [2] Automatic 4D Flow MRI Segmentation Using the Standardized Difference of Means Velocity
    Rothenberger, Sean M.
    Patel, Neal M.
    Zhang, Jiacheng
    Schnell, Susanne
    Craig, Bruce A.
    Ansari, Sameer A.
    Markl, Michael
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2023, 42 (08) : 2360 - 2373
  • [3] Optimization of 4D flow MRI velocity field in the aorta with divergence-free smoothing
    Gao, Qi
    Liu, Xingli
    Wang, Hongping
    Wu, Peng
    Jin, Mansu
    Wei, RunJie
    Wang, Wei
    Niu, Zhaozhuo
    Zhao, Shihua
    Li, Fei
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (11-12) : 2237 - 2252
  • [4] Segmentation-Free Velocity Field Super-Resolution on 4D Flow MRI
    Levilly, Sebastien
    Moussaoui, Said
    Serfaty, Jean-Michel
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2024, 33 : 5637 - 5649
  • [5] 4D flow MRI
    Markl, Michael
    Frydrychowicz, Alex
    Kozerke, Sebastian
    Hope, Mike
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1015 - 1036
  • [6] 4D flow MRI applications in congenital heart disease
    Rizk, Judy
    EUROPEAN RADIOLOGY, 2021, 31 (02) : 1160 - 1174
  • [7] Abdominal applications of quantitative 4D flow MRI
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Roldan-Alzate, Alejandro
    Reeder, Scott B.
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3229 - 3250
  • [8] 4D Flow MRI Applications for Aortic Disease
    Burris, Nicholas S.
    Hope, Michael D.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 15 - +
  • [9] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Ha, Hoijn
    Park, Hanwook
    JOURNAL OF VISUALIZATION, 2019, 22 (03) : 541 - 553
  • [10] Influence of Spatial Resolution and Compressed SENSE Acceleration Factor on Flow Quantification with 4D Flow MRI at 3 Tesla
    Pravdivtseva, Mariya S.
    Gaidzik, Franziska
    Berg, Philipp
    Ulloa, Patricia
    Larsen, Naomi
    Jansen, Olav
    Hoevener, Jan-Bernd
    Salehi Ravesh, Mona
    TOMOGRAPHY, 2022, 8 (01) : 457 - 478