摘要
Background Gadolinium-based contrast agents (GBCAs) have been used in magnetic resonance imaging for the past 30 years, where they have significantly improved the effectiveness of imaging studies. However, the increased usage of gadolinium in the medical community has also resulted in unexpected interferences in other laboratory assays. This has been particularly the case in clinical elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS). Methods By conducting ICP-MS interference experiments, we describe how gadolinium interferes with elemental analysis by space charge effect, double charge effect and the creation of polyatomic interferences. Additionally, by reviewing more than a year of reference laboratory data from our laboratory information system, we determined the number of elemental tests cancelled due to gadolinium interference. Results Interference experiments show that gadolinium normally found in GBCAs can interfere with heavy metals, platinum and selenium analysis of biological fluids using ICP-MS. Within one year, our institution's metals laboratory had to cancel 42 selenium serum tests and 19 heavy metal urine panels due to potential interference caused by gadolinium. Conclusions GBCAs will continue to be utilized in hospitals around the world. However, clinical laboratories should be wary of potential interferences caused by GBCAs. Relevant interferences include space charge effect, double charge interference, and the formation of polyatomic interferences caused by gadolinium. These interferences can negatively affect patient care by resulting in cancelled laboratory tests and causing patients to have blood redrawn and analysed at a later date leading to delays in their diagnosis/treatment.
引用
收藏
页码:638 / 645
页数:8
相关论文
共 25 条
  • [1] Urinary Gadolinium Levels After Contrast-Enhanced MRI in Individuals with Normal Renal Function: a Pilot Study
    Alwasiyah, Dalia
    Murphy, Christine
    Jannetto, Paul
    Hogg, Melanie
    Beuhler, Michael C.
    [J]. JOURNAL OF MEDICAL TOXICOLOGY, 2019, 15 (02) : 121 - 127
  • [2] Determination of selenium in serum in the presence of gadolinium with ICP-QQQ-MS
    Bishop, David P.
    Hare, Dominic J.
    Fryer, Fred
    Taudte, Regina V.
    Cardoso, Barbara R.
    Cole, Nerida
    Doble, Philip A.
    [J]. ANALYST, 2015, 140 (08) : 2842 - 2846
  • [3] Pharmacokinetics of gadolinium-based contrast agents
    Czock, D.
    [J]. RADIOLOGE, 2019, 59 (05): : 408 - 412
  • [4] Dynamic reaction cell ICP-MS for determination of total As, Cr, Se and V in complex matrices: Still a challenge? A review
    D'Ilio, Sonia
    Violante, Nicola
    Majorani, Costanza
    Petrucci, Francesco
    [J]. ANALYTICA CHIMICA ACTA, 2011, 698 (1-2) : 6 - 13
  • [5] Severe pseudohypocalcemia after gadolinium-enhanced magnetic resonance angiography
    Doorenbos, CJ
    Ozyilmaz, A
    van Wijnen, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (08) : 817 - 818
  • [6] Biochemical safety profiles of gadolinium-based extracellular contrast agents and nephrogenic systemic fibrosis
    Ersoy, Hale
    Rybicki, Frank J.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (05) : 1190 - 1197
  • [7] FDA Drug Safety Communication, 2018, FDA WARNS GAD BAS CO
  • [8] Georgi JC, 2017, ANAL METHODS-UK, V9, P3464, DOI [10.1039/c7ay00430c, 10.1039/C7AY00430C]
  • [9] Interference of gadolinium-based contrast agents with the measurement of serum creatinine by the Jaffe reaction
    Haylor, J.
    Vickers, M. E.
    Morcos, S. K.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (977) : 438 - 439
  • [10] Interference of magnetic resonance imaging contrast agents with the serum calcium measurement technique using colorimetric reagents
    Lin, J
    Idee, JM
    Port, M
    Diai, A
    Berthommier, C
    Robert, M
    Raynal, I
    Devoldere, L
    Corot, C
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 21 (05) : 931 - 943