Smartphone Application with Virtual Reality Goggles for the Reliable and Valid Measurement of Active Craniocervical Range of Motion

被引:15
作者
Chang, Ke-Vin [1 ,2 ,3 ]
Wu, Wei-Ting [1 ,2 ]
Chen, Mei-Chu [1 ]
Chiu, Yi-Chi [1 ]
Han, Der-Sheng [1 ,2 ,3 ,4 ]
Chen, Chih-Cheng [5 ,6 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Phys Med & Rehabil, Bei Hu Branch, Taipei 10845, Taiwan
[2] Natl Taiwan Univ Hosp, Community & Geriatr Med Res Ctr, Bei Hu Branch, Taipei 10845, Taiwan
[3] Natl Taiwan Univ, Dept Phys Med & Rehabil, Coll Med, Taipei 10048, Taiwan
[4] Natl Taiwan Univ, Hlth Sci & Wellness Ctr, Taipei 10617, Taiwan
[5] Acad Sinica, Inst Biomed Sci, Taipei 11574, Taiwan
[6] Acad Sinica, Taiwan Mouse Clin, Natl Comprehens Mouse Phenotyping & Drug Testing, Taipei 11574, Taiwan
关键词
goniometer; neck; rehabilitation; MEASURING CERVICAL RANGE; NONSPECIFIC NECK PAIN; INTERRATER RELIABILITY; CONCURRENT VALIDITY; GONIOMETER;
D O I
10.3390/diagnostics9030071
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed to determine the intra-rater and inter-rater reliability and validity of a hybrid device, combining virtual reality goggles, a magnetometer and an inclinometer application for smartphones, to measure craniocervical range. Summary of Background Data: Accurate evaluation of craniocervical range of motion is important for early detection of certain diseased conditions and monitoring the progress of interventions. The universal goniometer is widely used for the measurement but it requires experienced practitioners. Whether a combination of virtual reality goggles and smartphone applications can provide the same or better performance compared with the goniometer is still unknown. Methods: Forty-one healthy adults from the department of physical medicine and rehabilitation were recruited for craniocervical range examination (flexion, extension, side-bending to the right or left and rotating to the right or left) by using the hybrid device and universal goniometer. Using the hybrid device, repeated measurements were performed twice by a primary rater and once by a second rater. The primary rater also conducted a measurement using the universal goniometer in the same cohort. The intra-rater and inter-rater reliability (intra-class correlation coefficient (ICC)) were calculated using the two-way random effect model, whereas the validity was examined by the Pearson correlation coefficient and Bland-and-Altman plot. The interval between the first and second sessions of the measurement for intra-rater reliability was set at 30 min. Results: Excellent intra-rater (ICC >= 0.925) and inter-rater (ICC >= 0.880) reliability was noted for the hybrid device. The minimal detectable changes from intra-observer and inter-observer comparisons ranged between 4.12 degrees and 7.42 degrees in all six directions. The Bland-and-Altman plot revealed small mean differences (<= 1.68 degrees) between the hybrid device and universal goniometer. Both instruments had highly correlated measurements of craniocervical motion (r values >= 0.918). Conclusion: For healthy participants, excellent intra-rater and inter-rater reliability was noted for the hybrid device, and the measurements were consistent with the universal goniometer measurements. Future studies are needed to examine whether the device can perform similarly for patients with neck disorders.
引用
收藏
页数:12
相关论文
共 23 条
  • [1] Reliability of the Spin-T cervical goniometer in measuring cervical range of motion in an asymptomatic Indian population
    Agarwal, S
    Allison, GT
    Singer, KP
    [J]. JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2005, 28 (07) : 487 - 492
  • [2] Clinimetric evaluation of active range of motion measures in patients with non-specific neck pain: a systematic review
    de Koning, Chantal H. P.
    van den Heuvel, Sylvia P.
    Staal, J. Bart
    Smits-Engelsman, Bouwien C. M.
    Hendriks, Erik J. M.
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (07) : 905 - 921
  • [3] Farooq MN, 2016, PAK J MED SCI, V32, P457, DOI 10.12669/pjms.322.8747
  • [4] Understanding Bland Altman analysis
    Giavarina, Davide
    [J]. BIOCHEMIA MEDICA, 2015, 25 (02) : 141 - 151
  • [5] The epidemiology of neck pain
    Hoy, D. G.
    Protani, M.
    De, R.
    Buchbinder, R.
    [J]. BEST PRACTICE & RESEARCH IN CLINICAL RHEUMATOLOGY, 2010, 24 (06): : 783 - 792
  • [6] Risk factors for neck pain in office workers: a prospective study
    Hush, Julia M.
    Maher, Chris G.
    Refshauge, Kathryn M.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2006, 7 (1)
  • [7] Cervical complications of rheumatoid arthritis
    Kauppi, MJ
    Barcelos, A
    da Silva, JAP
    [J]. ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (03) : 355 - 358
  • [8] A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
    Koo, Terry K.
    Li, Mae Y.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) : 155 - 163
  • [9] Intra- and Interrater Reliability of Sagittal Spinopelvic Parameters on Full-Spine Radiographs in Adults With Symptomatic Spinal Disorders
    Kyrola, Kati Kristiina
    Salme, Jarvenpaa
    Tuija, Jarviluoma
    Tero, Irmola
    Eero, Kauppinen
    Arja, Hakkinen
    [J]. NEUROSPINE, 2018, 15 (02) : 175 - 181
  • [10] Maksymowych WP, 2006, J RHEUMATOL, V33, P2242