Anchored Transosseous-Equivalent Versus Anchorless Transosseous Rotator Cuff Repair

被引:20
|
作者
Kilcoyne, Kelly G. [1 ]
Guillaume, Stanley G. [2 ]
Hannan, Catherine V. [2 ]
Langdale, Evan R. [2 ]
Belkoff, Stephen M. [2 ]
Srikumaran, Uma [2 ]
机构
[1] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[2] Johns Hopkins Univ, Dept Orthopaed Surg, 601 North Caroline St, Baltimore, MD 21287 USA
来源
AMERICAN JOURNAL OF SPORTS MEDICINE | 2017年 / 45卷 / 10期
关键词
arthroscopic bone tunnels; biomechanical testing; rotator cuff repair; transosseous equivalent; SUTURE-BRIDGE TECHNIQUE; FULL-THICKNESS TEARS; DOUBLE-ROW FIXATION; SINGLE-ROW; ARTHROSCOPIC REPAIR; RETEAR PATTERNS; BIOMECHANICAL EVALUATION; CLINICAL-OUTCOMES; NO DIFFERENCE; SUPRASPINATUS;
D O I
10.1177/0363546517706136
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The original approach for the repair of torn rotator cuffs involved an open technique with sutures passing through the greater tuberosity and tendon. The development of suture anchors allowed for an all-arthroscopic approach with anchor configurations attempting to re-create a transosseous fixation pattern. Presently, an arthroscopic approach can be combined with a transosseous suture configuration without using anchors. Purpose: To evaluate cyclic loading, ultimate load to failure, and the failure mechanisms of transosseous-equivalent (TOE) repair with anchors and anchorless transosseous (AT) repair of rotator cuff tears. Study Design: Controlled laboratory study. Methods: Supraspinatus tears (25 mm) were created in 20 fresh-frozen, human cadaveric shoulders, which were randomized to TOE or AT repair (10 in each group, paired experimental design). Biomechanical testing was performed with an initial preload, cyclic loading, and load to failure. Optical markers were used to monitor gap formation in 3 planes, and the failure mode was recorded. Paired t tests were used to make comparisons of biomechanical parameters between the groups. Multinomial logistic regression was used to compare failure modes between the groups. Significance was set to .05. Results: The TOE group had a significantly higher mean (+/- SD) ultimate failure load (578.5 +/- 123.8 N) than the AT group (468.7 +/- 150.9 N) (P = .034). The TOE group also had a significantly less mean first-cycle excursion (2.97 +/- 1.97 mm) than the AT group (4.70 +/- 2.04 mm) (P = .046). There were no significant differences between the groups in cyclic elongation or linear stiffness during cyclic loading. Primary modes of failure were a type 2 tendon tear with medial tendon disruption in the TOE group (7/10) and a type 1 tendon tear with lateral tendon disruption in the AT group (6/10). Conclusion: TOE repair resulted in a significantly higher mean failure load compared with AT repair in a cadaveric model. The most common modes of failure were a type 2 tendon tear in the TOE group and a type 1 tendon tear in the AT group. Clinical Relevance: A higher mean failure load in TOE versus AT constructs may come at the cost of a less favorable failure mode adjacent to medial anchors at the musculotendinous junction, potentially making revision difficult.
引用
收藏
页码:2364 / 2371
页数:8
相关论文
共 50 条
  • [41] Arthroscopic Repair of Posterosuperior Rotator Cuff Tears Using a Modified Mason-Allen Suture Technique With a Transosseous-Equivalent Construct: A Technical Note
    Hasler, Julian
    Rashid, Mustafa S.
    Mueller-Lebschi, Julia
    Riede, Ulf
    Zumstein, Matthias A.
    ARTHROSCOPY TECHNIQUES, 2024, 13 (05):
  • [42] Arthroscopic Transosseous Reinsertion of the Rotator Cuff
    Nicholas Matis
    Clemens Hübner
    Erwin Aschauer
    Herbert Resch
    European Journal of Trauma, 2006, 32 (4): : 417 - 427
  • [43] Biomechanical effects of a 2 suture-pass medial inter-implant mattress on transosseous-equivalent rotator cuff repair and considerations for a "technical efficiency ratio"
    Park, Maxwell C.
    Peterson, Alexander
    Patton, John
    McGarry, Michelle H.
    Park, Chong J.
    Lee, Thay Q.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (03) : 361 - 368
  • [44] Arthroscopic rotator cuff techniques: single-row, double-row, and the transosseous equivalent
    Lutton, David M.
    Parsons, Bradford O.
    Flatow, Evan L.
    CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (04): : 349 - 354
  • [45] Long-term results after arthroscopic transosseous rotator cuff repair
    Plachel, Fabian
    Traweger, Andreas
    Vasvary, Imre
    Schanda, Jakob E.
    Resch, Herbert
    Moroder, Philipp
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2019, 28 (04) : 706 - 714
  • [46] Arthroscopic rotator cuff repair using a transosseous knotless anchor (ATOK)
    Sandow, Michael J.
    Schutz, Christine R.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (03) : 527 - 533
  • [47] Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double-Row and Knotless Transosseous-Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study
    Hatta, Taku
    Giambini, Hugo
    Hooke, Alexander W.
    Zhao, Chunfeng
    Sperling, John W.
    Steinmann, Scott P.
    Yamamoto, Nobuyuki
    Itoi, Eiji
    An, Kai-Nan
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (10): : 1973 - 1981
  • [48] The effects of Low-intensity Pulsed Ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model
    Lovric, Vedran
    Ledger, Michael
    Goldberg, Jerome
    Harper, Wade
    Bertollo, Nicky
    Pelletier, Matthew H.
    Oliver, Rema A.
    Yu, Yan
    Walsh, William R.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (02) : 466 - 475
  • [49] The effects of Low-intensity Pulsed Ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model
    Vedran Lovric
    Michael Ledger
    Jerome Goldberg
    Wade Harper
    Nicky Bertollo
    Matthew H. Pelletier
    Rema A. Oliver
    Yan Yu
    William R. Walsh
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 466 - 475
  • [50] Arthroscopic Transosseous Rotator Cuff Repair: Technical Note, Outcomes, and Complications
    Black, Eric M.
    Lin, Albert
    Srikumaran, Uma
    Jain, Nitin
    Freehill, Michael T.
    ORTHOPEDICS, 2015, 38 (05) : E352 - E358