Image quality assessment of real patient thorax CT images using modulation transfer function and noise power spectrum

被引:2
|
作者
Passand, Zahra [1 ]
Hoeschen, Christoph [1 ]
机构
[1] Otto von Guericke Univ, Inst Med Engn, Fac Elect Engn & Informat Technol, Magdeburg, Germany
来源
MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING | 2020年 / 11312卷
关键词
CT image quality; MTF; NPS;
D O I
10.1117/12.2550073
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Computed tomography (CT) is a medical imaging technique which is widely used in various clinical applications. Since the applied radiation is potentially harmful to humans, the applied doses are carefully monitored during CT image acquisition. On the contrary, the CT image quality is not analyzed or monitored during normal clinical operation. A wide range of parameters such as patient anatomy, implants, cardiac or respiratory motion, pathological tissue variations or an inappropriately configured CT system can affect the image quality. Hence, an automated image quality assessment would be desirable to track the CT image quality in daily clinical routine. In this work, the image noise and spatial resolution were characterized and analyzed in order to determine the image quality. While the image noise was characterized by the noise power spectrum (NPS), the spatial resolution was described by the modulation transfer function (MTF). Both methods were applied to human torso phantom images or real thorax CT images. It was shown that both parameters are useful to distinguish between different image qualities. Lower CT image quality was correlated with higher noise amplitudes (measured by the NPS) and a lower spatial resolution (measured by the MTF). Challenges for future works remain in generating appropriately annotated clinical CT image databases as well as in automatically selecting suitable regions-of-interest within the image.
引用
收藏
页数:6
相关论文
共 43 条
  • [21] Blind Image Quality Assessment For Color Images With Additive Gaussian White Noise Using Standard Deviation
    Lim, Chern-Loon
    Paramesran, Raveendran
    2014 International Symposium on Intelligent Signal Processing and Communication Systems (ISPACS), 2014, : 39 - 41
  • [22] Quantitative Evaluation of Clinical Fluoroscopy Systems: Reproducibility of Temporal Modulation Transfer Function and Temporal Noise Power Spectrum Measurements Using a Rotating Edge Method
    Russ, M.
    Mann, S.
    Richards, T.
    Samei, E.
    MEDICAL PHYSICS, 2019, 46 (06) : E528 - E529
  • [23] Assessment of regional LV function using quantitative analysis of contrast-enhanced power modulation images
    Caiani, EG
    Collins, KA
    Korcarz, CE
    Bednarz, JE
    Lang, RM
    Mor-Avi, V
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 577 - 580
  • [24] Construction of Realistic Liver Phantoms from Patient Images using 3D Printer and Its Application in CT Image Quality Assessment
    Leng, Shuai
    Yu, Lifeng
    Vrieze, Thomas
    Kuhlmann, Joel
    Chen, Baiyu
    McCollough, Cynthia H.
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [25] Appropriate Patient Selection at Abdominal Dual-Energy CT Using 80 kV: Relationship between Patient Size, Image Noise, and Image Quality
    Guimaraes, Luis S.
    Fletcher, Joel G.
    Harmsen, William S.
    Yu, Lifeng
    Siddiki, Hassan
    Melton, Zachary
    Huprich, James E.
    Hough, David
    Hartman, Robert
    McCollough, Cynthia H.
    RADIOLOGY, 2010, 257 (03) : 732 - 742
  • [26] Assessment of drying quality for power transformer during manufacturing process using variation of transfer function
    Akbari, A.
    Firoozi, H.
    Borsi, H.
    Kharezi, M.
    2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2006, : 113 - 116
  • [27] Implementation of Automated Tube Current Modulation in PET/CT: Prospective Selection of a Noise Index and Retrospective Patient Analysis to Ensure Image Quality
    Jackson, James
    Pan, Tinsu
    Tonkopi, Elena
    Swanston, Nancy
    Macapinlac, Homer A.
    Rohren, Eric M.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2011, 39 (02) : 83 - 90
  • [28] Image quality enhancement method for on-orbit remote sensing cameras using invariable modulation transfer function
    Li, Jin
    Liu, Zilong
    OPTICS EXPRESS, 2017, 25 (15): : 17134 - 17149
  • [29] Image Quality Analysis for an Aspheric Toric Apodized Diffractive Intraocular Lens Using Modulation Transfer Function Testing
    Schwiegerling, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)