Surface functionalization of a microfluidic biosensor for bacteria detection and identification

被引:1
作者
Boehm, Douglas A. [1 ]
Gottlieb, Philip [2 ]
Hua, Susan Z. [1 ,2 ]
机构
[1] SUNY Buffalo, Dept Mech & Aerosp Engn, Buffalo, NY 14260 USA
[2] SUNY Buffalo, Dept Physiol & Biophys, Buffalo, NY 14214 USA
来源
SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2007, PTS 1 AND 2 | 2007年 / 6529卷
基金
美国国家科学基金会;
关键词
biosensor; immunosensor; microfluidics; impedance; bio-MEMS;
D O I
10.1117/12.714441
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Rapid identification and detection of bacteria is an important issue in environmental and food science. We have developed an impedance-based method to simultaneously identify and detect bacteria in a derivatized microfluidic chamber with monoclonal antibodies. The presence of bacteria in the solution can be selectively recognized and fixed on the chamber wall and detected via impedance change in real time. The optimum reaction time between antibody and bacteria has been estimated using a simple model and evaluated experimentally. Various concentrations of cultured E. coli cells ranging from 10(5) to 10(8) CFU/ml were tested using the biosensor. By taking the advantage of a microfluidic system, the bacteria can be concentrated and accumulated on the chamber wall by continuously perfusing the chamber with bacterial suspension, therefore, enhancing the detection limit of the sensor. Using this approach, the biosensor was able to detect 10(6) CFU/ml E. coli (BL21(DE3)) via five consecutive perfusions. The selectivity of the sensor is demonstrated by testing the antibody reaction for two bacteria stains, E. coli and M. catarrhalis. By derivatizing the chamber walls with specific antibodies, we can clearly identify the bacteria that are specific to the antibodies in the detection chamber. The simplicity of the technique also makes the device portable and ideal for clinical and field applications.
引用
收藏
页数:8
相关论文
共 15 条
[1]   Volume cytometry: Microfluidic sensor for high-throughput screening in real time [J].
Ateya, DA ;
Sachs, F ;
Gottlieb, PA ;
Besch, S ;
Hua, SZ .
ANALYTICAL CHEMISTRY, 2005, 77 (05) :1290-1294
[2]   Simultaneous immunoassay using piezoelectric immunosensor array and robust method [J].
Chu, X ;
Jiang, JH ;
Shen, GL ;
Yu, RQ .
ANALYTICA CHIMICA ACTA, 1996, 336 (1-3) :185-193
[3]   Elements of particle deposition onto nonporous solid surfaces parallel to suspension flows [J].
Epstein, N .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 1997, 14 (04) :323-334
[4]   Piezoelectric crystal for sensing bacteria by immobilizing antibodies on divinylsulphone activated poly-m-aminophenol film [J].
Fung, YS ;
Si, SH ;
Zhu, DR .
TALANTA, 2000, 51 (01) :151-158
[5]   Microscale electronic detection of bacterial metabolism [J].
Gómez, R ;
Bashir, R ;
Bhunia, AK .
SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3) :198-208
[6]   Impedance microbiology-on-a-chip:: Microfluidic bioprocessor for rapid detection of bacterial metabolism [J].
Gómez-Sjöberg, R ;
Morisette, DT ;
Bashir, R .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2005, 14 (04) :829-838
[7]   A DYNAMIC-MODEL FOR RECEPTOR-MEDIATED CELL-ADHESION TO SURFACES [J].
HAMMER, DA ;
LAUFFENBURGER, DA .
BIOPHYSICAL JOURNAL, 1987, 52 (03) :475-487
[8]   Microfluidic actuation using electrochemically generated bubbles [J].
Hua, SZ ;
Sachs, F ;
Yang, DX ;
Chopra, HD .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6392-6396
[9]   Optical flow-cell multichannel immunosensor for the detection of biological warfare agents [J].
Koch, S ;
Wolf, H ;
Danapel, C ;
Feller, KA .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (10-11) :779-784
[10]   A simple model for adsorption kinetics at charged solid-liquid interfaces [J].
Koopal, LK ;
Avena, MJ .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2001, 192 (1-3) :93-107