Addressing Assumptions for the Use of Non-invasive Cardiac Output Measurement Techniques During Exercise in COPD

被引:4
作者
Perrault, Helene [1 ,2 ]
Richard, Ruddy [2 ,3 ,4 ]
Kapchinsky, Sophia [2 ,5 ]
Baril, Jacinthe [2 ]
Bourbeau, Jean [2 ]
Taivassalo, Tanja [2 ,5 ]
机构
[1] Univ Ottawa, Fac Hlth Sci, Ottawa, ON, Canada
[2] McGill Univ, Ctr Hlth, Montreal Chest Inst, Resp & Epidemiol Clin Res Unit, Montreal, PQ H2W 1S4, Canada
[3] CHU, Dept Sport Med & Funct Explorat, Clermont Ferrand, France
[4] INRA, UMR 1019, Clermont Ferrand, France
[5] McGill Univ, Dept Kinesiol & Phys Educ, Montreal, PQ, Canada
关键词
bioimpedance; exercise testing; soluble gas; ventilation:perfusion; OBSTRUCTIVE PULMONARY-DISEASE; IMPEDANCE CARDIOGRAPH DEVICE; MAXIMAL AEROBIC EXERCISE; HEART-FAILURE PATIENTS; DIRECT FICK METHOD; REBREATHING METHOD; VALIDITY; REST; RELIABILITY;
D O I
10.3109/15412555.2015.1043985
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
The multifactorial functional limitation of COPD increasingly demonstrates the need for an integrated circulatory assessment. In this study cardiac output (Qc) derived from non-inert (CO2-RB), inert (N2O-RB) gas rebreathing approaches and bioimpedance were compared to examine the limitations of currently available non-invasive techniques for exercise Qc determination in patients with chronic lung disease. Thirteen COPD patients (GOLD II-III) completed three constant cycling bouts at 20, 35, and 50% of peak work on two occasions to assess Qc with bioimpedance as well as using CO2-RB and N2O-RB for all exercise tests. Results showed significantly lower Qc using the N2O-RB or end-tidal CO2-derived Qc compared to the PaCO2-derived CO2-RB or the bioimpedance at rest and for all exercise intensities. End-tidal CO2-derived values are however not statistically different from those obtained using inert-gas rebreathing. This study show that in COPD patients, CO2-rebreathing Qc values obtained using PaCO2 contents which account for any gas exchange impairment or inadequate gas mixing are similar to those obtained using thoracic bioimpedance. Alternately, the lower values for N2O rebreathing derived Qc indicates the inability of this technique to account for gas exchange impairment in the computation of Qc. These findings indicate that the choice of a gas rebreathing technique to measure Qc in patients must be dictated by the ability to include in the derived computations a correction for either gas exchange inadequacies and/or a vascular shunt.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 26 条
  • [11] Glantz S, 2002, PRIMER BIOSTATISTICS
  • [12] A REVIEW OF IMPEDANCE CARDIOGRAPHY
    JENSEN, L
    YAKIMETS, J
    TEO, KK
    [J]. HEART & LUNG, 1995, 24 (03): : 183 - 193
  • [13] Jones NL, 1997, CLIN EXERCISE TESTIN
  • [14] CARDIAC-OUTPUT BY REBREATHING IN PATIENTS WITH CARDIOPULMONARY DISEASES
    KALLAY, MC
    HYDE, RW
    SMITH, RJ
    ROTHBARD, RL
    SCHREINER, BF
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1987, 63 (01) : 201 - 210
  • [15] MAHLER DA, 1985, AM REV RESPIR DIS, V131, P73
  • [16] Standardisation of spirometry
    Miller, MR
    Hankinson, J
    Brusasco, V
    Burgos, F
    Casaburi, R
    Coates, A
    Crapo, R
    Enright, P
    van der Grinten, CPM
    Gustafsson, P
    Jensen, R
    Johnson, DC
    MacIntyre, N
    McKay, R
    Navajas, D
    Pedersen, OF
    Pellegrino, R
    Viegi, G
    Wanger, J
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) : 319 - 338
  • [17] Validity of arterialized earlobe blood gases at rest and exercise in normoxia and hypoxia
    Mollard, Pascal
    Bourdillon, Nicolas
    Letournel, Muriel
    Herman, Harold
    Gibert, Stephanie
    Pichon, Aurelien
    Woorons, Xavier
    Richalet, Jean-Paul
    [J]. RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2010, 172 (03) : 179 - 183
  • [18] Influence of respiratory pressure support on hemodynamics and exercise tolerance in patients with COPD
    Oliveira, Cristino Carneiro
    Carrascosa, Claudia Regina
    Borghi-Silva, Audrey
    Berton, Danilo C.
    Queiroga, Fernando, Jr.
    Ferreira, Eloara M. V.
    Nery, Luiz E.
    Neder, J. Alberto
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2010, 109 (04) : 681 - 689
  • [19] Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device
    Richard, R
    Lonsdorfer-Wolf, E
    Charloux, A
    Doutreleau, S
    Buchheit, M
    Oswald-Mammosser, M
    Lampert, E
    Mettauer, B
    Geny, B
    Lonsdorfer, J
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2001, 85 (3-4) : 202 - 207
  • [20] Sackner MA, 1977, MESUREMENT CARDIAC O